Data-driven method of pile-up correction for the substructure of massive jets

被引:19
|
作者
Alon, Raz [1 ]
Duchovni, Ehud [1 ]
Perez, Gilad [1 ]
Pranko, Aliaksandr P. [2 ]
Sinervo, Pekka K. [3 ]
机构
[1] Weizmann Inst Sci, Dept Particle Phys & Astrophys, IL-76100 Rehovot, Israel
[2] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[3] Univ Toronto, Dept Phys, Toronto, ON M5S 1A7, Canada
来源
PHYSICAL REVIEW D | 2011年 / 84卷 / 11期
基金
加拿大自然科学与工程研究理事会; 以色列科学基金会; 欧盟第七框架计划;
关键词
D O I
10.1103/PhysRevD.84.114025
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We describe a method to measure and correct for the incoherent component of energy flow arising from multiple interactions from jet shape and substructure observables of massive jets. The correction is a function of the jet-shape variable of interest and not a universal property. Such a correction is expected to reduce biases in the corresponding distributions generated by the presence of multiple interactions and to improve measurement resolution. This data-driven technique is not subject to uncertainties coming from the use of theoretical calculations. Corrections are derived for jet mass, angularity, and planar flow, and are found to be in good agreement with data on massive jets observed by the CDF collaboration. Finally, we comment on the linkage with the concept of jet area and jet mass area.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Technique for Recovering Pile-Up Events from Microcalorimeter Data
    Wulf, D.
    Jaeckel, F.
    McCammon, D.
    Morgan, K. M.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2016, 184 (1-2) : 431 - 435
  • [32] High count rate gamma ray pile-up correction method of NaI(Tl) detector based on deconvolution method
    Zuo, Jingxin
    Yang, Chaowen
    Shao, Weihao
    Bai, Lixin
    Song, Yun
    Han, Bing
    Liang, Yongfei
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1061
  • [33] A METHOD TO CORRECT AMPLITUDE DISTORTIONS DUE TO PILE-UP EFFECTS
    DELOTTO, I
    DOTTI, D
    MARIOTTI, D
    NUCLEAR INSTRUMENTS & METHODS, 1966, 40 (01): : 169 - &
  • [34] Implementation and Performance Analysis of Pulse Pile-up Correction Algorithm on DSP architecture
    Chi, Tao
    Chen, Ming
    Zhang, Dingsong
    PROCEEDINGS OF 2015 IEEE 5TH INTERNATIONAL CONFERENCE ON ELECTRONICS INFORMATION AND EMERGENCY COMMUNICATION, 2015, : 372 - 375
  • [35] Pile-up correction algorithm for high count rate gamma ray spectroscopy
    Hammad, M. E.
    Kasban, H.
    Fikry, R. M.
    Dessoky, Moawad, I
    Zahran, O.
    Elaraby, Sayed M. S.
    Abd El-Samie, Fathi E.
    APPLIED RADIATION AND ISOTOPES, 2019, 151 : 196 - 206
  • [36] Transformer algorithm for pile-up correction in synchrotron radiation spectroscopic detection experiments
    Wang, Shoupeng
    Pan, Nan
    Gu, Songqi
    Wang, Yu
    Huang, Yuying
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [37] Pile-up correction for improved accuracy and speed of x-ray analysis
    Statham, Peter J.
    MICROCHIMICA ACTA, 2006, 155 (1-2) : 289 - 294
  • [38] Pile-up Correction Techniques for Real-Time Dosimetry in Photon Radiotherapy
    Miklavec, Mojca
    Loeher, Bastian
    Savran, Deniz
    Novak, Roman
    Sirca, Simon
    Vencelj, Matjaz
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3880 - 3882
  • [39] Energy spectrum reconstruction for HPGE detectors using analytical pile-up correction
    Trigano, T.
    Roueff, F.
    Moulines, E.
    Souloumiac, A.
    Montagu, T.
    2006 IEEE International Conference on Acoustics, Speech and Signal Processing, Vols 1-13, 2006, : 3043 - 3046
  • [40] Pile-Up Correction for Improved Accuracy and Speed of X-Ray Analysis
    Peter J. Statham
    Microchimica Acta, 2006, 155 : 289 - 294