Discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters

被引:177
|
作者
West, Adam G. [1 ,2 ]
Goldsmith, Gregory R. [2 ]
Brooks, Paul D. [3 ]
Dawson, Todd E. [2 ,3 ]
机构
[1] Univ Cape Town, Dept Bot, ZA-7701 Rondebosch, South Africa
[2] Univ Calif Berkeley, Dept Integrat Biol, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Ctr Stable Isotope Biogeochem, Berkeley, CA 94720 USA
基金
美国安德鲁·梅隆基金会;
关键词
RING-DOWN SPECTROSCOPY; INTRASPECIFIC VARIATION; RESOURCE AVAILABILITY; LEAF WATER; PRECISION; HYDROGEN; SAMPLES; DELTA-O-18; CELLULOSE; EXCHANGE;
D O I
10.1002/rcm.4597
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of isotope ratio infrared spectroscopy (IRIS) for the stable hydrogen and oxygen isotope analysis of water is increasing. While IRIS has many advantages over traditional isotope ratio mass spectrometry (IRMS), it may also be prone to errors that do not impact upon IRMS analyses. Of particular concern is the potential for contaminants in the water sample to interfere with the spectroscopy, thus leading to erroneous stable isotope data. Water extracted from plant and soil samples may often contain organic contaminants. The extent to which contaminants may interfere with IRIS and thus impact upon data quality is presently unknown. We tested the performance of IRIS relative to IRMS for water extracted from 11 plant species and one organic soil horizon. IRIS deviated considerably from IRMS for over half of the samples tested, with deviations as large as 46 parts per thousand (delta(2)H) and 15.4 parts per thousand (delta(18)O) being measured. This effect was reduced somewhat by using activated charcoal to remove organics from the water; however, deviations as large as 35 parts per thousand (delta(2)H) and 11.8 parts per thousand (delta(18)O) were still measured for these cleaned samples. Interestingly, the use of activated charcoal to clean water samples had less effect than previously thought for IRMS analyses. Our data show that extreme caution is required when using IRIS to analyse water samples that may contain organic contaminants. We suggest that the development of new cleaning techniques for removing organic contaminants together with instrument-based software to flag potentially problematic samples are necessary to ensure accurate plant and soil water analyses using IRIS. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1948 / 1954
页数:7
相关论文
共 50 条
  • [31] Protein Stable Isotope Fingerprinting: Multidimensional Protein Chromatography Coupled to Stable Isotope-Ratio Mass Spectrometry
    Mohr, Wiebke
    Tang, Tiantian
    Sattin, Sarah R.
    Bovee, Roderick J.
    Pearson, Ann
    ANALYTICAL CHEMISTRY, 2014, 86 (17) : 8514 - 8520
  • [32] Pretreatment method for oxygen stable isotope ratio analysis of the sugar-rich fraction in fruit juice via isotope ratio mass spectrometry
    Watanabe, Ayano
    Terada, Shoichi
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (22)
  • [33] Comparison of catabolic rates of fatty acids using stable isotope and isotope-ratio mass spectrometry
    Gotoh, Naohiro
    Nagai, Toshiharu
    Yoshinaga, Kazuaki
    Mizobe, Hoyo
    Watanabe, Hiroyuki
    Lipid Technology, 2013, 25 (05) : 110 - 112
  • [34] Long-term performance of the Gasbench isotope ratio mass spectrometry system for the stable isotope analysis of carbonate microsamples
    Spoetl, Christoph
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (11) : 1683 - 1685
  • [35] STABLE ISOTOPE RATIO MASS-SPECTROMETRY FOR IRON BIOAVAILABILITY STUDIES
    EAGLES, J
    FAIRWEATHERTAIT, SJ
    SELF, R
    ANALYTICAL CHEMISTRY, 1985, 57 (02) : 469 - 471
  • [36] Stable isotope ratio mass spectrometry in global climate change research
    Ghosh, P
    Brand, WA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 228 (01) : 1 - 33
  • [37] Origin of pigments in eggs traced by stable isotope ratio mass spectrometry
    Department of Food Science, Hebei North University, Zhangjiakou
    Hebei, China
    不详
    Hebei, China
    Mod. Food Sci. Technol., 9 (250-255):
  • [38] Isotope ratio monitoring gas chromatography mass spectrometry of D H by high temperature conversion isotope ratio mass spectrometry
    Hilkert, AW
    Douthitt, CB
    Schlüter, HJ
    Brand, WA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (13) : 1226 - 1230
  • [39] Carbon Isotope Ratio Analysis of Steroids by High-Temperature Liquid Chromatography-Isotope Ratio Mass Spectrometry
    Zhang, Lijun
    Thevis, Mario
    Piper, Thomas
    Jochmann, Maik A.
    Wolbert, J. Benjamin
    Kujawinski, Dorothea M.
    Wiese, Steffen
    Teutenberg, Thorsten
    Schmidt, Torsten C.
    ANALYTICAL CHEMISTRY, 2014, 86 (05) : 2297 - 2302
  • [40] Differential mobility spectrometry-mass spectrometry for isotope ratio analysis
    Ayodeji, Ifeoluwa
    Evans-Nguyen, Theresa
    Badal, Sunil
    MacLean, Garett
    Shelley, Jacob
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257