The Comparison Features of ECG Signal with Different Sampling Frequencies and Filter Methods for Real-Time Measurement

被引:15
|
作者
Bui, Ngoc-Thang [1 ,2 ]
Byun, Gyung-su [2 ]
机构
[1] Ho Chi Minh City Univ Technol HUTECH, Inst Engn, 475A Dien Bien Phu St,Ward 25, Ho Chi Minh City 70000, Vietnam
[2] Inha Univ, Sch Informat & Commun Engn, Incheon 22212, South Korea
来源
SYMMETRY-BASEL | 2021年 / 13卷 / 08期
关键词
electrocardiogram (ECG); symmetric finite impulse response (FIR) with odd orders; infinite impulse response (IIR); Arduino ESP32; P wave; QRS wave; T wave; CLASSIFICATION;
D O I
10.3390/sym13081461
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electrocardiogram (ECG) signals have been used to monitor and diagnose signs of cardiovascular disease and abnormal signals about the human body. ECG signals are typically characterized by the PR, QRS, QT interval, ST-segment, and heart rate (HR) parameters. ECG devices are widely used for many applications, especially for the elderly. However, ECG signals are often affected by noises from the environment. There are mainly two types of noises that affect the ECG signals: low frequencies from muscle activity and 50/60 Hz from the electrical grid. Removing these noises is important for improving the quality of the ECG signal. A clear ECG signal makes it easy to diagnose cardiovascular problems. ECG signals with high sampling frequency are more accurate. However, the noises in the signal will be more obvious and it will be difficult to remove these noises with filters. We analyzed the symmetrical correlation between the sampling frequency of the signal and the parameters of the signal such as signal to noise ratio (SNR) and signal amplitude. This study will compare characterization of ECG signals performed at different sampling frequencies before and after applying infinite impulse response (IIR) and symmetric finite impulse response (FIR) filters. Therefore, it is critical that the sampling frequency is consistent at the same frequency of the ECG signal for accurate diagnosis. Furthermore, the approach can be also important for the device to help reduce the device's computing power and hardware resources. Our results were tested with the MIT/ BIH database at 360 Hz sampling frequency with 11-bit resolution. We also experimented with the device operating in real-time with a sampling frequency from 100 Hz to 2133 Hz and a 24-bit resolution. The test results show the advantages of the symmetric FIR filter over IIR when applied to the filtering of ECG signals. The study's conclusions can be applied to real-world devices to improve the quality of ECG signals.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Kalman Filter Based Electromyographic Signal Suppression of Real-Time ECG Signal
    Chen, Meng
    Zhong, Yizhou
    Zhu, Huaiyu
    Pan, Yun
    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45
  • [2] Implementation of a Real-time ECG Signal Processor
    Chien, Shih-Yu Chang
    Hsieh, Cheng-Han
    Lin, Mark Po-Hung
    Fang, Qiang
    Lee, Shuenn-Yuh
    2014 IEEE INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2014,
  • [3] DENOISING AND REMOTE MONITORING OF ECG SIGNAL WITH REAL-TIME EXTENDED KALMAN FILTER IN A WEARABLE SYSTEM
    Ozkaraca, Osman
    Guler, Inan
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2015, 27 (01):
  • [4] Real-time Signal Processing of Data from an ECG
    Iqbal, M. N.
    Bomhara, M.
    Al Khambashi, M.
    Alhassan, H.
    Abd-Alhameed, R.
    Eya, N.
    Qahwaji, R.
    Noras, J. M.
    PROCEEDINGS OF THE 2017 7TH INTERNATIONAL CONFERENCE INTERNET TECHNOLOGIES AND APPLICATIONS (ITA), 2017, : 334 - 338
  • [5] Real-time implementation and comparison of time-varying harmonic measurement methods
    Gherasim, Cristina
    Driesen, Johan
    Belinans, Ronnie
    2006 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION. VOLS 1-5, 2006, : 239 - +
  • [6] Design of A Real-Time ECG Filter for Resource Constraint Computer
    Zhang, Ruyi
    Fang, Xiang
    Liu, Yuanqi
    Liao, Jingsheng
    Li, Baopu
    Meng, Max Q-H
    PROCEEDING OF THE IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2012, : 846 - 849
  • [7] COMPARISON OF METHODS FOR OBTAINING A HEART-RATE-VARIABILITY SIGNAL FROM 60-X REAL-TIME ECG DATA
    BASON, PT
    KITNEY, RI
    JOURNAL OF BIOMEDICAL ENGINEERING, 1981, 3 (03): : 239 - 243
  • [8] Real-time ECG signal transmission via telephone network
    Engin, M
    Çaglav, E
    Engin, EZ
    MEASUREMENT, 2005, 37 (02) : 167 - 171
  • [9] Implementation of a portable device for real-time ECG signal analysis
    Taegyun Jeon
    Byoungho Kim
    Moongu Jeon
    Byung-Geun Lee
    BioMedical Engineering OnLine, 13
  • [10] Distributed Source Coding for Real-Time ECG Signal Monitoring
    Wu, Hung-Tsai
    Tsai, Wei-Ying
    Chang, Wen-Whei
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2014, E97D (08): : 2157 - 2165