An automated ECG-artifact removal method for trunk muscle surface EMG recordings

被引:57
|
作者
Mak, Joseph N. F. [1 ]
Hu, Yong [1 ]
Luk, Keith D. K. [1 ]
机构
[1] Univ Hong Kong, Dept Orthopaed & Traumatol, Hong Kong, Hong Kong, Peoples R China
关键词
Surface EMG; ECG artifact; ICA; Automated; INDEPENDENT COMPONENT ANALYSIS; EVENT-SYNCHRONOUS CANCELLATION; DYNAMIC CONTRACTIONS; MYOELECTRIC SIGNALS; INTERFERENCE; EEG; CONTAMINATION; IDENTIFICATION; ELIMINATION; ALGORITHMS;
D O I
10.1016/j.medengphy.2010.05.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) correspond to ECG artifact were then identified by an automated detection algorithm and subsequently removed. The detection performance of the algorithm was compared to that by visual inspection, while the artifact elimination performance was compared with Butterworth high pass filter at 30 Hz cutoff (BW HPF 30). The automated ECG-artifact detection algorithm successfully recognized the ECG source components in all data sets with a sensitivity of 100% and specificity of 99%. Better performance indicated by a significantly higher correlation coefficient (p < 0.001) with the original EMG recordings was found in the SEMG data cleaned by the ICA-based method, than that by BW HPF 30. The automated ECG-artifact removal method for trunk SEMG recordings proposed in this study was demonstrated to produce a very good detection rate and preserved essential EMG components while keeping its distortion to minimum. The automatic nature of our method has solved the problem of visual inspection by standard ICA methods and brings great clinical benefits. (c) 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:840 / 848
页数:9
相关论文
共 50 条
  • [1] ECG Artifact Removal from Surface EMG Signal Using an Automated Method Based on Wavelet-ICA
    Abbaspour, Sara
    Linden, Maria
    Gholamhosseini, Hamid
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON WEARABLE MICRO AND NANO TECHNOLOGIES FOR PERSONALIZED HEALTH (PHEALTH 2015), 2015, 211 : 91 - 97
  • [2] ECG Artifact Removal from EMG Recordings using Independent Component Analysis and Adapted Filter
    Li, Yun
    Chen, Xiang
    Zhang, Xu
    Zhou, Ping
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 347 - 350
  • [3] ECG artifact removal from surface EMG using adaptive filter algorithm
    Yeom, H. (hyeom@eulji.ac.kr), 1600, Science and Engineering Research Support Society, Room 402, Man-Je Bld., 449-8, Ojung-Dong, Daedoek-Gu, Korea, Republic of (07):
  • [4] Improving EEG Muscle Artifact Removal With an EMG Array
    Mucarquer, Juan Andres
    Prado, Pavel
    Escobar, Maria-Jose
    El-Deredy, Wael
    Zanartu, Matias
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (03) : 815 - 824
  • [5] REMOVAL OF ECG ARTIFACT FROM EEG IN BRAIN DEATH AND OTHER RECORDINGS
    BERGER, EL
    STOCKARD, JJ
    AUNG, MH
    BICKFORD, RG
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1974, 37 (02): : 202 - 203
  • [6] Adaptive filtering for ECG rejection from surface EMG recordings
    Marque, C
    Bisch, C
    Dantas, R
    Elayoubi, S
    Brosse, V
    Pérot, C
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (03) : 310 - 315
  • [7] Trunk muscle onset detection technique for EMG signals with ECG artefact
    Allison, GT
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (03) : 209 - 216
  • [8] ECG ARTIFACT REMOVAL FROM SURFACE EMG SIGNALS BY COMBINING EMPIRICAL MODE DECOMPOSITION AND INDEPENDENT COMPONENT ANALYSIS
    Taelman, Joachim
    Mijovic, Bogdan
    Van Huffel, Sabine
    Devuyst, Stephanie
    Dutoit, Thierry
    BIOSIGNALS 2011, 2011, : 421 - +
  • [9] Estimated ECG Subtraction method for removing ECG artifacts in esophageal recordings of diaphragm EMG
    Jonkman, Annemijn H.
    Juffermans, Ricardo
    Doorduin, Jonne
    Heunks, Leo M. A.
    Harlaar, Jaap
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 69
  • [10] A Novel Method for Automatic Identification of Motion Artifact Beats in ECG Recordings
    Yuewen Tu
    Xiuquan Fu
    Dingli Li
    Chao Huang
    Yawei Tang
    Shuming Ye
    Hang Chen
    Annals of Biomedical Engineering, 2012, 40 : 1917 - 1928