摘要
Electrocardiogram (ECG) signals have been used to monitor and diagnose signs of cardiovascular disease and abnormal signals about the human body. ECG signals are typically characterized by the PR, QRS, QT interval, ST-segment, and heart rate (HR) parameters. ECG devices are widely used for many applications, especially for the elderly. However, ECG signals are often affected by noises from the environment. There are mainly two types of noises that affect the ECG signals: low frequencies from muscle activity and 50/60 Hz from the electrical grid. Removing these noises is important for improving the quality of the ECG signal. A clear ECG signal makes it easy to diagnose cardiovascular problems. ECG signals with high sampling frequency are more accurate. However, the noises in the signal will be more obvious and it will be difficult to remove these noises with filters. We analyzed the symmetrical correlation between the sampling frequency of the signal and the parameters of the signal such as signal to noise ratio (SNR) and signal amplitude. This study will compare characterization of ECG signals performed at different sampling frequencies before and after applying infinite impulse response (IIR) and symmetric finite impulse response (FIR) filters. Therefore, it is critical that the sampling frequency is consistent at the same frequency of the ECG signal for accurate diagnosis. Furthermore, the approach can be also important for the device to help reduce the device's computing power and hardware resources. Our results were tested with the MIT/ BIH database at 360 Hz sampling frequency with 11-bit resolution. We also experimented with the device operating in real-time with a sampling frequency from 100 Hz to 2133 Hz and a 24-bit resolution. The test results show the advantages of the symmetric FIR filter over IIR when applied to the filtering of ECG signals. The study's conclusions can be applied to real-world devices to improve the quality of ECG signals.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] SAMPLING AND REAL-TIME METHODS IN ELECTROOPTIC PROBING SYSTEM
    TAKAHASHI, H
    AOSHIMA, SI
    TSUCHIYA, Y
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (05) : 965 - 971
  • [22] Real-time condition monitoring by significant and natural frequencies analysis of vibration signal with wavelet filter and autocorrelation enhancement
    Luo, GY
    Osypiw, D
    Irle, M
    JOURNAL OF SOUND AND VIBRATION, 2000, 236 (03) : 413 - 430
  • [23] COMPARISON OF METHODS FOR DETERMINING CROWN-RUMP MEASUREMENT BY REAL-TIME ULTRASOUND
    NELSON, LH
    JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (02) : 67 - 70
  • [24] A New Signal Processing Toolbox and Real-Time EMG and ECG Analysis
    Ozkan, Haydar
    Ural, Ebrar Selva
    Kalender, Aleyna
    Tuncer, Fatma Elif
    2018 MEDICAL TECHNOLOGIES NATIONAL CONGRESS (TIPTEKNO), 2018,
  • [25] Acquisition, Filtering and Decomposition into Real-Time ECG Signal with Ni - MyRio
    Cuzco, L.
    Arias, J.
    Abril, A.
    Cabrera, D.
    2015 CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies (CHILECON), 2015, : 209 - 213
  • [26] Development of Real-Time ECG Signal Monitoring System for Telemedicine Application
    Bashyam, S.
    Ramachandran, B.
    2017 THIRD INTERNATIONAL CONFERENCE ON BIOSIGNALS, IMAGES AND INSTRUMENTATION (ICBSII), 2017,
  • [27] Multithreaded Application for Real-Time Visualization of ECG Signal Waveforms and their Spectrums
    Ilic, S. S.
    Zoric, A. C.
    Spalevic, P.
    Lazic, Lj.
    INTERNATIONAL JOURNAL OF COMPUTERS COMMUNICATIONS & CONTROL, 2013, 8 (04) : 548 - 559
  • [28] Real Time Breathing Signal Measurement: Current Methods
    Grepl, J.
    Penhaker, M.
    Kubicek, J.
    Liberda, A.
    Selamat, A.
    Majernik, J.
    Hudak, R.
    IFAC PAPERSONLINE, 2015, 48 (04): : 153 - 158
  • [29] Technique on real-time measurement of radar pulse signal
    Cui, SH
    Wang, YF
    Fang, X
    ISTM/2001: 4TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2001, : 869 - 872
  • [30] Comparison of real-time specification techniques using a real-time features based framework
    Khwaja, Amir A.
    Urban, Joseph E.
    PROCEEDINGS OF THE 10TH IASTED INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING AND APPLICATIONS, 2006, : 509 - 516