Impact of scar burden by single-photon emission computed tomography myocardial perfusion imaging on patient outcomes following cardiac resynchronization therapy

被引:139
|
作者
Adelstein, Evan C. [1 ]
Tanaka, Hidekazu [1 ]
Soman, Prem [1 ]
Miske, Glen [1 ]
Haberman, Stephanie C. [1 ]
Saba, Samir F. [1 ]
Gorcsan, John, III [1 ]
机构
[1] Univ Pittsburgh, Cardiovasc Inst, Pittsburgh, PA 15213 USA
关键词
Heart failure; Pacing; Imaging; Nuclear medicine; Echocardiography; HEART-FAILURE PATIENTS; DOPPLER-ECHOCARDIOGRAPHIC EVIDENCE; NARROW QRS COMPLEXES; VENTRICULAR DYSSYNCHRONY; ISCHEMIC CARDIOMYOPATHY; PREDICTS RESPONSE; AMERICAN-SOCIETY; WRITING GROUP; GATED SPECT; TISSUE;
D O I
10.1093/eurheartj/ehq389
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Ischaemic heart disease negatively impacts response to cardiac resynchronization therapy (CRT), yet the impact of infarct scar burden on clinical outcomes and its interaction with mechanical dyssynchrony have not been well described. Methods and results We studied 620 NYHA classes III-IV heart failure patients with ejection fraction (EF) <= 35% and QRS duration >= 120 ms referred for CRT. Included were 190 ischaemic cardiomyopathy (ICM) CRT recipients with scar burden quantified by rest-redistribution Tl(201) myocardial perfusion imaging using a 17-segment (0 normal to 4 absence of uptake) summed rest score (SRS). Non-ICM (NICM) CRT recipients (n = 380) and 50 patients referred for CRT with unsuccessful LV lead implant comprised the comparison groups. Echocardiographic dyssynchrony analysis was performed in a subgroup of 150 patients. Follow-up left ventricular EF (LVEF) and volumes were examined at 7 +/- 3 months in 143 patients. The outcome of death, cardiac transplant, or mechanical circulatory support was assessed in all. Over 2.1 +/- 1.6 years, ICM patients had significantly worse survival and less LVEF improvement than NICM patients (P < 0.01). Ischaemic cardiomyopathy patients with low scar burden (SRS < 27) had favourable survival and LVEF improvement, similar to NICM patients. A high scar burden (SRS >= 27) was associated with reduced survival and lack of LV functional improvement (P <= 0.01), similar to those with unsuccessful LV lead implant, whereas baseline dyssynchrony was not predictive of outcome in these patients. Conclusion Extensive scar burden in ICM patients unfavourably affected clinical and LV functional outcomes after CRT, regardless of baseline dyssynchrony measures. Patients with ICM and lower scar burden had significantly better outcomes, similar to NICM patients.
引用
收藏
页码:93 / 103
页数:11
相关论文
共 50 条
  • [1] Impact of cardiac size on diagnostic performance of single-photon emission computed tomography myocardial perfusion imaging: insights from the REgistry of Fast Myocardial Perfusion Imaging with NExt generation single-photon emission computed tomography
    Randazzo, Michael
    Elias, Pierre
    Poterucha, Timothy
    Sharir, Tali
    Fish, Matthews
    Ruddy, Terrence
    Kaufmann, Philipp
    Sinusas, Albert
    Miller, Edward
    Bateman, Timothy
    Dorbala, Sharmila
    Di Carli, Marcelo
    Castillo, Michelle
    Liang, Joanna
    Miller, Robert
    Dey, Damini
    Berman, Daniel
    Slomka, Piotr
    Einstein, Andrew
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (07) : 996 - 1006
  • [2] Sequential single-photon emission computed tomography myocardial perfusion imaging
    Shaw, LJ
    Berman, DS
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (8A): : 28J - 39J
  • [3] Cardiac Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging Finally Up to Speed?
    Wackers, Frans J. Th.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (18) : 1975 - 1978
  • [4] Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice
    Wu, MC
    Gao, DW
    Sievers, RE
    Lee, RJ
    Hasegawa, BH
    Dae, MW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (03) : 576 - 582
  • [5] Attenuation correction single-photon emission computed tomography myocardial perfusion imaging
    Bateman, TM
    Cullom, SJ
    SEMINARS IN NUCLEAR MEDICINE, 2005, 35 (01) : 37 - 51
  • [6] Single-photon emission computed tomography myocardial perfusion imaging in patients with diabetes
    Noble G.L.
    Heller G.V.
    Current Cardiology Reports, 2005, 7 (2) : 117 - 123
  • [7] Impact of Positron Emission Tomography Viability Imaging: Guided Revascularizations on Clinical Outcomes in Patients With Myocardial Scar on Single-Photon Emission Computed Tomography Scans
    Park, Jong Sung
    Lee, Jang Hoon
    Hong, Chae Moon
    Park, Bo Eun
    Park, Yoon Jung
    Kim, Hong Nyun
    Kim, Namkyun
    Jang, Se Yong
    Bae, Myung Hwan
    Yang, Dong Heon
    Park, Hun Sik
    Cho, Yongkeun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2023, 38 (46)
  • [8] Impact of Appropriate Use on the Prognostic Value of Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging
    Doukky, Rami
    Hayes, Kathleen
    Frogge, Nathan
    Balakrishnan, Gautam
    Dontaraju, Venkata Satish
    Rangel, Maria O.
    Golzar, Yasmeen
    Garcia-Sayan, Enrique
    Hendel, Robert C.
    CIRCULATION, 2013, 128 (15) : 1634 - 1643
  • [9] Assessment of myocardial viability using single-photon emission computed tomography myocardial perfusion imaging
    Malhotra, Saurabh
    Gomez, Javier
    Doukky, Rami
    CURRENT OPINION IN CARDIOLOGY, 2019, 34 (05) : 473 - 483
  • [10] Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan
    Takayuki Shibutani
    Koichi Okuda
    Hajime Ichikawa
    Toyohiro Kato
    Kenta Miwa
    Hiroyuki Tsushima
    Masahisa Onoguchi
    Akio Nagaki
    Japanese Journal of Radiology, 2020, 38 : 274 - 282