Thermal calibration of heated silicon atomic force microscope cantilevers

被引:0
|
作者
Nelson, Brent A. [1 ]
King, William P. [2 ]
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Univ Illinois, Dept Mech Sci & Engn, Urbana, IL USA
关键词
heated atomic force microscopy; thermal cantilever; nanomanufacturing; microheater;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper analyzes the accuracy and stability of calibration methodologies for heated silicon atomic force microscope cantilevers. The calibration techniques include Raman thermometry, comparison of the cantilever electrical characteristics with theory, and isothermal calibration on a hotplate. The various techniques offer tradeoffs between calibration time and calibration accuracy, where the best accuracy possible is with Raman thermometry, which calibrates the heater temperature to within 3-10% of the temperature rise, depending upon the temperature. The temperature calibrations are stable with storage time and cantilever usage, although a 'burn-in' period is usually required to stabilize the cantilever resistance.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Temperature calibration of heated silicon atomic force microscope cantilevers
    Nelson, B. A.
    King, W. P.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2007, 140 (01) : 51 - 59
  • [2] Calibration of silicon atomic force microscope cantilevers
    Gibson, CT
    Smith, DA
    Roberts, CJ
    [J]. NANOTECHNOLOGY, 2005, 16 (02) : 234 - 238
  • [3] Calibration of rectangular atomic force microscope cantilevers
    Sader, JE
    Chon, JWM
    Mulvaney, P
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (10): : 3967 - 3969
  • [4] Difficulties in fitting the thermal response of atomic force microscope cantilevers for stiffness calibration
    Cole, D. G.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (12)
  • [5] METHOD FOR THE CALIBRATION OF ATOMIC-FORCE MICROSCOPE CANTILEVERS
    SADER, JE
    LARSON, I
    MULVANEY, P
    WHITE, LR
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (07): : 3789 - 3798
  • [6] Calibration of atomic force microscope cantilevers using piezolevers
    Aksu, Saltuk B.
    Turner, Joseph A.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (04):
  • [7] Frequency-dependent electrical and thermal response of heated atomic force microscope cantilevers
    Park, Keunhan
    Lee, Jungchul
    Zhang, Zhuomin M.
    King, William P.
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2007, 16 (02) : 213 - 222
  • [8] Characterization of heated atomic force microscope cantilevers in air and vacuum
    Lee, Jungchul
    Abel, Mark
    Wright, Tanya L.
    Sunden, Erik
    Marchenkov, Alexei
    Graham, Samuel
    King, William P.
    [J]. Advances in Electronic Packaging 2005, Pts A-C, 2005, : 1767 - 1772
  • [9] Calibration of the lateral spring constant of atomic force microscope cantilevers
    Song, Yunpeng
    Wu, Sen
    Xu, Linyan
    Fu, Xing
    [J]. AOPC 2015: MICRO/NANO OPTICAL MANUFACTURING TECHNOLOGIES; AND LASER PROCESSING AND RAPID PROTOTYPING TECHNIQUES, 2015, 9673
  • [10] A virtual instrument to standardise the calibration of atomic force microscope cantilevers
    Sader, John E.
    Borgani, Riccardo
    Gibson, Christopher T.
    Haviland, David B.
    Higgins, Michael J.
    Kilpatrick, Jason I.
    Lu, Jianing
    Mulvaney, Paul
    Shearer, Cameron J.
    Slattery, Ashley D.
    Thoren, Per-Anders
    Tran, Jim
    Zhang, Heyou
    Zhang, Hongrui
    Zheng, Tian
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (09):