Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea

被引:30
|
作者
BaHammam, Ahmed [1 ]
Sharif, Munir [1 ]
Gacuan, Divinagracia E. [1 ]
George, Smitha [1 ]
机构
[1] King Saud Univ, Univ Sleep Disorders Ctr, Coll Med, Riyadh 11324, Saudi Arabia
来源
MEDICAL SCIENCE MONITOR | 2011年 / 17卷 / 02期
关键词
sleep-disordered breathing; sleep apnea; ApneaLink; polysomnography; type 4 sleep study; portable monitoring;
D O I
10.12659/MSM.881379
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: ApneaLink (TM) (AL) is a single-channel type-4 device that measures airflow. A limited number of studies have assessed AL's usefulness in diagnosing obstructive sleep apnea (OSA) using automated scoring alone. This study was conducted to assess the sensitivity and specificity of AL in a selected group of people with clinical suspicion of OSA, using both automatic and manual scoring and comparing the results with those obtained for polysomnography (PSG). Material/Methods: Simultaneous overnight recordings of in-laboratory PSG and AL were performed for 95 patients (mean age 46.3 +/- 12.6 yr) with a high clinical suspicion of OSA. PSG was scored manually according to the American Academy of Sleep Medicine (AASM) guidelines. AL data were analyzed automatically using a manufacturer-provided computerized algorithm. Manual scoring of the AL flow signal followed the AASM guidelines for reduction in flow. Results: The mean apnea hypopneas index (AHI) for PSG was 34.1 +/- 32.4/hr. The AL Auto-AHI was 20.1 +/- 25.2/h, and the AL Manual-AHI was 39.5 +/- 30.4/h. The Pearson correlation coefficients were r = 0.883 between PSG-AHI and AL Auto-AHI, and r = 0.966 between PSG-AHI and AL Manual-AHI. At AHIs of 5, 10, 15, and 30, the AL Auto sensitivity/specificity was 0.79/0.68, 0.70/0.89, 0.64/0.94 and 0.63/0.98, and the AL Manual sensitivity/specificity was 1.00/0.43, 1.00/0.56, 0.98/0.58 and 1.00/0.80. Conclusions: Combining auto and manual scoring of data (automatic scoring followed by manual scoring) recorded by single-channel ApneaLink (TM) provides good diagnostic agreement with conventional PSG recordings.
引用
收藏
页码:MT13 / MT19
页数:7
相关论文
共 50 条
  • [11] Accuracy of clinical evaluation in pediatric obstructive sleep apnea
    Wang, RC
    Elkins, TP
    Keech, D
    Wauquier, A
    Hubbard, D
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1998, 118 (01) : 69 - 73
  • [12] Automatic pressure titration with APAP is as effective as manual titration with CPAP in patients with obstructive sleep apnea
    Fietze, Ingo
    Glos, Martin
    Moebus, Isabel
    Witt, Christian
    Penzel, Thomas
    Baumann, Gert
    RESPIRATION, 2007, 74 (03) : 279 - 286
  • [13] Sleep measurement accuracy of smartwatch in patients with obstructive sleep apnea
    Park, Kunwoo
    Shin, Wonchul
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2023, 455
  • [14] Indication of CPAP without a sleep study in patients with high pretest probability of obstructive sleep apnea
    Alberto Nigro, Carlos
    Borsini, Eduardo
    Dibur, Eduardo
    Larrateguy, Luis
    Cazaux, Alexis
    Elias, Carlos
    de la Vega, Marcelino
    Berrozpe, Cecilia
    Maggi, Silvana
    Grandval, Sofia
    Cambursano, Hugo
    Visentini, Daniela
    Blanco, Magali
    Ernst, Glenda
    Bledel, Ignacio
    Nogueira, Facundo
    SLEEP AND BREATHING, 2020, 24 (03) : 1043 - 1050
  • [15] Indication of CPAP without a sleep study in patients with high pretest probability of obstructive sleep apnea
    Carlos Alberto Nigro
    Eduardo Borsini
    Eduardo Dibur
    Luis Larrateguy
    Alexis Cazaux
    Carlos Elias
    Marcelino de la Vega
    Cecilia Berrozpe
    Silvana Maggi
    Sofía Grandval
    Hugo Cambursano
    Daniela Visentini
    Magali Blanco
    Glenda Ernst
    Ignacio Bledel
    Facundo Nogueira
    Sleep and Breathing, 2020, 24 : 1043 - 1050
  • [16] Treatment of obstructive sleep apnea syndrome by monitoring patients airflow signals
    Kermit, M
    Eide, ÅJ
    Lindblad, T
    Waldemark, K
    PATTERN RECOGNITION LETTERS, 2000, 21 (03) : 277 - 281
  • [17] Agreement between manual and automatic analyses of home sleep examinations in pediatric obstructive sleep apnea
    Orntoft, Marie
    Andersen, Ida G.
    Homoe, Preben
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2019, 8 (08) : 623 - 631
  • [18] Evaluation of a single channel portable monitor for the diagnosis of obstructive sleep apnea: An interim analysis
    Fassero, M.
    Gupta, N.
    Atwood, C.
    Givelber, R.
    Drumheller, O.
    Peterson, J.
    Rogers, S.
    Strollo, P.
    SLEEP, 2007, 30 : A202 - A202
  • [19] Evaluation of MIh Scoring System in Diagnosis of Obstructive Sleep Apnea Syndrome
    Xu, Qinxing
    Du, Junwei
    Ling, Xiaobo
    Lu, Yangfei
    MEDICAL SCIENCE MONITOR, 2017, 23 : 4715 - 4722
  • [20] Differences between manual and automatic analysis in determining the severity of obstructive sleep apnea using home sleep apnea testing
    Labarca, Gonzalo
    Dreyse, Jorge
    Salas, Constanza
    Contreras, Andrea
    Nazar, Gonzalo
    Gaete, Maria I.
    Jorquera, Jorge
    SLEEP MEDICINE, 2018, 47 : 66 - 71