Venous port catheter implantation for chemotherapy: Our experience in pediatric cases Port-catheter experiences in pediatric cases

被引:0
|
作者
Aydin, Nevin [1 ]
Yilmaz, Gulseren [1 ]
Esen, Osman [2 ]
Esen, Hayrunisa Kahraman [3 ]
机构
[1] Univ Hlth Sci, Kanuni Sultan Suleyman Training & Res Hosp, Dept Anesthesiol & Reanimat, Istanbul, Turkey
[2] Istinye Univ, Vocat Sch Hlth, Dept Anesthesiol & Reanimat, Istanbul, Turkey
[3] Univ Hlth Sci, Fatih Sultan Mehmet Training & Res Hosp, Dept Pediat Surg, Istanbul, Turkey
来源
关键词
Child; Port catheters; Fluoroscopy; Vascular access; Ultrasound imaging; ACCESS DEVICES; ONCOLOGY; INFECTIONS; GUIDELINES;
D O I
10.4328/ACAM.20958
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: The use of central venous access devices and especially venous port catheters is increasing day by day due to frequent venous Interventions and long-term and painful treatment in chemotherapy treatment of cancer patients. In this study, we aimed to evaluate the applications of chemotherapy port-catheters in pediatric patients. Material and Methods: Between 2014 and 2017, 76 pediatric cancer patients who were inserted venous port catheters for chemotherapy treatment in our hospital were evaluated retrospectively. Demographic data, diagnoses, port implantation site, and complications observed during and after the procedure were examined. The ports were placed under general anesthesia. Fluoroscopy was used during port placement, but not ultrasound. Results: The mean age of the patients was 6.88 +/- 4.79 (1-16) years and consisted of 31 (40.8%) female and 45 (59.2%) male patients. A chemotherapy portcatheter was inserted through the right subclavian vein in 48 patients, the left subclavian vein in 27 patients, and the right internal jugular win in 1 patient Five French (n=46; 60.5%), 6Fr (n=18; 23.7%) and 7Fr (n-12; 15.8%) port catheters were used for the number of patients involved. Arterial puncture was seen in 17 patients. Infection developed in 12 patients who received antibiotic therapy. Resorbed pneumothorax developed in one (1.3%) patient. No malposition was observed during the procedure. Discussion: Despite some complications that may occur during chemotherapy port-catheter implantation in patients who will receive chemotherapy, it is a preferred method in terms of patient comfort. It is recommended to use imaging methods during and after the procedure to reduce complications.
引用
收藏
页码:419 / 422
页数:4
相关论文
共 50 条
  • [21] Retrograde embolization technique of the right gastric artery during the implantation of port-catheter system for hepatic arterial infusion chemotherapy
    Jungang Hu
    Guang Cao
    Liang Xu
    Kanglian Zheng
    Xu Zhu
    Renjie Yang
    Xiao Wang
    Xiaodong Wang
    Journal of Interventional Medicine, 2021, 4 (01) : 27 - 31
  • [22] Complications encountered with a transfemorally placed port-catheter system for hepatic artery chemotherapy infusion
    Kuroiwa, T
    Honda, H
    Yoshimitsu, K
    Irie, H
    Aibe, H
    Tajima, T
    Shinozaki, K
    Masuda, K
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (02) : 90 - 93
  • [23] Hepatic Arterial Infusion Chemotherapy by the Fixed-Catheter- Tip Method: Retrospective Comparison of Percutaneous Left Subclavian and Femoral Port-Catheter System Implantation
    Matsumoto, Tomohiro
    Yamagami, Takuji
    Yoshimatsu, Rika
    Morishita, Hiroyuki
    Kitamura, Noriko
    Sato, Osamu
    Hasebe, Terumitsu
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (01) : 211 - 215
  • [24] Assessment of the Antithrombogenicity of a Poly-2-Methoxyethylacrylate-Coated Central Venous Port-Catheter System
    Kariya, Shuji
    Nakatani, Miyuki
    Ono, Yasuyuki
    Maruyama, Takuji
    Ueno, Yutaka
    Komemushi, Atsushi
    Tanigawa, Noboru
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (05) : 775 - 780
  • [25] Brain infarction after percutaneous implantation of port-catheter system via the left subclavian artery
    Hirota, T
    Yamagami, T
    Tanaka, O
    Iida, S
    Kato, T
    Nakamura, T
    Ishihara, K
    Nishimura, T
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (898): : 799 - 804
  • [26] Assessment of the Antithrombogenicity of a Poly-2-Methoxyethylacrylate-Coated Central Venous Port-Catheter System
    Shuji Kariya
    Miyuki Nakatani
    Yasuyuki Ono
    Takuji Maruyama
    Yutaka Ueno
    Atsushi Komemushi
    Noboru Tanigawa
    CardioVascular and Interventional Radiology, 2020, 43 : 775 - 780
  • [27] Local Low-Dose Thrombolysis for Safe and Effective Treatment of Venous Port-Catheter Thrombosis
    Massmann, Alexander
    Jagoda, Philippe
    Kranzhoefer, Nicole
    Buecker, Arno
    ANNALS OF SURGICAL ONCOLOGY, 2015, 22 (05) : 1593 - 1597
  • [28] Local Low-Dose Thrombolysis for Safe and Effective Treatment of Venous Port-Catheter Thrombosis
    Alexander Massmann
    Philippe Jagoda
    Nicole Kranzhoefer
    Arno Buecker
    Annals of Surgical Oncology, 2015, 22 : 1593 - 1597
  • [29] Usefulness of peripherally inserted central catheter port system (PICC-PORT) implantation in the sitting position: a new technique for cases unsuitable for conventional implantation
    Narita, Akiko
    Takehara, Yumi
    Maruchi, Yuki
    Matsunaga, Nozomu
    Ikeda, Shuji
    Izumi, Yuichiro
    Ota, Toyohiro
    Suzuki, Kojiro
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (01) : 108 - 113
  • [30] Usefulness of peripherally inserted central catheter port system (PICC-PORT) implantation in the sitting position: a new technique for cases unsuitable for conventional implantation
    Akiko Narita
    Yumi Takehara
    Yuki Maruchi
    Nozomu Matsunaga
    Shuji Ikeda
    Yuichiro Izumi
    Toyohiro Ota
    Kojiro Suzuki
    Japanese Journal of Radiology, 2023, 41 : 108 - 113