Association of Ambulatory Blood Pressure Monitoring parameters with the Framingham Stroke Risk Profile

被引:5
|
作者
Tsivgoulis, Georgios [1 ]
Pikilidou, Maria [2 ]
Katsanos, Aristeidis H. [1 ,3 ]
Stamatelopoulos, Kimon [4 ]
Michas, Fotios [4 ]
Lykka, Aikaterini [4 ]
Zompola, Christina [1 ]
Filippatou, Angeliki [1 ]
Boviatsis, Efstathios [5 ]
Voumvourakis, Konstantinos [1 ]
Zakopoulos, Nikolaos [4 ]
Manios, Efstathios [4 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Med, Attikon Hosp, Dept Neurol 2, Athens, Greece
[2] Aristotle Univ Thessaloniki, AHEPA Univ Hosp, Dept Internal Med 1, Hypertens Excellence Ctr, Thessaloniki, Greece
[3] Univ Ioannina, Dept Neurol, Sch Med, Ioannina, Greece
[4] Natl & Kapodistrian Univ Athens, Sch Med, Dept Clin Therapeut, Athens, Greece
[5] Natl & Kapodistrian Univ Athens, Sch Med, Attikon Hosp, Dept Neurosurg, Athens, Greece
关键词
Stroke prevention; Systolic blood pressure; Diastolic blood pressure; Ambulatory blood pressure monitoring; Framingham stroke risk profile; PREDICTS CARDIOVASCULAR EVENTS; WHITE-COAT HYPERTENSION; PULSE PRESSURE; ARTERIAL STIFFNESS; REVERSE-DIPPER; HEART-RATE; VARIABILITY; VALIDATION; INFARCTION; PROGNOSIS;
D O I
10.1016/j.jns.2017.07.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The Framingham Stroke Risk Profile (FSRP) is a novel and reliable tool for estimating the 10-year probability for incident stroke in stroke-free individuals, while the predictive value of ambulatory blood pressure monitoring (ABPM) for first-ever and recurrent stroke has been well established. We sought to evaluate cross-sectionally the association of ABPM parameters with FSRP score in a large sample of 2343 consecutive stroke-free individuals (mean age: 56.0 +/- 12.9, 49.1% male) who underwent 24-hour ABPM. True hypertensives showed significantly higher FSRP (11.2 +/- 5.0) compared to the normotensives (8.2 +/- 5.0, p <0.001), while subjects with white coat hypertension also had higher FSRP (102 4.7) than normotensives (8.2 +/- 5.0, p < 0.001). Compared to dippers that exhibited the lowest FSRP, non-dippers and reverse-dippers exhibited significantly higher FSRP (9.8 +/- 4.8 for dippers vs 10.6 +/- 52 and 11.5 +/- 5.0 for non-dippers and reverse -dippers respectively, p 0.001 for comparisons). In univariate analyses, the ABPM parameters that had the strongest correlation with FSRP were 24 hour (r = 0.440, p < 0.001), daytime (r = 0.435, p < 0.001) and night-time (r = 0.423; p <0.001) pulse pressure (PP). The best fitting model for predicting FSRP (R-2 = 24.6%) on multiple linear regression analyses after adjustment for vascular risk factors not included in FSRP comprised the following parameters in descending order: 24 hour PP (beta = 0.349, p < 0.001), daytime SBP variability (beta = 0.124, p < 0.001), 24-hour HR variability (beta = 0.091, p < 0.001), mean 24 -hour HR (beta = 0.107, p <0.001), BMI (beta = 0.081, p <0.001) and dipping percentage (beta = 0.063, p = 0.001). 24-hour PP and daytime SBP variability are the two ABPM parameters that were more strongly associated with FSRP-score. Reverse dippers had the highest FSRP among all dipping status profiles. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 50 条
  • [21] Ambulatory blood pressure monitoring in acute stroke: the importance of time rate of blood pressure variation
    Zis, Panagiotis
    Spengos, Konstantinos
    Manios, Efstathios
    Vemmos, Konstantinos
    Zis, Vassilios
    Dimopoulos, Meletios-Athanasios
    Zakopoulos, Nikolaos
    BLOOD PRESSURE MONITORING, 2012, 17 (05) : 220 - 221
  • [22] Ambulatory blood pressure monitoring in acute stroke: pathophysiology of the time rate of blood pressure variation and association with the 1-year outcome
    Zis, Panagiotis
    Vemmos, Konstantinos
    Spengos, Konstantinos
    Manios, Efstathios
    Zis, Vassilios
    Dimopoulos, Meletios-Athanasios
    Zakopoulos, Nikolaos
    BLOOD PRESSURE MONITORING, 2013, 18 (02) : 94 - 100
  • [23] Ambulatory blood pressure (ABP) and cardiovascular risk profile in coronaropatics
    Restori, G
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 183A - 183A
  • [24] 24 hour ambulatory blood pressure monitoring during and following stroke
    Nussinovitch, N
    Elkayam, A
    Peleg, E
    Katz, A
    Rosenthal, T
    AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (05) : 168A - 169A
  • [25] ACUTE ISCHEMIC STROKE DURING AMBULATORY BLOOD-PRESSURE MONITORING
    NUNES, JP
    FARIA, MD
    POLONIA, JJ
    LANCET, 1992, 339 (8801): : 1113 - 1114
  • [26] Ambulatory blood pressure monitoring and stroke - More questions than answers
    Lip, GYH
    Gibbs, CR
    Beevers, DG
    STROKE, 1998, 29 (08) : 1495 - 1497
  • [27] THE FRAMINGHAM STROKE RISK PROFILE PREDICTS THE PROBABILITY OF STROKE RECURRENCE
    WOLF, PA
    DAGOSTINO, RB
    BELANGER, AJ
    KELLYHAYES, M
    KASE, CS
    KANNEL, WB
    STROKE, 1992, 23 (01) : 160 - 160
  • [28] Correlation between Previous Stroke History and Ambulatory Blood Pressure Parameters after Stroke
    Hong, C. Y.
    Wang, Z. X.
    Zang, D. W.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2023, 71 : S38 - S39
  • [29] Blood pressure variability and arterial stiffness parameters derived from ambulatory blood pressure monitoring
    Kikuya, Masahiro
    Asayama, Kei
    Ohkubo, Takayoshi
    KARDIOLOGIA POLSKA, 2019, 77 (05) : 509 - 514
  • [30] Ambulatory blood pressure monitoring
    Head, Geoffrey A.
    McGrath, Barry P.
    Mihailidou, Anastasia S.
    Nelson, Mark R.
    Schlaich, Markus P.
    Mangoni, Arduino A.
    Cowley, Diane
    Wilson, Alison
    AUSTRALIAN FAMILY PHYSICIAN, 2011, 40 (11) : 877 - 880