Use of the forced-oscillation technique to estimate spirometry values

被引:6
|
作者
Yamamoto, Shoichiro [1 ]
Miyoshi, Seigo [1 ]
Katayama, Hitoshi [1 ]
Okazaki, Mikio [2 ]
Shigematsu, Hisayuki [2 ]
Sano, Yoshifumi [2 ]
Matsubara, Minoru [3 ]
Hamaguchi, Naohiko [1 ]
Okura, Takafumi [1 ]
Higaki, Jitsuo [1 ]
机构
[1] Ehime Univ, Grad Sch Med, Dept Cardiol Pulmonol Hypertens & Nephrol, Toon, Ehime 7910295, Japan
[2] Ehime Univ, Grad Sch Med, Dept Cardiovasc & Thorac Surg, Toon, Japan
[3] Sumitomo Besshi Hosp, Dept Internal Med, Niihama, Japan
关键词
forced expiratory volume in 1 second; forced-oscillation technique; forced vital capacity; spirometry; vital capacity; INTERSTITIAL LUNG-DISEASE; IMPULSE OSCILLOMETRY; AIRWAY FUNCTION; ASTHMA; DYSFUNCTION; REACTANCE;
D O I
10.2147/COPD.S143721
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Purpose: Spirometry is sometimes difficult to perform in elderly patients and in those with severe respiratory distress. The forced-oscillation technique (FOT) is a simple and noninvasive method of measuring respiratory impedance. The aim of this study was to determine if FOT data reflect spirometric indices. Patients and methods: Patients underwent both FOT and spirometry procedures prior to inclusion in development (n=1,089) and validation (n=552) studies. Multivariate linear regression analysis was performed to identify FOT parameters predictive of vital capacity (VC), forced VC (FVC), and forced expiratory volume in 1 second (FEV1). A regression equation was used to calculate estimated VC, FVC, and FEV1. We then determined whether the estimated data reflected spirometric indices. Agreement between actual and estimated spirometry data was assessed by Bland-Altman analysis. Results: Significant correlations were observed between actual and estimated VC, FVC, and FEV1 values (all r>0.8 and P<0.001). These results were deemed robust by a separate validation study (all r>0.8 and P<0.001). Bias between the actual data and estimated data for VC, FVC, and FEV1 in the development study was 0.007 L (95% limits of agreement [LOA] 0.907 and -0.893 L), -0.064 L (95% LOA 0.843 and -0.971 L), and -0.039 L (95% LOA 0.735 and -0.814 L), respectively. On the other hand, bias between the actual data and estimated data for VC, FVC, and FEV1 in the validation study was -0.201 L (95% LOA 0.62 and -1.022 L), -0.262 L (95% LOA 0.582 and -1.106 L), and -0.174 L (95% LOA 0.576 and -0.923 L), respectively, suggesting that the estimated data in the validation study did not have high accuracy. Conclusion: Further studies are needed to generate more accurate regression equations for spirometric indices based on FOT measurements.
引用
收藏
页码:2859 / 2868
页数:10
相关论文
共 50 条
  • [1] USE OF THE FORCED OSCILLATION TECHNIQUE TO ESTIMATE SPIROMETRY VALUES
    Yamamoto, Shoichiro
    Miyoshi, Seigo
    Katayama, Hitoshi
    Okazaki, Mikio
    Shigematsu, Hisayuki
    Sano, Yoshifumi
    Matsubara, Minoru
    Hamaguchi, Naohiko
    Okura, Takafumi
    Higaki, Jitsuo
    RESPIROLOGY, 2017, 22 : 150 - 151
  • [2] Comparison of forced oscillation technique and spirometry in paediatric asthma
    Lauhkonen, Eero
    Kaltsakas, Georgios
    Sivagnanasithiyar, Sindhu
    Iles, Richard
    ERJ OPEN RESEARCH, 2021, 7 (01)
  • [3] High-frequency respiratory impedance measured by forced-oscillation technique in infants
    Frey, U
    Silverman, M
    Kraemer, R
    Jackson, AC
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (02) : 363 - 370
  • [4] Assessing Decreased Thoracic Compliance With Forced Oscillation Technique and Spirometry
    Khan, Muzna N.
    Rojas, Jose D.
    Branson, Richard D.
    Shah, Syed A.
    Sampson, Catherine M.
    Seeton, Roger
    Rodriquez, Dario
    Kinsky, Michael P.
    RESPIRATORY CARE, 2022, 67 (11) : 1460 - 1464
  • [5] Comparison of bronchodilator responsiveness between forced oscillation technique and spirometry
    Lauhkonen, Eero
    Sivagnanasithiyar, Sindhu
    Kaltsakas, Georgios
    Iles, Richard
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [6] FORCED OSCILLATION TECHNIQUE AND SPIROMETRY IN COLD AIR PROVOCATION TESTS
    WESSELING, GJ
    VANDERHOVENAUGUSTIN, IML
    WOUTERS, EFM
    THORAX, 1993, 48 (03) : 254 - 259
  • [7] Dynamics of a Ring Micromechanical Gyroscope in the Forced-Oscillation Mode
    Martynenko Y.G.
    Merkuriev I.V.
    Podalkov V.V.
    Gyroscopy and Navigation, 2010, 1 (01) : 43 - 51
  • [8] CORRELATION OF FORCED OSCILLATION TECHNIQUE WITH SPIROMETRY IN EVALUATION OF PULMONARY-FUNCTION
    SINHA, R
    ELIRAZ, A
    KIMBEL, P
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1979, 119 (04): : 170 - 170
  • [9] Forced oscillation technique in veterans with preserved spirometry and chronic respiratory symptoms
    Butzko, Ryan P.
    Sotolongo, Anays M.
    Helmer, Drew A.
    Klein-Adams, Jacquelyn C.
    Osinubi, Omowunmi Y.
    Berman, Andrew R.
    Ortiz-Pacheco, Ronaldo
    Falvo, Michael J.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2019, 260 : 8 - 16
  • [10] Comparison of forced oscillation technique (FOT) with spirometry measures in acute asthma
    Almeida, Paula Cristina Andrade
    Aljehani, Mouaid
    Martin, Matthew J.
    Harrison, Tim W.
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62