Effects of acetabular abduction on cup wear rates in total hip arthroplasty

被引:113
|
作者
Del Schutte, H [1 ]
Lipman, AJ [1 ]
Bannar, SM [1 ]
Livermore, JT [1 ]
Ilstrup, D [1 ]
Morrey, BF [1 ]
机构
[1] Med Univ S Carolina, Dept Orthopaed Surg, Charleston, SC 29425 USA
来源
JOURNAL OF ARTHROPLASTY | 1998年 / 13卷 / 06期
关键词
hip arthroplasty; polyethylene wear rates; acetabular abduction;
D O I
10.1016/S0883-5403(98)80003-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to determine the effect of acetabular abduction on the polyethylene wear rates of the acetabular component. The hypothesis of this study is that acetabular placement, in particular abduction, effects contact forces and therefore polyethylene wear. A total of 364 total hip arthroplasties that were performed between 1974 and 1976 were included in this study. The cemented all-polyethylene acetabular components were the same for each case and came from a single supplier. The polyethylene wear rates were calculated by measuring the shortest radius from the center of the prosthetic femoral head to a point on the outer surface of the acetabular cup. An immediate postoperative radiograph was compared with a follow-up radiograph at least 9.5 years later. A standardized radiograph was used to prevent differences due to magnification. The abduction or inclination of the acetabular cups was measured in all of the patients. The amount of acetabular cup abduction was measured relative to the ischial tuberosity line. The mean abduction was 44.1 degrees with a standard deviation of 9.2 degrees and a median of 44 degrees. The range of abduction was from 0 degrees to 85 degrees. This analysis failed to show a correlation between the amount of acetabular abduction and polyethylene wear rates (Pearson's correlation coefficient = 0.0679; P = .20). With a sample size of 364, there is over a 95% change (statistical power) of detecting an underlying true correlation between wear and abduction that is greater than or equal to 0.20. We were unable to demonstrate a difference in wear that would correlate with the differing degrees of abduction of the acetabular socket. We felt that the radiographic measurements of wear were quite accurate. This method of determining acetabular abduction has also been documented and supported in previous literature and has allowed us to accurately determine acetabular abduction. The results of our study demonstrate that within the normal ranges described by our study, polyethylene wear did not significantly increase with increased abduction of the acetabular component.
引用
收藏
页码:621 / 626
页数:6
相关论文
共 50 条
  • [31] Reliability of the transverse acetabular ligament as a landmark for functional cup anteversion in total hip arthroplasty
    Jassim, Shivan S.
    Bhatia, Tejasvi
    McMahon, Jack R. D.
    Pierrepont, Jim W.
    McMahon, Stephen J.
    HIP INTERNATIONAL, 2024, 34 (05) : 608 - 613
  • [32] Resolving inconsistencies in defining the target orientation for the acetabular cup angles in total hip arthroplasty
    Yoon, Yong-San
    Hodgson, Antony J.
    Tonetti, Jerome
    Masri, Bassam A.
    Duncan, Clive P.
    CLINICAL BIOMECHANICS, 2008, 23 (03) : 253 - 259
  • [33] Acute total hip arthroplasty in acetabular fractures using modern porous metal cup
    Malhotra, Rajesh
    Gautam, Deepak
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [34] Acetabular cup orientation optimization following total hip arthroplasty using predictive simulation
    Danaei, Behzad
    Mcphee, John
    MULTIBODY SYSTEM DYNAMICS, 2025,
  • [35] A novel mechanical inclinometer device to measure acetabular cup inclination in total hip arthroplasty
    van Duren B.H.
    Al Ashqar M.
    Lamb J.N.
    Pandit H.G.
    Brew C.
    Journal of Medical Engineering and Technology, 2020, 44 (08): : 481 - 488
  • [36] Measurement of acetabular cup orientation in total hip arthroplasty using a volume registration technique
    Yamanashi, W
    Sugano, N
    Watanabe, Y
    Sato, Y
    Nishii, T
    Miki, H
    Yoshikawa, H
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1298 - 1298
  • [37] Titanium debris in acetabular cup failures after total hip arthroplasty: histopathological perspectives
    Fokter, S. K.
    Ledinek, Z.
    Punzon-Quijorna, E.
    Novak, I.
    Molicnik, A.
    VIRCHOWS ARCHIV, 2024, 485 : S366 - S367
  • [38] ACETABULAR CUP ALIGNMENT IN TOTAL HIP RECONSTRUCTION
    EVARTS, CM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1974, (103) : 22 - 23
  • [39] Letter to the Editor Response: Failure of Cup Screw Interface in the Trident II Acetabular Cup in Total Hip Arthroplasty
    Ulrich, Paul A.
    Zondervan, Robert L.
    Cochran, Jason M.
    ARTHROPLASTY TODAY, 2024, 27
  • [40] Cup positioning in total hip arthroplasty
    Scheerlinck, Thierry
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (03): : 336 - 347