The effects of non-vacuum packaging systems on drip loss from chilled beef

被引:37
|
作者
Payne, SR [1 ]
Durham, CJ [1 ]
Scott, SM [1 ]
Devine, CE [1 ]
机构
[1] Meat Ind Res Inst New Zealand Inc, Hamilton, New Zealand
关键词
D O I
10.1016/S0309-1740(97)00135-6
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
This study investigated drip loss in chilled beef (hot-boned m. longissimus lumborum (LL)) under conventional packaging systems, in which a vacuum is applied, and non-vacuum packaging systems. The use of vacuum during the packaging process (vacuum packaging, CO2 atmosphere packaging) was associated with increased drip. Drip was lower in heat-shrunk vacuum packaging than in non-shrunk vacuum packaging. A slow vacuum onset had no effect on drip formation, or may have increased it. The extent of pressure reduction (vacuum; range 0-1 atm) did not significantly affect drip formation, although the standard vacuum pressure (0 atm) tended to cause more drip loss than higher pressures. The three non-vacuum anaerobic packaging systems tested were:pushed with carbon dioxide without the pressure being reduced below atmospheric (Flush), or the same system with no CO2 flush but a proprietary oxygen absorber added (Scavenger), or a combination of both (Flush/Scavenger). Storage was at -1.5 degrees C for up to 20 weeks. The Flush and Flush/Scavenger systems had considerably lower drip loss than the CAP standard system (64%, 6.5%, and 9.1% respectively), the Scavenger system had the lowest drip loss (5.2%). Drip losses generally increased with storage period, irrespective of packaging system. All non-vacuum packaging systems except the Flush system had very low oxygen levels (< 0.1% v/v). The Flush system had considerably higher levels of oxygen (0.9%) with associated browning of meat samples. All packaging systems gave a hygienic shelf-life of at least 16 weeks. At 16 weeks, microbial numbers were highest (5 x 10(6)) in the Scavenger system. The meat from all packaging systems was acceptable to taste panels even after 16 weeks of storage at -1.5 degrees C.. There were no significant differences between any of the packaging systems for any of the sensory attributes tested. The packaging systems with the best all round performance were the Flush/Scavenger and the Scavenger systems, depending on the storage-life required. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:277 / 287
页数:11
相关论文
共 50 条
  • [1] Performance of an Electrostatic Actuated Micromirror in a Vacuum and Non-Vacuum Packaging
    Khan, I.
    Chong, J.
    Ben Mrad, R.
    He, S.
    Schertzer, M. J.
    [J]. 38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 3987 - 3990
  • [2] Structural-Acoustic Coupling Effects on the Non-Vacuum Packaging Vibratory Cylinder Gyroscope
    Xi, Xiang
    Wu, Xuezhong
    Wu, Yulie
    Zhang, Yongmeng
    Tao, Yi
    Zheng, Yu
    Xiao, Dingbang
    [J]. SENSORS, 2013, 13 (12) : 17176 - 17192
  • [3] VACUUM PACKAGED BEEF FROM 2 KINDS OF PACKAGING SYSTEMS
    BOWLING, RA
    CARPENTER, ZL
    SMITH, GC
    [J]. JOURNAL OF ANIMAL SCIENCE, 1975, 41 (01) : 286 - 286
  • [4] FREEZING RATE EFFECTS ON THE DRIP LOSS OF FROZEN BEEF
    ANON, MC
    CALVELO, A
    [J]. MEAT SCIENCE, 1980, 4 (01) : 1 - 14
  • [5] VACUUM PACKAGING SYSTEMS FOR SUB-PRIMAL BEEF CUTS
    BOWLING, RA
    CARPENTER, ZL
    SMITH, GC
    HOKE, KE
    [J]. JOURNAL OF ANIMAL SCIENCE, 1977, 45 (06) : 1280 - 1288
  • [6] The effect of storage temperature on drip loss from fresh beef
    den Hertog-Meischke, MJA
    Smulders, FJM
    van Logtestijn, JG
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1998, 78 (04) : 522 - 526
  • [7] Molecular characterization of lactic acid bacteria isolated from beef and stored using vacuum-packaging and advanced vacuum skin packaging systems
    Samuel, A.
    Miranda, J. M.
    Guarddon, M.
    Nebot, C. G.
    Calo-Mata, M. P.
    Cepeda, A.
    Franco, C. M.
    [J]. CYTA-JOURNAL OF FOOD, 2011, 9 (04) : 335 - 341
  • [8] THE EFFECT OF FREEZING RATE ON THE DRIP LOSS FROM FROZEN BEEF
    NAIR, C
    JAMES, SJ
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1983, 34 (09) : 1020 - 1020
  • [9] The Application of a Compound Natural Preservative Solution to Chilled Beef and Mutton Under Vacuum Packaging During Refrigerated Storage
    Hao, Jiaomin
    Yang, Wenping
    Yang, Hua
    Ma, Lizhen
    [J]. FOOD SCIENCE AND TECHNOLOGY RESEARCH, 2013, 19 (04) : 591 - 599
  • [10] COMPARISON OF VACUUM PACKAGING SYSTEMS AND FILMS ON PHYSICAL CHARACTERISTICS OF BEEF CUTS
    SEIDEMAN, SC
    CARPENTER, ZL
    SMITH, GC
    VANDERZANT, C
    HOKE, KE
    [J]. JOURNAL OF MILK AND FOOD TECHNOLOGY, 1976, 39 (11): : 740 - 744