Real-Time Detection of Aerosol Metals Using Online Extractive Electrospray Ionization Mass Spectrometry

被引:25
|
作者
Giannoukos, Stamatios [1 ,2 ]
Lee, Chuan Ping [1 ]
Tarik, Mohamed [2 ]
Ludwig, Christian [2 ,3 ]
Biollaz, Serge [2 ]
Lamkaddam, Houssni [1 ]
Baltensperger, Urs [1 ]
Prevot, Andre Stephan Henry [1 ]
Slowik, Jay [1 ]
机构
[1] Paul Scherrer Inst, Lab Atmospher Chem, CH-5232 Villigen, Switzerland
[2] Paul Scherrer Inst, Bioenergy & Catalysis Lab, CH-5232 Villigen, Switzerland
[3] Ecole Polytech Fed Lausanne, Engn ENAC, CH-1015 Lausanne, Switzerland
基金
欧盟地平线“2020”; 瑞士国家科学基金会;
关键词
D O I
10.1021/acs.analchem.9b04480
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Metal emissions are of major environmental and practical concern because of their highly toxic effects on human health and ecosystems. Current technologies available in the market for their detection are typically limited by a time resolution of 1 h or longer (e.g., via semicontinuous X-ray fluorescence measurements) or are nonquantitative (e.g., laser ablation mass spectrometry). In this work, we report the development of a novel technique for the real-time detection and monitoring of metal particles in situ using an extractive electrospray ionization (EESI) source coupled to a high -resolution time -of-flight mass spectrometer (TOF-MS). The experiments were conducted in negative ionization mode using disodium ethylenediamine tetraacetic acid (EDTA) dihydrate to chelate with metals and form stable metal complexes. Results for water-soluble metal compounds were obtained. The following representative metal ions were examined: Pb, Cd, Zn, Ce (III), Ba, Ni, Fe(II), Fe(III), Cu(II), Cr, Mo, Co(II), Mg, Nd, Li, Ti, Ca, Cs, Ag, Tm, Er(III), La(III), Yb(III), Eu(III), Pr(III), Gd(III), Lu(III), Dy(III), Tb(III), Ho, and Ru(III). The results showed a very good linear mass response (R-2 = 0.9983), low ng/m(3) limits of detection (LoD), and a fast response time (1 s). The stability and repeatability of the developed EESI-TOF-MS were tested under complex dynamic and periodic experimental conditions, and negligible matrix effects were measured for internally and externally mixed metal particles. Benchmark testing against inductively coupled plasma-mass spectrometry (ICP-MS) was also performed, highlighting the online measurement capabilities of aerosol metals with a LoD lower than those of ICP-MS. Proof-of-concept ambient measurements were performed in New Delhi, India, and very promising results were obtained, allowing further exploitation elsewhere.
引用
收藏
页码:1316 / 1325
页数:10
相关论文
共 50 条
  • [21] Direct detection of native proteins in biological matrices using extractive electrospray ionization mass spectrometry
    Hu, Bin
    Yang, Shuiping
    Li, Ming
    Gu, Haiwei
    Chen, Huanwen
    ANALYST, 2011, 136 (18) : 3599 - 3601
  • [22] Extractive electrospray ionization mass spectrometry of ionic liquids
    Zhou, Yafei
    Chingin, Konstantin
    Li, Cao
    Yang, Shuiping
    Xiao, Saijin
    Zhu, Liang
    Chen, Huanwen
    ANALYTICAL METHODS, 2014, 6 (18) : 7190 - 7194
  • [23] Direct Detection of Acetonitrile in Human Breath by Extractive Electrospray Ionization Mass Spectrometry
    Zhang Yan
    Pan Su-Su
    Zhu Zhi-Qiang
    Zhang Xing-Lei
    Xu Gao-Si
    Wei Yi-Ping
    Chen Huan-Wen
    Ding Jian-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (08) : 1220 - 1225
  • [24] Detection of a Novel Metabolite of Urea in Soil by Extractive Electrospray Ionization Mass Spectrometry
    Pan Su-Su
    Zhao Na
    Ouyang Yong-Zhong
    Huang Ke-Ke
    Ding Jian-Hua
    Chen Huan-Wen
    Yuan Long
    Wang Xing-Xiang
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2013, 34 (06): : 1379 - 1384
  • [25] DETECTION OF HEMOGLOBIN CAPTURED ON GRAPHENE BY INTERNAL EXTRACTIVE ELECTROSPRAY IONIZATION MASS SPECTROMETRY
    Song, L. L.
    Wang, X. Z.
    Chingin, K.
    Li, Y.
    Hua, R.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2017, 121 : 54 - 54
  • [26] Real-Time Detection of m-Toluidine Electrooxidation Using Electrochemistry-Micro Electrospray Ionization-Mass Spectrometry
    Yu K.
    Zhang M.-W.
    Hong Z.-Y.
    Zhang H.
    Jiang J.
    Journal of Chinese Mass Spectrometry Society, 2021, 42 (04): : 462 - 469
  • [27] Real-time monitoring of the reaction between aniline and acetonylacetone using extractive electorspray ionization tandem mass spectrometry
    Xinglei Zhang
    Miaorong Pei
    Debo Wu
    Shuiping Yang
    Zhanggao Le
    Scientific Reports, 9
  • [28] Real-time monitoring of the reaction between aniline and acetonylacetone using extractive electorspray ionization tandem mass spectrometry
    Zhang, Xinglei
    Pei, Miaorong
    Wu, Debo
    Yang, Shuiping
    Le, Zhanggao
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [29] Detection of trace levels of lead in aqueous liquids using extractive electrospray ionization tandem mass spectrometry
    Liu, Chunxiao
    Zhang, Xinglei
    Xiao, Saijin
    Jia, Bin
    Cui, Shasha
    Shi, Jianbo
    Xu, Ning
    Xie, Xi
    Gu, Haiwei
    Chen, Huanwen
    TALANTA, 2012, 98 : 79 - 85
  • [30] Extractive Electrospray Ionization Mass Spectrometry Enhanced Sensitivity Using an Ion Funnel
    Meier, Lukas
    Berchtold, Christian
    Schmid, Stefan
    Zenobi, Renato
    ANALYTICAL CHEMISTRY, 2012, 84 (04) : 2076 - 2080