In vivo identification of uric acid stones with dual-energy CT: diagnostic performance evaluation in patients

被引:83
|
作者
Stolzmann, Paul [1 ]
Kozomara, Marko [2 ]
Chuck, Natalie [1 ]
Muentener, Michael [2 ]
Leschka, Sebastian [1 ]
Scheffel, Hans [1 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Urol, CH-8091 Zurich, Switzerland
来源
ABDOMINAL IMAGING | 2010年 / 35卷 / 05期
基金
瑞士国家科学基金会;
关键词
Dual energy; Computed tomography; Uric acid; Urinary stone; In vivo; Crystallography; SHOCK-WAVE LITHOTRIPSY; COMPUTED-TOMOGRAPHY; URINARY CALCULI; URETERAL CALCULI; MULTIDETECTOR CT; KIDNEY-STONES; HELICAL CT; DIFFERENTIATION; EXPERIENCE; DISEASE;
D O I
10.1007/s00261-009-9569-9
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
To prospectively investigate the in vivo diagnostic performance of dual-energy (DE) computed tomography (CT) for the differentiation between uric acid (UA)-containing and non-UA-containing urinary stones. DE CT scans were performed in 180 patients with suspected urinary stone disease using a dual-source CT scanner in the DE mode (tube voltages 80 and 140 kV). Urinary stones were classified as UA-containing or non-UA-containing based on CT number measurements and DE software results. Sensitivity, specificity, positive predictive values (PPV), and negative predictive values (NPV) for the detection of UA-containing urinary stones were calculated using the crystallographic stone analysis as the reference standard. DE CT detected 110/180 patients (61%) with urinary stone disease. In 53 patients, stones were sampled. Forty-four out of 53 stones (83%) were non-UA-containing; and nine stones (17%) were UA-containing. The software automatically mapped 52/53 (98%) stones. One non-UA-containing stone (UA, 2 mm) was missed; one UA-containing stone (3 mm) was misclassified by software analysis. The sensitivity, specificity, PPV, and NPV for the detection of UA-containing stones was 89% (8/9, 95% CI: 52-100%), 98% (43/44, 95% CI: 88-100%), 89% (8/9, 95% CI: 52-100%), and 98% (43/44, 95% CI: 88-100%). Our results indicate that DE dual-source CT permits for the accurate in vivo differentiation between UA-containing and non-UA-containing urinary stones.
引用
下载
收藏
页码:629 / 635
页数:7
相关论文
共 50 条
  • [21] Split-bolus dual-energy CT urography: protocol optimization and diagnostic performance for the detection of urinary stones
    Christoph A. Karlo
    Ralph Gnannt
    Anna Winklehner
    Michael A. Fischer
    Olivio F. Donati
    Daniel Eberli
    Tullio Sulser
    Hatem Alkadhi
    Paul Stolzmann
    Abdominal Imaging, 2013, 38 : 1136 - 1143
  • [22] Split-bolus dual-energy CT urography: protocol optimization and diagnostic performance for the detection of urinary stones
    Karlo, Christoph A.
    Gnannt, Ralph
    Winklehner, Anna
    Fischer, Michael A.
    Donati, Olivio F.
    Eberli, Daniel
    Sulser, Tullio
    Alkadhi, Hatem
    Stolzmann, Paul
    ABDOMINAL IMAGING, 2013, 38 (05): : 1136 - 1143
  • [23] Evaluation of image quality, radiation dose and diagnostic performance of dual-energy CT datasets in patients with hepatocellular carcinoma
    Anzidei, M.
    Di Martino, M.
    Sacconi, B.
    Saba, L.
    Boni, F.
    Zaccagna, F.
    Geiger, D.
    Kirchin, M. A.
    Napoli, A.
    Bezzi, M.
    Catalano, C.
    CLINICAL RADIOLOGY, 2015, 70 (09) : 966 - 973
  • [24] Dual-Energy Dual-Source CT With Additional Spectral Filtration Can Improve the Differentiation of Non-Uric Acid Renal Stones: An Ex Vivo Phantom Study
    Qu, Mingliang
    Ramirez-Giraldo, Juan C.
    Leng, Shuai
    Williams, James C.
    Vrtiska, Terri J.
    Lieske, John C.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : 1279 - 1287
  • [25] Negative gallbladder stones: Diagnostic advantages of dual-energy CT and analysis of a unique case
    Wang, Fengyan
    Wang, Shuling
    Gong, Weiyi
    ASIAN JOURNAL OF SURGERY, 2024, 47 (05) : 2347 - 2348
  • [26] Evaluation of split-filter dual-energy CT for characterization of urinary stones
    Appel, Elisabeth
    Thomas, Christoph
    Steuwe, Andrea
    Schaarschmidt, Benedikt M.
    Brook, Olga R.
    Aissa, Joel
    Hennenlotter, Joerg
    Antoch, Gerald
    Boos, Johannes
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1127):
  • [27] The diagnostic performance of dual-energy CT and SPECT. Is dual-energy CT truly superior to SPECT in diagnosis of pulmonary embolism?
    Kosuda, S.
    Kawana, A.
    Kyoto, Y.
    Naoi, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S386 - S386
  • [28] Stones: Low-dose dual-energy CT
    Payton S.
    Nature Reviews Urology, 2011, 8 (1) : 7 - 7
  • [29] Dual-Energy CT for Diagnostic CT Colonography Response
    Cai, Wenli
    Lee, June-Goo
    Yoshida, Hiroyuki
    Kim, Se Hyung
    RADIOGRAPHICS, 2014, 34 (03)
  • [30] Usefulness of dual-energy computed tomography with and without dedicated software in identifying uric acid kidney stones
    Salvador, R.
    Luque, M. P.
    Ciudin, A.
    Pano, B.
    Bunesch, L.
    Sebastia, C.
    Nicolau, C.
    RADIOLOGIA, 2016, 58 (02): : 120 - 128