Use of the forced-oscillation technique to estimate spirometry values

被引:6
|
作者
Yamamoto, Shoichiro [1 ]
Miyoshi, Seigo [1 ]
Katayama, Hitoshi [1 ]
Okazaki, Mikio [2 ]
Shigematsu, Hisayuki [2 ]
Sano, Yoshifumi [2 ]
Matsubara, Minoru [3 ]
Hamaguchi, Naohiko [1 ]
Okura, Takafumi [1 ]
Higaki, Jitsuo [1 ]
机构
[1] Ehime Univ, Grad Sch Med, Dept Cardiol Pulmonol Hypertens & Nephrol, Toon, Ehime 7910295, Japan
[2] Ehime Univ, Grad Sch Med, Dept Cardiovasc & Thorac Surg, Toon, Japan
[3] Sumitomo Besshi Hosp, Dept Internal Med, Niihama, Japan
关键词
forced expiratory volume in 1 second; forced-oscillation technique; forced vital capacity; spirometry; vital capacity; INTERSTITIAL LUNG-DISEASE; IMPULSE OSCILLOMETRY; AIRWAY FUNCTION; ASTHMA; DYSFUNCTION; REACTANCE;
D O I
10.2147/COPD.S143721
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Purpose: Spirometry is sometimes difficult to perform in elderly patients and in those with severe respiratory distress. The forced-oscillation technique (FOT) is a simple and noninvasive method of measuring respiratory impedance. The aim of this study was to determine if FOT data reflect spirometric indices. Patients and methods: Patients underwent both FOT and spirometry procedures prior to inclusion in development (n=1,089) and validation (n=552) studies. Multivariate linear regression analysis was performed to identify FOT parameters predictive of vital capacity (VC), forced VC (FVC), and forced expiratory volume in 1 second (FEV1). A regression equation was used to calculate estimated VC, FVC, and FEV1. We then determined whether the estimated data reflected spirometric indices. Agreement between actual and estimated spirometry data was assessed by Bland-Altman analysis. Results: Significant correlations were observed between actual and estimated VC, FVC, and FEV1 values (all r>0.8 and P<0.001). These results were deemed robust by a separate validation study (all r>0.8 and P<0.001). Bias between the actual data and estimated data for VC, FVC, and FEV1 in the development study was 0.007 L (95% limits of agreement [LOA] 0.907 and -0.893 L), -0.064 L (95% LOA 0.843 and -0.971 L), and -0.039 L (95% LOA 0.735 and -0.814 L), respectively. On the other hand, bias between the actual data and estimated data for VC, FVC, and FEV1 in the validation study was -0.201 L (95% LOA 0.62 and -1.022 L), -0.262 L (95% LOA 0.582 and -1.106 L), and -0.174 L (95% LOA 0.576 and -0.923 L), respectively, suggesting that the estimated data in the validation study did not have high accuracy. Conclusion: Further studies are needed to generate more accurate regression equations for spirometric indices based on FOT measurements.
引用
收藏
页码:2859 / 2868
页数:10
相关论文
共 50 条
  • [31] DOES MAXIMAL FORCED EXPIRATORY AND MAXIMAL INSPIRATORY MANOEUVRES OF SPIROMETRY HAVE A SIGNIFICANT IMPACT ON FORCED OSCILLATION TECHNIQUE (FOT)?
    Handley, B. M.
    Thamrin, C.
    Mascarenhas, S. K.
    Schoeffel, R. E.
    King, G. G.
    RESPIROLOGY, 2017, 22 : 12 - 12
  • [32] Comparison of Forced Oscillation Technique and Spirometry for Assessing Airway Obstruction and its Reversibility in Asthmatic Children
    A Colom
    F Navarra
    G Andrada
    C Kofman
    A Teper
    Pediatric Research, 2003, 53 : 874 - 874
  • [33] Correlation of lung function using forced oscillation technique with spirometry in children with cystic fibrosis (CF)
    Singh, Sachin
    Singh, Meenu
    Mathew, Joseph
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [34] COMPARISON OF FORCED OSCILLATION, BODY-PLETHYSMOGRAPHY AND SPIROMETRY
    BUHR, W
    LANDSER, F
    REIMNITZ, P
    BERDEL, D
    ATEMWEGS-UND LUNGENKRANKHEITEN, 1987, 13 (08) : 370 - 374
  • [35] BRONCHODILATOR RESPONSE IN ASTHMA USING THE FORCED OSCILLATION TECHNIQUE IS COMPARABLE TO SPIROMETRY AND RELATES TO ASTHMA CONTROL
    Cottee, A.
    Seccombe, L.
    Thamrin, C.
    King, G.
    Peters, M.
    Farah, C.
    RESPIROLOGY, 2019, 24 : 74 - 74
  • [36] Bronchodilator Responses Of Forced Oscillation Technique And Spirometry In Adults With And Without Airflow Obstruction In An Australian Community
    Jetmalani, K.
    Thamrin, C.
    Farah, C. S.
    Diba, C.
    Toelle, B.
    King, G. G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [37] The dead volume effect on the elastic moduli measurements using the forced-oscillation method
    Mikhaltsevitch, Vassily
    Lebedev, Maxim
    Chavez, Rafael
    Pervukhina, Marina
    Glubokovskikh, Stanislav
    Vargas Jr, Euripedes do Amaral
    GEOPHYSICAL PROSPECTING, 2022, 70 (03) : 547 - 557
  • [38] Forced-oscillation control of sound radiated from the flow around a cascade of flat plates
    Tanaka, Y.
    Yokoyama, H.
    Iida, A.
    JOURNAL OF SOUND AND VIBRATION, 2018, 431 : 248 - 264
  • [39] MEASUREMENT OF RESPIRATORY RESISTANCE BY THE FORCED-OSCILLATION METHOD - VALIDITY IN OTHER THAN NORMAL SUBJECTS
    BOISSINOT, E
    MOLINE, J
    SOUILLE, B
    VARAIGNE, F
    JOURNAL DE PHYSIOLOGIE, 1987, 82 (03): : A1 - A1
  • [40] Overall and peripheral lung function assessment by spirometry and forced oscillation technique in relation to asthma diagnosis and control
    Rentzhog, C. Heijkenskjold
    Janson, C.
    Berglund, L.
    Borres, M. P.
    Nordvall, L.
    Alving, K.
    Malinovschi, A.
    CLINICAL AND EXPERIMENTAL ALLERGY, 2017, 47 (12): : 1546 - 1554