Development and Validation of a Sensitive LC-MS-MS Method for the Determination of Adefovir in Human Serum and Urine: Application to a Clinical Pharmacokinetic Study

被引:2
|
作者
Zhang, Ye [1 ]
Shen, Lu [1 ]
Zhan, Ying [2 ]
Xiao, Qing-Qing [3 ]
Yang, Jin [1 ]
机构
[1] China Pharmaceut Univ, Ctr Drug Metab & Pharmacokinet, 24 Tong Jia Xiang, Nanjing, Jiangsu, Peoples R China
[2] Southeast Univ, Zhongda Hosp, Dept Pharm, 87 Ding Jia Qiao, Nanjing 210009, Peoples R China
[3] China Pharmaceut Univ, Dept Clin Pharm, 24 Tong Jia Xiang, Nanjing 210009, Peoples R China
关键词
CHROMATOGRAPHY/TANDEM MASS-SPECTROMETRY; HUMAN PLASMA; PRODRUGS; PMEA; VOLUNTEERS; PRADEFOVIR; DELIVERY; LIVER; DRUG;
D O I
10.1093/chromsci/bmv172
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of adefovir (PMEA, 9-(2-phosphonylmethoxyethyl) adenine) concentration in human serum and urine. The analysis was performed on a negative ionization electrospray mass spectrometer via multiple reaction monitoring. The monitored transitions were set atm/z 272.0 -> 134.0 and m/z 276.0 -> 149.8 for PMEA and internal standard, respectively. After protein precipitation, samples were separated by high-performance liquid chromatography on a reversed-phase Dikma Diamonsil C18 (250 x 4.6 mm; 5 mu m) column with a mobile phase of 0.1 mM ammonium formate buffer-methanol. The calibration curves were linear over the serum concentration range 0.5-1,000 ng/mL and urine concentration range 2.0-1,000 ng/mL. The intra-and interday precision values of PMEA in both serum and urine were lower than 18.16% for low quality control and 13.70% for medium and high quality control. The accuracy, recovery, matrix factor and stability were also within the acceptable limits. The developed method was successfully applied to the pharmacokinetic study of following oral administration of single dose of pradefovir mesylate (10, 30, 60, 90 and 120 mg) and adefovir dipivoxil (10 mg) to healthy Chinese volunteers.
引用
收藏
页码:507 / 515
页数:9
相关论文
共 50 条
  • [41] DETERMINATION OF RALOXIFENE HYDROCHLORIDE IN HUMAN URINE BY LC-MS-MS
    Kumar, Urdigere R. Anil
    Basavaiah, Kanakapura
    Tharpa, Kalsang
    Vinay, Kanakapura B.
    [J]. CHEMICAL INDUSTRY & CHEMICAL ENGINEERING QUARTERLY, 2009, 15 (03) : 119 - 123
  • [42] Development and Validation of an LC-MS-MS Method for the Simultaneous Determination of Simvastatin, Simvastatin Acid and Ezetimibe in Human Plasma and Its Application to Pharmacokinetic Study in the Indian Population
    Munaga, Sathish Babu
    Valluru, Rajani Kumar
    Bonga, Phani Bhushana Reddy
    Rao, V. Sumathi
    Sharma, Hemanth Kumar
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (06) : 985 - 996
  • [43] Development and validation of an LC-MS/MS method for determination of methanesulfonamide in human urine
    Anacardio, Roberto
    Mullins, Frank G. P.
    Hannam, Sally
    Sheikh, Muhammed S.
    O'Shea, Karen
    Aramini, Andrea
    D'Anniballe, Gaetano
    D'Anteo, Loredana
    Ferrari, Mauro P.
    Allegretti, Marcello
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (22): : 2087 - 2092
  • [44] Development and validation of a highly sensitive LC-MS/MS method for quantitation of dexlansoprazole in human plasma: application to a human pharmacokinetic study
    Hotha, Kishore Kumar
    Bharathi, D. Vijaya
    Jagadeesh, B.
    Ravindranath, L. K.
    Veera, K. N. Jaya
    Venkateswarulu, V.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (02) : 192 - 198
  • [45] Development and validation of a highly sensitive LC-MS/MS method for quantitation of bivalirudin in human plasma: application to a human pharmacokinetic study
    Chai, Dong
    Wang, Rui
    Bai, Nan
    Cai, Yun
    Liang, Beibei
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (12) : 1788 - 1793
  • [46] LC-MS-MS Development and Validation for Quantitative Determination of Methoxsalen in Human Plasma
    Gomes, Noel Alex
    Vaidya, Vikas V.
    Pudage, Ashutosh M.
    Joshi, Santosh S.
    Laud, Avdhoot M.
    Basagare, Snehal
    Tandel, Jayram A.
    [J]. CHROMATOGRAPHIA, 2009, 69 (9-10) : 1061 - 1065
  • [47] Rapid and Sensitive LC-MS-MS Method for the Determination of Sarpogrelate in Human Plasma
    Patankar, Siddheshwar
    Pudage, Ashutosh
    Joshi, Santosh S.
    Vaidya, Vikas V.
    Gomes, Noel A.
    [J]. CHROMATOGRAPHIA, 2009, 69 (7-8) : 671 - 676
  • [48] Fumonisins determination in urine by LC-MS-MS
    Silva, Liliana J. G.
    Pena, Angelina
    Lino, Celeste M.
    Fernandez, Monica F.
    Manes, Jordi
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (02) : 809 - 816
  • [49] LC-MS-MS Development and Validation for Quantitative Determination of Methoxsalen in Human Plasma
    Noel Alex Gomes
    Vikas V. Vaidya
    Ashutosh M. Pudage
    Santosh S. Joshi
    Avdhoot M. Laud
    Snehal Basagare
    Jayram A. Tandel
    [J]. Chromatographia, 2009, 69 : 1061 - 1065
  • [50] Fumonisins determination in urine by LC-MS-MS
    Liliana J. G. Silva
    Angelina Pena
    Celeste M. Lino
    Mónica F. Fernández
    Jordi Mañes
    [J]. Analytical and Bioanalytical Chemistry, 2010, 396 : 809 - 816