Optimization of reactants relative humidity for high performance of polymer electrolyte membrane fuel cells with co-flow and counter-flow configurations

被引:29
|
作者
Wang, Yulin [1 ]
Wang, Shixue [2 ]
Liu, Shengchun [1 ]
Li, Hua [3 ]
Zhu, Kai [1 ]
机构
[1] Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin 300134, Peoples R China
[2] Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ene, MOE, Tianjin 300350, Peoples R China
[3] Kyushu Univ, Grad Sch Engn, Dept Hydrogen Energy Syst, Fukuoka 8190395, Japan
基金
中国国家自然科学基金;
关键词
PEM fuel cell; Water management; Relative humidity; Co-flow and counter-flow configurations; Cell performance; PROTON-EXCHANGE MEMBRANE; HIGH-CURRENT DENSITY; PEMFC PERFORMANCE; MICROPOROUS LAYER; GAS-DIFFUSION; CATHODE; MODEL; TEMPERATURE; SIMULATION; UNIFORMITY;
D O I
10.1016/j.enconman.2019.112369
中图分类号
O414.1 [热力学];
学科分类号
摘要
A three-dimensional multiphase polymer electrolyte membrane (PEM) fuel cell model is employed to investigate the membrane and liquid water transport property as well as cell performance with the co-flow and counter-flow configurations under different reactant relative humidity (RH) conditions. Numerical results indicate that a lower anode RH with a cathode RH of 100% or a lower cathode RH with an anode RH of 100% leads to a decrement in cell performance at high operational voltages and an increment in cell performance at low operational voltages. With moderate or high anode and cathode RH, the liquid water saturation in porous electrodes is the limiting factor in cell performance improvement; but with low anode and cathode RH, the membrane water content becomes the limiting factor. Moreover, the counter-flow configuration shows differences in the membrane and liquid water distributions in comparison with the co-flow configuration. This study also found that the counter-flow configuration with the anode and cathode RH of 50% greatly increases the current density by 21.21% compared with the co-flow configuration under the anode and cathode RH of 100% at the operational voltage of 0.4 V, therefore, the counter-flow configuration with moderate anode and cathode RH is recommended for the optimal operation of a parallel flow field PEM fuel cell.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Three-dimensional Modeling of Gas Purge in a Polymer Electrolyte Membrane Fuel Cell with Co-flow and Counter-flow Pattern
    Xu, Peng
    Xu, Sichuan
    FUEL CELLS, 2017, 17 (06) : 794 - 808
  • [2] Numerical and experimental comparative study of microfluidic fuel cells with different flow configurations: Co-flow vs. counter-flow cell
    Wang, Yifei
    Leung, Dennis Y. C.
    Zhang, Hao
    Xuan, Jin
    Wang, Huizhi
    APPLIED ENERGY, 2017, 203 : 535 - 548
  • [3] Optimization of gas feeding operations for polymer electrolyte membrane fuel cell with the co-flow feeding gas mode
    Shao, Yangbin
    Xu, Liangfei
    Xu, Ling
    Tai, Shupeng
    Hu, Zunyan
    Dai, Wei
    Li, Jianqiu
    Shen, Tong
    Ouyang, Minggao
    2020 CHINESE AUTOMATION CONGRESS (CAC 2020), 2020, : 4019 - 4023
  • [4] Modelica based modelling and thermodynamic analysis of co-flow and counter-flow solid oxide fuel cell system
    Xia, Lei
    Hua, Qingsong
    Nizetic, Sandro
    Sun, Li
    ENERGY CONVERSION AND MANAGEMENT, 2024, 317
  • [5] Innovative flow field design strategies for performance optimization in polymer electrolyte membrane fuel cells
    Choi, Jaeyoo
    Park, Yooseong
    Park, Jihoon
    Kim, Chanyoung
    Heo, Seongku
    Kim, Sun-Dong
    Ju, Hyunchul
    APPLIED ENERGY, 2025, 377
  • [6] Optimization of Parallel and Serpentine Configurations for Polymer Electrolyte Membrane Fuel Cells
    Guo, N.
    Leu, M. C.
    Koylu, U. O.
    FUEL CELLS, 2014, 14 (06) : 876 - 885
  • [7] Performance experimental data of a polymer electrolyte fuel cell considering the variation of the relative humidity of reactants gases
    Espinoza-Andaluz, Mayken
    Santana, Jordy
    Li, Tingshuai
    Andersson, Martin
    DATA IN BRIEF, 2019, 27
  • [8] Numerical Investigation of Tapered Flow Field Configurations for Enhanced Polymer Electrolyte Membrane Fuel Cell Performance
    Wang, Yulin
    Wang, Xiaoai
    Fan, Yuanzhi
    He, Wei
    Guan, Jinglei
    Wang, Xiaodong
    APPLIED ENERGY, 2022, 306
  • [9] Study on counter-flow mass transfer characteristics and performance optimization of commercial large-scale proton exchange membrane fuel cells
    Lu, Guolong
    Liu, Mingxin
    Su, Xunkang
    Zheng, Tongxi
    Luan, Yang
    Fan, Wenxuan
    Cui, Hao
    Liu, Zhenning
    APPLIED ENERGY, 2024, 359
  • [10] Relative humidity control in polymer electrolyte membrane fuel cells without extra humidification
    Riascos, Luis A. M.
    JOURNAL OF POWER SOURCES, 2008, 184 (01) : 204 - 211