Background: ApneaLink (TM) (AL) is a single-channel type-4 device that measures airflow. A limited number of studies have assessed AL's usefulness in diagnosing obstructive sleep apnea (OSA) using automated scoring alone. This study was conducted to assess the sensitivity and specificity of AL in a selected group of people with clinical suspicion of OSA, using both automatic and manual scoring and comparing the results with those obtained for polysomnography (PSG). Material/Methods: Simultaneous overnight recordings of in-laboratory PSG and AL were performed for 95 patients (mean age 46.3 +/- 12.6 yr) with a high clinical suspicion of OSA. PSG was scored manually according to the American Academy of Sleep Medicine (AASM) guidelines. AL data were analyzed automatically using a manufacturer-provided computerized algorithm. Manual scoring of the AL flow signal followed the AASM guidelines for reduction in flow. Results: The mean apnea hypopneas index (AHI) for PSG was 34.1 +/- 32.4/hr. The AL Auto-AHI was 20.1 +/- 25.2/h, and the AL Manual-AHI was 39.5 +/- 30.4/h. The Pearson correlation coefficients were r = 0.883 between PSG-AHI and AL Auto-AHI, and r = 0.966 between PSG-AHI and AL Manual-AHI. At AHIs of 5, 10, 15, and 30, the AL Auto sensitivity/specificity was 0.79/0.68, 0.70/0.89, 0.64/0.94 and 0.63/0.98, and the AL Manual sensitivity/specificity was 1.00/0.43, 1.00/0.56, 0.98/0.58 and 1.00/0.80. Conclusions: Combining auto and manual scoring of data (automatic scoring followed by manual scoring) recorded by single-channel ApneaLink (TM) provides good diagnostic agreement with conventional PSG recordings.
引用
收藏
页码:MT13 / MT19
页数:7
相关论文
共 50 条
  • [1] EVALUATION OF A SINGLE CHANNEL AIRFLOW DEVICE FOR DIAGNOSIS OF OBSTRUCTIVE SLEEP APNEA SYNDROME IN OBESE PEDIATRIC PATIENTS
    Lesser, D. J.
    Pian, M. S.
    Farrell, M. J.
    DeWitte, J.
    Haddad, G. G.
    SLEEP, 2011, 34 : A272 - A272
  • [2] Automatic Sleep Staging in Patients With Obstructive Sleep Apnea Using Single-Channel Frontal EEG
    Lee, Pei-Lin
    Huang, Yi-Hao
    Lin, Po-Chen
    Chiao, Yu-An
    Hou, Jen-Wen
    Liu, Hsiang-Wen
    Huang, Ya-Ling
    Liu, Yu-Ting
    Chiueh, Tzi-Dar
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2019, 15 (10): : 1411 - 1420
  • [3] AASM Scoring Manual 3: a step forward for advancing sleep care for patients with obstructive sleep apnea
    Malhotra, Raman K.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2024, 20 (05): : 835 - 836
  • [4] Assessment of airflow limitation in patients with obstructive sleep apnea
    El-Sorougi, Waleed Mohamed Kamal Eldin
    Ali, Mohamed Alaa Abdelhamid
    Abdalrazik, Fatmaalzahraa Saad
    EGYPTIAN JOURNAL OF BRONCHOLOGY, 2024, 18 (01)
  • [5] Does Scoring Of Autonomic Hypopneas Improve The Diagnostic Accuracy Of Type 3 Home Sleep Recordings In Patients With High Pre-Test Probability Of Obstructive Sleep Apnea?
    Cascon, J. A.
    Pamidi, S.
    Lachapelle, P.
    Kimoff, R. J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [6] Accuracy of clinical scoring tools for the diagnosis of pediatric obstructive sleep apnea
    Patel, Anant P.
    Meghji, Sheneen
    Phillips, John S.
    LARYNGOSCOPE, 2020, 130 (04): : 1034 - 1043
  • [7] Comparison between a Single-Channel Nasal Airflow Device and Oximetry for the Diagnosis of Obstructive Sleep Apnea
    Rofail, Lydia Makarie
    Wong, Keith K. H.
    Unger, Gunnar
    Marks, Guy B.
    Grunstein, Ronald R.
    SLEEP, 2010, 33 (08) : 1106 - 1114
  • [8] Spectral Analysis of Single-Channel Airflow and Oxygen Saturation Recordings in Obstructive Sleep Apnea Detection
    Alvarez, Daniel
    Gutierrez, G. C.
    Victor Marcos, J.
    del Campo, Felix
    Hornero, Roberto
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 847 - 850
  • [9] Unreliability of automatic scoring of MESAM 4 in assessing patients with complicated obstructive sleep apnea syndrome
    Cirignotta, F
    Mondini, S
    Gerardi, R
    Mostacci, B
    Sancisi, E
    CHEST, 2001, 119 (05) : 1387 - 1392
  • [10] Evaluation of a Single-Channel Portable Monitor for the Diagnosis of Obstructive Sleep Apnea
    Oktay, Burcu
    Rice, Thomas B.
    Atwood, Charles W., Jr.
    Passero, Michael, Jr.
    Gupta, Neeraj
    Givelber, Rachel
    Drumheller, Oliver J.
    Houck, Patricia
    Gordon, Nancy
    Strollo, Patrick J., Jr.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2011, 7 (04): : 384 - 390