Optimal design configuration and operating sequencing of hybrid chiller plant: A case study of hotel building in Cairo, Egypt

被引:5
|
作者
Mouneer, Tarek A. [1 ]
Aly, Mohamed H. [2 ]
Mina, Ehab M. [3 ]
机构
[1] Benha Univ, Benha Fac Engn, Mech Engn Dept, Banha, Egypt
[2] Helwan Univ, Fac Engn Mataria, Mech Power Engn Dept, Cairo, Egypt
[3] Ain Shams Univ, Fac Engn, Mech Power Engn Dept, Cairo, Egypt
来源
关键词
Hybrid chiller plant; Hotel building; Chiller sequencing; Building cooling; Building air conditioning; Cairo climate; PERFORMANCE ASSESSMENT; ENERGY PERFORMANCE; EMPIRICAL-MODEL; SOLAR; UNCERTAINTY; OPTIMIZATION; CONSUMPTION; SYSTEMS; CCHP;
D O I
10.1016/j.jobe.2021.102796
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research demonstrates the optimal design option and operating sequencing for hybrid chillers plant which can use two different energy sources. The purpose of the investigation focus on Sofitel Cairo Nile El-Gezirah Hotel, nestled within Al-Zamalek island in Cairo, Egypt, as a case study in current research. Special attention is given to its round facade which gives special characterised cooling load profiles. The study compromises two main design configurations from A.I to A.V with 5 options and from B.I to B.VI with 6 options, to investigate and compare several operating sequences for hybrid chiller plant (HCP) of 4000 TR. The first investigation employs systematic calculation for the initial and running costs of the HCP with design configurations A and B. The second investigation compares their several operating sequences for design configurations A and B. The results of performance parameters such as coefficient of performance for hybrid chiller plant records variations in the running cost using hourly analysis from time 00:00 to 23:59 in response of variation in solar radiation, external loads, and internal loads. Concerning the results of these two analyses, the finding depicts the optimal design configuration, besides the best operating sequence for each design configuration regarding the estimated operational data for each design option and operating sequence under the building applied cooling loads during the summer season with Cairo climate conditions.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] A Case Analysis on Energy Savings and Efficiency Improvement of a Chiller Plant in a Luxury Hotel Building
    Anandh, N.
    Kumar, P.
    INTERNATIONAL ENERGY JOURNAL, 2021, 21 (04): : 447 - 456
  • [2] Web Based Chiller Plant Optimal Control-A Case Study
    Ma, Keyan
    Zhao, Tianyi
    Shen, Dandan
    Liu, Mingsheng
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 967 - 974
  • [3] Effects of nightlife activities on urban spaces and design: a case study of Cairo, Egypt
    Elshater A.
    Abusaada H.
    City, Territory and Architecture, 9 (1)
  • [4] Procedure to obtain the optimal distribution cooling capacity of an air-condensed chiller plant for a hotel facility conceptual design
    Torres, Yamile Diaz
    Calvo, Roy Reyes
    Herrera, Hernan Hernandez
    Guerra, Mario A. Alvarez
    Sarduy, Julio Gomez
    Ortega, Jorge Ivan Silva
    ENERGY REPORTS, 2021, 7 : 622 - 637
  • [5] A Case Study of Analyzing Energy Use and Equivalent Carbon Footprint in an Educational Building in Cairo, Egypt
    Afifi, Mohamed A.
    Fathy, Fatma
    Hamza, Hussein
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON WATER ENERGY FOOD AND SUSTAINABILITY, ICOWEFS 2023, 2024, : 223 - 232
  • [6] Predicting energy consumption of chiller plant using WOA-BiLSTM hybrid prediction model: A case study for a hospital building
    Song, Yang
    Xie, Hui
    Zhu, Zhengwei
    Ji, Ru
    ENERGY AND BUILDINGS, 2023, 300
  • [7] Comparative energy performance simulation for passive and conventional design: A case study in Cairo, Egypt
    Mahmoud, S.
    Fahmy, M.
    Mahdy, M.
    Elwy, I
    Abdelalim, M.
    ENERGY REPORTS, 2020, 6 : 699 - 704
  • [8] Investigation of the optimal location design of a hybrid wind-solar plant: A case study
    Rezaei, Mostafa
    Mostafaeipour, Ali
    Qolipour, Mojtaba
    Tauakkoli-Moghaddam, Reza
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (01) : 100 - 114
  • [9] Optimum configuration of a dispatchable hybrid renewable energy plant using artificial neural networks: Case study of Ras Ghareb, Egypt
    Hamdi, Mohamed
    Salmawy, Hafez A. El
    Ragab, Reda
    AIMS ENERGY, 2023, 11 (01) : 171 - 196
  • [10] Design and Energy Performance Analysis of a Hotel Building in a Hot and Dry Climate: A Case Study
    Kobeyev, Sultan
    Tokbolat, Serik
    Durdyev, Serdar
    ENERGIES, 2021, 14 (17)