Thermal lesion conspicuity following interstitial radiofrequency thermal tumor ablation in humans: A comparison of STIR, turbo spin-echo T2-weighted, and contrast-enhanced T1-weighted MR images at 0.2 T

被引:0
|
作者
Aschoff, AJ [1 ]
Rafie, N [1 ]
Jesberger, JA [1 ]
Duerk, JL [1 ]
Lewin, JS [1 ]
机构
[1] Case Western Reserve Univ, Dept Radiol, Univ Hosp Cleveland, Cleveland, OH 44106 USA
关键词
intervention; radiofrequency; interstitial thermotherapy; liver; MRI;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare the contrast between radiofrequency (RF) thermal liver lesions and surrounding tissue In T2-weighted turbo spin-echo sequences (TSE T2), short T1 inversion recovery techniques (STIR), and contrast-enhanced (CE) T1-weighted spin-echo images. Nineteen RF thermal ablations were performed on eight patients with metastatic liver tumors. After ablation, contrast-to-noise ratios (CNRs) were calculated between mean signal amplitudes from three regions of interest (ROI) (lesion, surrounding edema, and normal tissue) using TSE T2-weighted, STIR, and contrast-enhanced T1-weighted (CE T1) sequences for each lesion. CNRs between the thermal lesion and normal liver tissue for both TSE T2-weighted (mean 0.9) and STIR (2.0) Images were significantly lower than for CE T1-weighted (8.4) Images (t-test, alpha = 0.05). However, CNRs between edema rim and the core of the thermal lesion for both TSE T2-weighted (8.1) and STIR images (7.2) were not significantly different (t-test, a = 0.05) from CNRs between lesion and normal tissue for CE T1-weighted images (8.4), nor was the CNR between edema rim and normal tissue for both TSE T2-weighted (10.3) and STIR (9.8) Images. Although the edema was not visible on CE TI-weighted images, 18 of 19 lesions (94.7%) were surrounded by a hyperintense rim on TSE T2-weighted or STIR images. Both TSE T2-weighted and STIR sequences represent valid techniques for repeatable assessment of RF thermal lesions. J. Magn. Reson. Imaging 2000; 12:584-589. (C) 2000 Wiley-Liss, Inc.
引用
收藏
页码:584 / 589
页数:6
相关论文
共 50 条
  • [31] Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence
    Shinji Naganawa
    Hiroko Satake
    Shingo Iwano
    Hisashi Kawai
    Seiji Kubota
    Tomohiro Komada
    Minako Kawamura
    Yasuo Sakurai
    Hiroshi Fukatsu
    European Radiology, 2008, 18
  • [32] Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence
    Naganawa, Shinji
    Satake, Hiroko
    Iwano, Shingo
    Kawai, Hisashi
    Kubota, Seiji
    Komada, Tomohiro
    Kawamura, Minako
    Sakurai, Yasuo
    Fukatsu, Hiroshi
    EUROPEAN RADIOLOGY, 2008, 18 (02) : 337 - 342
  • [33] Comparison of Spin-Echo T1-and T2-Weighted and Gradient-Echo T1-Weighted Images at 3T in Evaluating Very Preterm Neonates at Term-Equivalent Age
    Sarikaya, B.
    McKinney, A. M.
    Spilseth, B.
    Truwit, C. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (05) : 1098 - 1103
  • [34] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [35] Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT
    G. A. Krombach
    T. Schmitz-Rode
    P. Haage
    E. DiMartino
    A. Prescher
    S. Kinzel
    R. W. Günther
    Neuroradiology, 2004, 46 : 326 - 331
  • [36] Semicircular canal dehiscence:: comparison of T2-weighted turbo spin-echo MRI and CT
    Krombach, GA
    Schmitz-Rode, T
    Haage, P
    DiMartino, E
    Prescher, A
    Kinzel, S
    Günther, RW
    NEURORADIOLOGY, 2004, 46 (04) : 326 - 331
  • [37] T2-WEIGHTED MR-IMAGING OF THE CHEST - COMPARISON OF ELECTROCARDIOGRAPH-TRIGGERED CONVENTIONAL AND TURBO SPIN-ECHO AND NONTRIGGERED TURBO SPIN-ECHO SEQUENCES
    HADDAD, JL
    ROFSKY, NM
    AMBROSINO, MM
    NAIDICH, DP
    WEINREB, JC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 325 - 329
  • [38] Differentiation of Pelvic Osteosarcoma and Ewing Sarcoma Using Radiomic Analysis Based on T2-Weighted Images and Contrast-Enhanced T1-Weighted Images
    Dai, Yi
    Yin, Ping
    Mao, Ning
    Sun, Chao
    Wu, Jiangfen
    Cheng, Guanxun
    Hong, Nan
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [39] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182
  • [40] T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging
    Dohan, Anthony
    Gavini, Jean-Philippe
    Place, Vinciane
    Sebbag, Delphine
    Vignaud, Alexandre
    Herbin, Christine
    Hamzi, Lounis
    Boudiaf, Mourad
    Soyer, Philippe
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E655 - E661