Highly Sensitive TiO2/Au/Graphene Layer-Based Surface Plasmon Resonance Biosensor for Cancer Detection

被引:78
|
作者
Mostufa, Shahriar [1 ]
Akib, Tarik Bin Abdul [1 ]
Rana, Md Masud [1 ]
Islam, Md Rabiul [2 ]
机构
[1] Rajshahi Univ Engn & Technol, Dept Elect & Elect Engn, Rajshahi 6204, Bangladesh
[2] Univ Wollongong, Sch Elect Comp & Telecommfiunicat Engn, Wollongong, NSW 2522, Australia
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 08期
关键词
cancer detection; surface plasmon resonance biosensor; FEM; angular interrogation; biosensor; numerical approach; REFRACTIVE-INDEX SENSOR; LABEL-FREE; NUMERICAL APPROACH; SPR BIOSENSOR; BREAST-CANCER; GRAPHENE; CELLS; ENHANCEMENT; PERFORMANCE; DESIGN;
D O I
10.3390/bios12080603
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, a hybrid TiO2/Au/graphene layer-based surface plasmon resonance (SPR) sensor with improved sensitivity and capability for cancer detection is presented. The finite element method (FEM) was used for numerical analysis. The proposed SPR biosensor was structured based on the angular analysis of the attenuated total reflection (ATR) method for the detection of various types of cancer using the refractive index component. The resonance angle shifted owing to the increment of normal and cancerous cells' refractive index, which varied between 1.36 and 1.401 for six different types of normal and cancerous cells. According to numerical results, the obtained sensitivities for skin (basal), cervical (HeLa), adrenal gland (PC12), blood (Jurkat), and breast (MCF-7 and MDA-MB-231) cancer cells were 210 deg/RIU, 245.83 deg/RIU, 264.285 deg/RIU, 285.71 deg/RIU, 292.86 deg/RIU, and 278.57 deg/RIU, respectively. Furthermore, the detection accuracy (DA), figure of merits (EOM), and signal-to-noise ratio (SNR) were also obtained, with values of 0.263 deg(-1), 48.02 RIU-1, and 3.84, respectively. Additionally, the distribution of the electric field and the propagation of the magnetic field for resonant and non-resonant conditions of the proposed structure were illustrated. It was found that an enhanced field was exhibited on the surface of the plasmonic material for resonant conditions. We also measured the penetration depth of 180 nm using decayed electric field intensity. Furthermore, the impact of using a TiO2/Au/graphene layer was demonstrated. We further conducted analyses of the effects of the thickness of the gold layer and the effects of additional graphene layers on overall sensitivities for six different types of cancer. The proposed TiO2/Au/graphene layered structure exhibited the highest overall sensitivity in terms of detecting cancerous cells from healthy cells. Moreover, the proposed sensor was numerically analyzed for a wide range of biological solutions (refractive index 1.33-1.41), and the sensor linearity was calculated with a linear regression coefficient (R-2) of 0.9858. Finally, numerical results obtained in this manuscript exhibited high sensitivity in comparison with previously reported studies.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Ultra-sensitive surface plasmon resonance biosensor based on MoS2–graphene hybrid nanostructure with silver metal layer
    Hamid Vahed
    Cyrus Nadri
    Optical and Quantum Electronics, 2019, 51
  • [22] Ultra-sensitive surface plasmon resonance biosensor based on MoS2-graphene hybrid nanostructure with silver metal layer
    Vahed, Hamid
    Nadri, Cyrus
    OPTICAL AND QUANTUM ELECTRONICS, 2019, 51 (01)
  • [23] The fiber surface plasmon resonance sensor based on TiO2 /Au-NPs sensitization
    Du, Hua-Long
    Kari, Nuerguli
    Li, Ben
    Wang, Qi
    OPTICS AND LASER TECHNOLOGY, 2025, 181
  • [24] Highly Sensitive Terahertz Gas Sensor Based on Surface Plasmon Resonance With Graphene
    Xiang, Yuanjiang
    Zhu, Jiaqi
    Wu, Leiming
    You, Qi
    Ruan, Banxian
    Dai, Xiaoyu
    IEEE PHOTONICS JOURNAL, 2018, 10 (01):
  • [25] Design and Optimization of a Highly Sensitive Surface Plasmon Resonance Biosensor for Accurate Detection of Mycobacterium tuberculosis
    Mondal, Tanu Prava
    Mahmud, Russel Reza
    Rafi, Shah Ali
    Islam, M. Shariful
    Barua, Bobby
    IEEE SENSORS JOURNAL, 2025, 25 (06) : 9216 - 9223
  • [26] Streptavidin-enhanced surface plasmon resonance biosensor for highly sensitive and specific detection of microRNA
    Decai Zhang
    Yurong Yan
    Wei Cheng
    Wei Zhang
    Yahui Li
    Huangxian Ju
    Shijia Ding
    Microchimica Acta, 2013, 180 : 397 - 403
  • [27] Streptavidin-enhanced surface plasmon resonance biosensor for highly sensitive and specific detection of microRNA
    Zhang, Decai
    Yan, Yurong
    Cheng, Wei
    Zhang, Wei
    Li, Yahui
    Ju, Huangxian
    Ding, Shijia
    MICROCHIMICA ACTA, 2013, 180 (5-6) : 397 - 403
  • [28] Investigation of Highly Sensitive Surface Plasmon Resonance Biosensor Employing Black Phosphorous and Graphene Hybrid Structure
    Sahoo, Rasmita
    Nayak, Suryakanta
    Wu, Feng
    Gham, Poonam
    Daher, Malek G.
    Panda, Abinash
    PLASMONICS, 2023, 18 (04) : 1267 - 1275
  • [29] Investigation of Highly Sensitive Surface Plasmon Resonance Biosensor Employing Black Phosphorous and Graphene Hybrid Structure
    Rasmita Sahoo
    Suryakanta Nayak
    Feng Wu
    Poonam Gham
    Malek G. Daher
    Abinash Panda
    Plasmonics, 2023, 18 : 1267 - 1275
  • [30] Highly Sensitive Surface Plasmon Resonance Biosensor Using WSe2 and Silicon
    Nur, Jannati Nabiha
    Asrafy, Fairuj
    Shushama, Kamrun Nahar
    2018 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION & COMMUNICATION TECHNOLOGY (ICEEICT), 2018, : 246 - 250