Current status of urban wastewater treatment plants in China

被引:467
|
作者
Zhang, Q. H. [1 ,2 ]
Yang, W. N. [2 ]
Ngo, H. H. [3 ]
Guo, W. S. [3 ]
Jin, P. K. [2 ]
Dzakpasu, Mawuli [2 ]
Yang, S. J. [1 ]
Wang, Q. [1 ]
Wang, X. C. [1 ]
Ao, D. [1 ]
机构
[1] Xian Univ Architecture & Technol, Key Lab Northwest Water Resource Environm & Ecol, Minist Educ, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Peoples R China
[3] Univ Technol Sydney, Ctr Technol Water & Wastewater, Sch Civil & Environm Engn, POB 123, Sydney, NSW 2007, Australia
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
Wastewater treatment plants (WWTPs); Regional sewage treatment; Discharge standard and upgrading; Sludge disposal; Energy consumption; Wastewater reclamation and reuse; SEWAGE-SLUDGE; HEAVY-METAL; SPECIATION;
D O I
10.1016/j.envint.2016.03.024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study reported and analyzed the current state of wastewater treatment plants (WWTPs) in urban China from the perspective of treatment technologies, pollutant removals, operating load and effluent discharge standards. By the end of 2013, 3508 WWTPs have been built in 31 provinces and cities in China with a total treatment capacity of 1.48 x 10(8) m(3)/d. The uneven population distribution between China's east and west regions has resulted in notably different economic development outcomes. The technologies mostly used in WWTPs are MO and oxidation ditch, which account for over 50% of the existing WWTPs. According to statistics, the efficiencies of COD and NH3-N removal are good in 656 WWTPs in 70 cities. The overall average COD removal is over 88% with few regional differences. The average removal efficiency of NH3-N is up to 80%. Large differences exist between the operating loads applied in different WWTPs. The average operating loading rate is approximately 83%, and 52% of WWTPs operate at loadings of <80%, treating up to 40% of the wastewater generated. The implementation of discharge standards has been low. Approximately 28% of WWTPs that achieved the Grade I-A Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002) were constructed after 2010. The sludge treatment and recycling rates are only 25%, and approximately 15% of wastewater is inefficiently treated. Approximately 60% of WWTPs have capacities of 1 x 10(4) m(3)/d-5 x 10(4) m(3)/d. Relatively high energy consumption is required for small-scale processing, and the utilization rate of recycled wastewater is low. The challenges of WWTPs are discussed with the aim of developing rational criteria and appropriate technologies for water recycling. Suggestions regarding potential technical and administrative measures are provided. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:11 / 22
页数:12
相关论文
共 50 条
  • [41] Occurrence, distribution and risk assessment of phthalate esters in 51 urban wastewater treatment plants in Shaanxi Province, China
    Wang, Xiaoyu
    Hu, En
    Yang, Chenghua
    Li, Ming
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (03):
  • [42] Current Status and Future Strategies for Development of Transgenic Plants in China
    De-Ping Wang (China National Centre for Biotechnology Development
    JournalofIntegrativePlantBiology, 2007, (09) : 1281 - 1283
  • [43] Current status and future strategies for development of Transgenic plants in China
    Wang, De-Ping
    JOURNAL OF INTEGRATIVE PLANT BIOLOGY, 2007, 49 (09) : 1281 - 1283
  • [44] Energy intensity of wastewater treatment plants and influencing factors in China
    Niu, Kunyu
    Wu, Jian
    Qi, Lu
    Niu, Qianxin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 670 : 961 - 970
  • [45] A Dataset of Distribution and Characterization of Underground Wastewater Treatment Plants in China
    Zhou, Shuyan
    Gong, Hui
    Chen, Xiang
    Wang, Xiankai
    Wang, Hang
    Zhang, Yanyan
    Zhu, Danyang
    Cao, Xiaoxin
    Li, Sen
    Dai, Xiaohu
    SCIENTIFIC DATA, 2024, 11 (01)
  • [46] Occurrence and fate of androgens in municipal wastewater treatment plants in China
    Yu, Qingmiao
    Geng, Jinju
    Ren, Hongqiang
    CHEMOSPHERE, 2019, 237
  • [47] Current Status of Rectal Cancer Treatment in China
    Gu, Jin
    Chen, Nan
    E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE, 2015, 14 (02): : 45 - 50
  • [48] The Current Status of Antioxidants in the Treatment of Vitiligo in China
    Zhou, Ying
    Khan, Manal
    Jiang, Ling
    Fu, Chuhan
    Dong, Yumeng
    Luo, Liping
    Guo, Haoran
    Gao, Lijuan
    Lei, Xinxin
    Zhang, Li
    Yu, Xing
    Lei, Li
    Huang, Jinhua
    Chen, Jing
    Zeng, Qinghai
    OXIDATIVE MEDICINE AND CELLULAR LONGEVITY, 2022, 2022
  • [49] Current status of rectal cancer treatment in China
    Gu, J.
    Chen, N.
    COLORECTAL DISEASE, 2013, 15 (11) : 1345 - 1350
  • [50] Assessment of energy consumption of municipal wastewater treatment plants in China
    He, Yan
    Zhu, Yishuang
    Chen, Jinghan
    Huang, Minsheng
    Wang, Pan
    Wang, Guohua
    Zou, Weiguo
    Zhou, Gongming
    JOURNAL OF CLEANER PRODUCTION, 2019, 228 : 399 - 404