Optimization of reactants relative humidity for high performance of polymer electrolyte membrane fuel cells with co-flow and counter-flow configurations

被引:29
|
作者
Wang, Yulin [1 ]
Wang, Shixue [2 ]
Liu, Shengchun [1 ]
Li, Hua [3 ]
Zhu, Kai [1 ]
机构
[1] Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin 300134, Peoples R China
[2] Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ene, MOE, Tianjin 300350, Peoples R China
[3] Kyushu Univ, Grad Sch Engn, Dept Hydrogen Energy Syst, Fukuoka 8190395, Japan
基金
中国国家自然科学基金;
关键词
PEM fuel cell; Water management; Relative humidity; Co-flow and counter-flow configurations; Cell performance; PROTON-EXCHANGE MEMBRANE; HIGH-CURRENT DENSITY; PEMFC PERFORMANCE; MICROPOROUS LAYER; GAS-DIFFUSION; CATHODE; MODEL; TEMPERATURE; SIMULATION; UNIFORMITY;
D O I
10.1016/j.enconman.2019.112369
中图分类号
O414.1 [热力学];
学科分类号
摘要
A three-dimensional multiphase polymer electrolyte membrane (PEM) fuel cell model is employed to investigate the membrane and liquid water transport property as well as cell performance with the co-flow and counter-flow configurations under different reactant relative humidity (RH) conditions. Numerical results indicate that a lower anode RH with a cathode RH of 100% or a lower cathode RH with an anode RH of 100% leads to a decrement in cell performance at high operational voltages and an increment in cell performance at low operational voltages. With moderate or high anode and cathode RH, the liquid water saturation in porous electrodes is the limiting factor in cell performance improvement; but with low anode and cathode RH, the membrane water content becomes the limiting factor. Moreover, the counter-flow configuration shows differences in the membrane and liquid water distributions in comparison with the co-flow configuration. This study also found that the counter-flow configuration with the anode and cathode RH of 50% greatly increases the current density by 21.21% compared with the co-flow configuration under the anode and cathode RH of 100% at the operational voltage of 0.4 V, therefore, the counter-flow configuration with moderate anode and cathode RH is recommended for the optimal operation of a parallel flow field PEM fuel cell.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effect of time-varying humidity on the performance of polymer electrolyte membrane fuel cells
    Noorani, Shamsuddin
    Shamim, Tariq
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (10) : 1223 - 1231
  • [22] Characterization of bipolar plate-free polymer electrolyte membrane fuel cells operating in low and high relative humidity
    Park, Gyutae
    Kim, Gyuhyeon
    Yang, Seonghyeon
    So, Yoonho
    Kwon, Obeen
    Park, Junghyun
    Oh, Hyoun-Myoung
    Baek, Jiwon
    Jang, Hojae
    Park, Taehyun
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2024, 131 : 240 - 247
  • [23] Experimental analysis of internal gas flow configurations for a polymer electrolyte membrane fuel cell stack
    Friedl, A.
    Fraser, S. D.
    Baumgartner, Wr.
    Hacker, V.
    JOURNAL OF POWER SOURCES, 2008, 185 (01) : 248 - 260
  • [24] Effect of flow pattern of gas and cooling water on relative humidity distribution in polymer electrolyte fuel cell
    Inoue, Gen
    Yoshimoto, Takashi
    Matsukuma, Yosuke
    Minemoto, Masaki
    Itoh, Hideki
    Tsurumaki, Shigeru
    JOURNAL OF POWER SOURCES, 2006, 162 (01) : 94 - 104
  • [25] High performance nitrile copolymers for polymer electrolyte membrane fuel cells
    Kim, Dae Sik
    Kim, Yu Seung
    Guiver, Michael D.
    Pivovar, Bryan S.
    JOURNAL OF MEMBRANE SCIENCE, 2008, 321 (02) : 199 - 208
  • [26] Application of porous materials for the flow field in polymer electrolyte membrane fuel cells
    Zhang, Yinghui
    Tao, Youkun
    Shao, Jing
    JOURNAL OF POWER SOURCES, 2021, 492
  • [27] Experimental investigation of polymer electrolyte membrane fuel cells with ramification flow fields
    Weng, F-B
    Hsu, C-Y
    Su, A.
    Chan, S-H
    Lin, C-Y
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2008, 222 (A8) : 771 - 779
  • [28] Application of Carbon Felt as a Flow Distributor for Polymer Electrolyte Membrane Fuel Cells
    Lee, Hojin
    Kim, Hyecheol
    Kim, Hansung
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (02) : F74 - F78
  • [29] Gas Flow Sputtering of Catalyst Layers for Polymer Electrolyte Membrane Fuel Cells
    Vasic, Stanislav
    Guenther, Bernd H.
    CHEMIE INGENIEUR TECHNIK, 2012, 84 (12) : 2204 - 2209
  • [30] Enhanced diffusion in polymer electrolyte membrane fuel cells using oscillating flow
    Hwang, Yong-Sheen
    Lee, Dae-Young
    Choi, Jong Won
    Kim, Seo-Young
    Cho, Sung Ho
    Joonho, Park
    Kim, Min Soo
    Jang, Jae Hyuk
    Kim, Sung Han
    Cha, Suk-Won
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (08) : 3676 - 3683