Purpose: To perform 4D dose calculations using a feedback‐controlled treatment couch in 15 lung and abdominal patients Methods: Fifteen patients undergoing 4D CT were considered in this work. The GTV was delineated on ten 3D CT data sets by independent experts, with a planning margin added corresponding to the 2σ deviation from the mean center‐of‐mass. Tumor trajectories were derived from 4D CT data and fitted to a Fourier series expansion. Intra‐ and inter‐fraction statistical variations in amplitude and period were applied by considering literature estimates of the standard deviations. The couch feedback control system was simulated using second‐order couch dynamics and a first‐order controller. The residual tumor trajectory was calculated by inputting the tumor trajectory to the control system. A 7‐beam IMRT plan was generated on the end‐exhale CT with a prescription dose of 66 Gy. The resulting 4D dose distribution was calculated by sampling the isocenter position along the continuous tumor trajectory before and after motion compensation using a previously published Monte Carlo algorithm. Results: The mean tumor motion amplitude was 11.4±3.4 (SD) mm. After compensation the amplitude was 0.42±0.23 mm. Degradation of the tumor dose up to 35% was observed. After compensation, an average of 18.8 ± 4.7% improvement in the 100% dose coverage was seen for end inhale, and 13.4 ± 4.7% for the 90% coverage. For the combined 4D dose, GTV dose coverage was 94.7±4.7% (for 100% coverage) after compensation, but degraded to 87.3±4.5% without compensation. Conclusion: We have developed a framework for performing 4D dose calculations using real‐time tumor trajectories. For IMRT plans, the average improvement in the dose coverage to the PTV for mobile tumors with a feedback‐controlled couch was X% Conflict of Interest: Supported by 3DLine Medical Systems. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2368 / 2369
页数:2
相关论文
共 50 条
  • [1] Development of a four-dimensional Monte Carlo dose calculation system for real-time tumor-tracking irradiation with a gimbaled X-ray head
    Ishihara, Yoshitomo
    Nakamura, Mitsuhiro
    Miyabe, Yuki
    Mukumoto, Nobutaka
    Matsuo, Yukinori
    Sawada, Akira
    Kokubo, Masaki
    Mizowaki, Takashi
    Hiraoka, Masahiro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 35 : 59 - 65
  • [2] Investigation of four-dimensional (4D) Monte Carlo dose calculation in real-time tumor tracking stereotatic body radiotherapy for lung cancers
    Chan, Mark K. H.
    Kwong, Dora L. W.
    Ng, Sherry C. Y.
    Tam, Eric K. W.
    Tong, Anthony S. M.
    MEDICAL PHYSICS, 2012, 39 (09) : 5479 - 5487
  • [3] Automated four-dimensional Monte Carlo workflow using log files and real-time motion monitoring
    Sibolt, P.
    Cronholm, R. O.
    Heath, E.
    Andersen, C. E.
    Behrens, C. F.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [4] Real four-dimensional Monte Carlo dose calculation for double-dynamic systems (time-dependent delivery under organ motion)
    Paganetti, H
    Rietzel, E
    Can, A
    Singh, H
    Chen, GTY
    MEDICAL PHYSICS, 2003, 30 (06) : 1451 - 1451
  • [5] Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
    Shirato, H
    Shimizu, S
    Kitamura, K
    Nishioka, T
    Kagei, K
    Hashimoto, S
    Aoyama, H
    Kunieda, T
    Shinohara, N
    Dosaka-Akita, H
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02): : 435 - 442
  • [6] Real-time tumor-tracking and four-dimensional radiotherapy
    Shirato, H. (shirato@med.hokudai.ac.jp), 1600, Institute of Electronics Information and Communication Eng., Annex 3F, 5-22, Shibakoen 3 chome, Minato-ku, Tokyo, 105-0011, Japan (96):
  • [7] Towards real-time photon Monte Carlo dose calculation in the cloud
    Ziegenhein, Peter
    Kozin, Igor N.
    Kamerling, Cornelis Ph
    Oelfke, Uwe
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11): : 4375 - 4389
  • [8] Real-time hybrid Monte Carlo for dose calculation in proton therapy
    Ibanez, P.
    Valladolid, V.
    Villa-Abaunza, A.
    Espinosa, A.
    Arias, F.
    Galve, P.
    Sanchez-Parcerisa, D.
    Udias, J. M.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1532 - S1533
  • [9] Monte Carlo as a four-dimensional radiotherapy treatment-planning tool to account for respiratory motion
    Keall, PJ
    Siebers, JV
    Joshi, S
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (16): : 3639 - 3648
  • [10] A Hybrid Monte-Carlo sampling smoother for four-dimensional data assimilation
    Attia, Ahmed
    Rao, Vishwas
    Sandu, Adrian
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2017, 83 (01) : 90 - 112