A deep learning approach for the automatic recognition of prosthetic mitral valve in echocardiographic images

被引:12
|
作者
Vafaeezadeh, Majid [1 ]
Behnam, Hamid [1 ]
Hosseinsabet, Ali [2 ]
Gifani, Parisa [3 ]
机构
[1] Iran Univ Sci & Technol, Biomed Engn Dept, Tehran, Iran
[2] Univ Tehran Med Sci, Cardiol Dept, Tehran Heart Ctr, Tehran, Iran
[3] Islamic Azad Univ, Med Sci & Technol Dept, Sci & Res Branch, Tehran, Iran
关键词
DCNN; Echocardiographic; Prosthetic mitral valve; EfficientNet; EJECTION FRACTION; NEURAL-NETWORKS; BURNOUT;
D O I
10.1016/j.compbiomed.2021.104388
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The first step in the automatic evaluation of the cardiac prosthetic valve is the recognition of such valves in echocardiographic images. This research surveyed whether a deep convolutional neural network (DCNN) could improve the recognition of prosthetic mitral valve in conventional 2D echocardiographic images. An efficient intervention to decrease the misreading rate of the prosthetic mitral valve is required for non-expert cardiologists. This intervention could serve as a section of a fully-automated analysis chain, alleviate the cardiologist's workload, and improve precision and time management, especially in an emergent situation. Additionally, it might be suitable for pre-labeling large databases of unclassified images. We, therefore, introduce a large publicly-available annotated dataset for the purpose of prosthetic mitral valve recognition. We utilized 2044 comprehensive non-stress transthoracic echocardiographic studies. Totally, 1597 patients had natural mitral valves and 447 patients had prosthetic valves. Each case contained 1 cycle of echocardiographic images from the apical 4-chamber (A4C) and the parasternal long-axis (PLA) views. Thirteen versions of the state-of-the-art models were independently trained, and the ensemble predictions were performed using those versions. For the recognition of prosthetic mitral valves from natural mitral valves, the area under the receiver-operating characteristic curve (AUC) made by the deep learning algorithm was similar to that made by cardiologists (0.99). In this research, EfficientNetB3 architecture in the A4C view and the EfficientNetB4 architecture in the PLA view were the best models among the other pre-trained DCNN models.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Deep learning-based automatic recognition network of agricultural machinery images
    Zhang, Ziqiang
    Liu, Hui
    Meng, Zhijun
    Chen, Jingping
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2019, 166
  • [32] A Deep Learning Approach for Valve Defect Recognition in Heart Acoustic Signal
    Kucharski, Dariusz
    Grochala, Dominik
    Kajor, Marcin
    Kantoch, Eliasz
    INFORMATION SYSTEMS ARCHITECTURE AND TECHNOLOGY, PT I, 2018, 655 : 3 - 14
  • [33] Automatic Segmentation of River and Land in SAR Images: A Deep Learning Approach
    Pai, Manohara M. M.
    Mehrotra, Vaibhav
    Aiyar, Shreyas
    Verma, Ujjwal
    Pai, Radhika M.
    2019 IEEE SECOND INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND KNOWLEDGE ENGINEERING (AIKE), 2019, : 15 - 20
  • [34] TRANSESOPHAGEAL ECHOCARDIOGRAPHIC RECOGNITION OF MITRAL-VALVE ABNORMALITIES ASSOCIATED WITH AORTIC-VALVE ENDOCARDITIS
    KARALIS, DG
    CHANDRASEKARAN, K
    WAHL, JM
    MINTZ, GS
    AMERICAN HEART JOURNAL, 1990, 119 (05) : 1209 - 1211
  • [35] Echocardiographic Assessment of the Mitral Valve for Suitability of Repair: An Intraoperative Approach From a Mitral Center
    Mahmood, Feroze
    Sharkey, Aidan
    Maslow, Andrew
    Mufarrih, Syed Hamza
    Qureshi, Nada Qaisar
    Matyal, Robina
    Khabbaz, Kamal R.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (07) : 2164 - 2176
  • [36] A deep learning approach for automatic speech recognition of The Holy Qur'an recitations
    Tantawi, Imad K.
    Abushariah, Mohammad A. M.
    Hammo, Bassam H.
    INTERNATIONAL JOURNAL OF SPEECH TECHNOLOGY, 2021, 24 (04) : 1017 - 1032
  • [37] Intraoperative transesophageal echocardiographic assessment of acute prosthetic aortic valve regurgitation after mitral valve replacement: Value of the deep transgastric long-axis view
    Koh, TW
    Gandhi, S
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (12) : 1538 - 1540
  • [38] ECHOCARDIOGRAPHIC STUDY OF MALFUNCTION OF BJORK-SHILEY PROSTHETIC HEART-VALVE IN MITRAL POSITION
    BERNALRAMIREZ, JA
    PHILLIPS, JH
    AMERICAN JOURNAL OF CARDIOLOGY, 1977, 40 (03): : 449 - 453
  • [39] ECHOCARDIOGRAPHIC DIAGNOSIS OF MALFUNCTION OF THE BJORK-SHILEY PROSTHETIC HEART-VALVE IN THE MITRAL POSITION
    WISSKIRCHEN, K
    MATTERN, H
    FRICKE, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 1979, 68 (01): : 21 - 25
  • [40] Normal echocardiographic characteristics of the Sorin Bicarbon bileaflet prosthetic heart valve in the mitral and aortic positions
    Badano, L
    Mocchegiani, R
    Bertoli, D
    DeGaetano, G
    Carratino, L
    Pasetti, L
    Caudullo, M
    Budini, A
    Mannello, B
    Passerone, G
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (06) : 632 - 643