A Compact Tunable Diode Laser Absorption Spectrometer to Monitor CO2 at 2.7 μm Wavelength in Hypersonic Flows

被引:18
|
作者
Vallon, Raphaeel [1 ]
Soutade, Jacques [1 ]
Verant, Jean-Luc [1 ]
Meyers, Jason [2 ]
Paris, Sebastien [2 ]
Mohamed, Ajmal [1 ]
机构
[1] Off Natl Etud & Rech Aerosp, French Aerosp Lab, FR-92322 Chatillon, France
[2] Von Karman Inst, B-1640 Rhode St Genese, Belgium
来源
SENSORS | 2010年 / 10卷 / 06期
关键词
gas sensor; tunable diode laser absorption spectroscopy; distributed feedback (DFB); laser velocimetry; CO2; monitoring; hypersonic flow; Mars atmosphere; TEMPERATURE; SPECTROSCOPY;
D O I
10.3390/s100606081
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Since the beginning of the Mars planet exploration, the characterization of carbon dioxide hypersonic flows to simulate a spaceship's Mars atmosphere entry conditions has been an important issue. We have developed a Tunable Diode Laser Absorption Spectrometer with a new room-temperature operating antimony-based distributed feedback laser (DFB) diode laser to characterize the velocity, the temperature and the density of such flows. This instrument has been tested during two measurement campaigns in a free piston tunnel cold hypersonic facility and in a high enthalpy arc jet wind tunnel. These tests also demonstrate the feasibility of mid-infrared fiber optics coupling of the spectrometer to a wind tunnel for integrated or local flow characterization with an optical probe placed in the flow.
引用
收藏
页码:6081 / 6091
页数:11
相关论文
共 50 条
  • [31] Fiber-coupled 2.7 μm laser absorption sensor for CO2 in harsh combustion environments
    Spearrin, R. M.
    Goldenstein, C. S.
    Jeffries, J. B.
    Hanson, R. K.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (05)
  • [32] Diode-pumped Er:CaF2 ceramic 2.7 μm tunable laser
    Sulc, Jan
    Nemec, Michal
    Svejkar, Richard
    Jelinkova, Helena
    Doroshenko, Maxim E.
    Fedorov, Pavel P.
    Osiko, Vyacheslav V.
    OPTICS LETTERS, 2013, 38 (17) : 3406 - 3409
  • [33] 2.3 μm diode laser absorption spectrometer for absolute CO measurements in gasification processes
    Physical Chemistry Institute, Heidelberg University, INF 253, Germany
    不详
    VDI Ber., 2008, 2047 (195-199):
  • [34] Compact pulsed CO2 laser with wavelength automatic tuning
    Pan Qi-kun
    Miao Fang-chen
    Si Hong-Li
    Shen Hui
    Gao Fei
    Yu De-Yang
    Zhang Kuo
    Zhang Ran-ran
    Zhao Chong-Xiao
    Chen Fei
    Guo Jin
    CHINESE OPTICS, 2022, 15 (05) : 1007 - 1012
  • [35] HETERODYNE FREQUENCY MEASUREMENTS WITH A TUNABLE DIODE LASER - CO2 LASER SPECTROMETER - SPECTROSCOPIC REFERENCE FREQUENCIES IN THE 9.5-MU-M BAND OF CARBONYL SULFIDE
    WELLS, JS
    PETERSEN, FR
    MAKI, AG
    APPLIED OPTICS, 1979, 18 (21): : 3567 - 3573
  • [36] Measurement of CO2 concentration at high-temperature based on tunable diode laser absorption spectroscopy
    Chen, Jiuying
    Li, Chuanrong
    Zhou, Mei
    Liu, Jianguo
    Kan, Ruifeng
    Xu, Zhenyu
    INFRARED PHYSICS & TECHNOLOGY, 2017, 80 : 131 - 137
  • [37] Study on CO2 Measurement Using Tunable Multi-Mode Diode Laser Absorption Spectroscopy
    Gao Guang-zhen
    Chen Bao-xue
    Hu Bo
    Long Xiu-hui
    Li Ai-ping
    Li Rong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (12) : 3269 - 3272
  • [38] Atmospheric CO2 measurements with a 2μm airborne laser absorption spectrometer employing coherent detection
    Spiers, Gary D.
    Menzies, Robert T.
    Jacob, Joseph
    Christensen, Lance E.
    Phillips, Mark W.
    Choi, Yonghoon
    Browell, Edward V.
    APPLIED OPTICS, 2011, 50 (14) : 2098 - 2111
  • [39] Measurement of water vapor line strengths in the 1.4-2.7 μm range by tunable diode laser absorption spectroscopy
    Pogany, Andrea
    Klein, Alexander
    Ebert, Volker
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2015, 165 : 108 - 122
  • [40] Diode-laser absorption measurements of CO2 near 2.0 μm at elevated temperatures
    Mihalcea, RM
    Baer, DS
    Hanson, RK
    APPLIED OPTICS, 1998, 37 (36) : 8341 - 8347