Optimal design configuration and operating sequencing of hybrid chiller plant: A case study of hotel building in Cairo, Egypt

被引:5
|
作者
Mouneer, Tarek A. [1 ]
Aly, Mohamed H. [2 ]
Mina, Ehab M. [3 ]
机构
[1] Benha Univ, Benha Fac Engn, Mech Engn Dept, Banha, Egypt
[2] Helwan Univ, Fac Engn Mataria, Mech Power Engn Dept, Cairo, Egypt
[3] Ain Shams Univ, Fac Engn, Mech Power Engn Dept, Cairo, Egypt
来源
关键词
Hybrid chiller plant; Hotel building; Chiller sequencing; Building cooling; Building air conditioning; Cairo climate; PERFORMANCE ASSESSMENT; ENERGY PERFORMANCE; EMPIRICAL-MODEL; SOLAR; UNCERTAINTY; OPTIMIZATION; CONSUMPTION; SYSTEMS; CCHP;
D O I
10.1016/j.jobe.2021.102796
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research demonstrates the optimal design option and operating sequencing for hybrid chillers plant which can use two different energy sources. The purpose of the investigation focus on Sofitel Cairo Nile El-Gezirah Hotel, nestled within Al-Zamalek island in Cairo, Egypt, as a case study in current research. Special attention is given to its round facade which gives special characterised cooling load profiles. The study compromises two main design configurations from A.I to A.V with 5 options and from B.I to B.VI with 6 options, to investigate and compare several operating sequences for hybrid chiller plant (HCP) of 4000 TR. The first investigation employs systematic calculation for the initial and running costs of the HCP with design configurations A and B. The second investigation compares their several operating sequences for design configurations A and B. The results of performance parameters such as coefficient of performance for hybrid chiller plant records variations in the running cost using hourly analysis from time 00:00 to 23:59 in response of variation in solar radiation, external loads, and internal loads. Concerning the results of these two analyses, the finding depicts the optimal design configuration, besides the best operating sequence for each design configuration regarding the estimated operational data for each design option and operating sequence under the building applied cooling loads during the summer season with Cairo climate conditions.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Controlling venetian blinds based on parametric design; via implementing Grasshopper's plugins: A case study of an office building in Cairo
    Eltaweel, Ahmad
    Su, Yuehong
    ENERGY AND BUILDINGS, 2017, 139 : 31 - 43
  • [32] Research on influences of wall design on embodied and operating energy consumption: A case study of temporary building in China
    Song, Yiming
    Zhang, Hong
    Mithraratne, Nalanie
    ENERGY AND BUILDINGS, 2023, 278
  • [33] Optimal Design of Hybrid Energy System with PV/Wind Turbine/Storage: A Case Study
    Huang, Rui
    Low, Steven H.
    Topcu, Ufuk
    Chandy, K. Mani
    Clarke, Christopher R.
    2011 IEEE INTERNATIONAL CONFERENCE ON SMART GRID COMMUNICATIONS (SMARTGRIDCOMM), 2011,
  • [34] Optimal Design of Hybrid Renewable Energy System Using HOMER: A Case Study in the Philippines
    Lin, Chin E.
    Phan, Bao Chau
    Lai, Ying-Chih
    2019 IEEE SOUTHEASTCON, 2019,
  • [35] Effects of Reliability Index on Optimal Configuration of Hybrid Solar/Battery Energy System by Optimization Approach: A Case Study
    Liu, Hao
    Wu, Baojia
    Maleki, Akbar
    Pourfayaz, Fathollah
    Ghasempour, Roghayeh
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2021, 2021
  • [36] hybrid Model Using MCDM Methods and Bipolar Neutrosophic Sets for Select Optimal Wind Turbine: Case Study in Egypt
    Abdel-Monem A.
    Gawad A.A.
    Abdel-Monem, Ahmed (ahmed.abdelmon3m15@gmail.com); Gawad, Amal Abdel (amgawad2001@yahoo.com), 1600, University of New Mexico (42): : 1 - 27
  • [37] Environmental and hydraulic design of thermal power plants outfalls "Case study: Banha Thermal Power Plant, Egypt''
    Shawky, Yasser
    Nada, Ahmed M.
    Abdelhaleem, Fahmy Salah
    AIN SHAMS ENGINEERING JOURNAL, 2013, 4 (03) : 333 - 342
  • [38] Modified Farmland Fertility Optimization Algorithm for Optimal Design of a Grid-connected Hybrid Renewable Energy System with Fuel Cell Storage: Case Study of Ataka, Egypt
    Diab, Ahmed A. Zaki
    EL-Ajmi, Sultan, I
    Sultan, Hamdy M.
    Hassan, Yahia B.
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2019, 10 (08) : 119 - 132
  • [39] Exploiting exergy and exergoeconomic analysis as decisional tool for cogeneration plant optimal operating mode: A sugar factory case study
    Sharew, Shumet Sendek
    Di Pretoro, Alessandro
    Yimam, Abubeker
    Negny, Stephane
    Montastruc, Ludovic
    ENERGY REPORTS, 2024, 12 : 143 - 157
  • [40] A multi-objective life cycle approach for optimal building design: A case study in Finnish context
    Pal, Sudip Kumar
    Takano, Atsushi
    Alanne, Kari
    Palonen, Matti
    Siren, Kai
    JOURNAL OF CLEANER PRODUCTION, 2017, 143 : 1021 - 1035