Noninvasive, real time laser Doppler flowmetry in perfusion regions and larger vessels

被引:1
|
作者
Elter, P [1 ]
Seiter, E [1 ]
Karch, T [1 ]
Stork, W [1 ]
Müller-Glaser, KD [1 ]
Lutter, N [1 ]
机构
[1] Univ Karlsruhe, Inst Tech Informat Verarbeitung, Karlsruhe, Germany
关键词
laser; Doppler; flowmetry; real time; autoregressive;
D O I
10.1117/12.336946
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This paper describes an enhanced noninvasive continuous laser Doppler system for real time blood flow measurements in perfusion regions and larger vessels. The system consists of a miniaturized sensor, a fast digital signal processing (DSP) unit and a PC for signal visualization. The sensor comprises an IR laser diode to illuminate tissue through a short optical fiber with a variable spot size of 400 mu m to 1000 mu m and a photodetector which can be positioned 3 mm to 7 mm from the laser spot. The DSP of the system uses a parametric estimation of the laser Doppler power spectrum density based on a first order autoregressive process model BR(1) to calculate the first weighted moment. This algorithm is approx, ten times faster and as accurate as equivalent FFT based algorithms. With a sampling rate of 390 kHz it is possible to calculate and visualize 85 flow values per second. Model measurements prove very high linear correlations (r greater than or equal to 0.99) between calculated first moments and flow velocities in a range from 1 mm/s up to 120 mm/s. Furthermore, in vivo measurements of blood flow both in perfusion regions and larger arteries such as the a. radialis were successfully performed in real time.
引用
收藏
页码:244 / 254
页数:11
相关论文
共 50 条
  • [21] THE SIGNIFICANCE OF PROBE DESIGN IN EVALUATION OF COLONIC PERFUSION WITH LASER-DOPPLER FLOWMETRY
    KROHGSORENSEN, K
    LINE, PD
    KVERNEBO, K
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1993, 28 (05) : 381 - 386
  • [22] ASSESSMENT OF MYOCARDIAL PERFUSION IN THE EMPTY BEATING PORCINE HEART WITH LASER DOPPLER FLOWMETRY
    AHN, HC
    EKROTH, R
    HEDENMARK, J
    NILSSON, GE
    SVEDJEHOLM, R
    CARDIOVASCULAR RESEARCH, 1988, 22 (10) : 719 - 725
  • [23] Pulsed-laser Doppler flowmetry provides basis for deep perfusion probing
    Kolkman, RGM
    Hondebrink, E
    Bolt, RA
    Steenbergen, W
    de Mul, FFM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (11): : 4242 - 4244
  • [24] Laser doppler flowmetry and transcutaneous oximetry, complementary methods to evaluate skin perfusion
    Potocnik, Ivana
    Potocnik, Nejka
    ACTA PHYSIOLOGICA, 2023, 239
  • [25] AN INVITRO ANALYSIS OF 2 LASER DOPPLER FLOWMETRY SYSTEMS FOR EVALUATION OF BONE PERFUSION
    CARPENTER, GK
    SWIONTKOWSKI, MF
    CALCIFIED TISSUE INTERNATIONAL, 1991, 48 (06) : 414 - 420
  • [26] DOES LASER-DOPPLER FLOWMETRY PROVIDE A QUANTITATIVE MEASURE OF HEPATIC PERFUSION
    WHEATLEY, AM
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (05): : G960 - G961
  • [27] Importance of wavelet analysis in laser Doppler flowmetry time series
    Bernjak, Alan
    Stefanovska, Aneta
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4064 - 4067
  • [28] Detrended fluctuation analysis of laser Doppler flowmetry time series
    Esen, Ferhan
    Aydin, Guelsuen Soenmez
    Esen, Hamza
    MICROVASCULAR RESEARCH, 2009, 78 (03) : 314 - 318
  • [29] LASER DOPPLER FLOWMETRY - A NEW TECHNIQUE FOR NONINVASIVE ASSESSMENT OF SKIN BLOOD-FLOW
    NILSSON, GE
    SALERUD, EG
    TENLAND, T
    OBERG, PA
    WAHLBERG, JE
    COSMETICS & TOILETRIES, 1984, 99 (03): : 97 - &
  • [30] CONTINUOUS REAL-TIME LASER-DOPPLER ANALYSIS SYSTEM FOR OCULAR FUNDUS FLOWMETRY AND VELOCIMETRY
    PETRIG, BL
    RIVA, CE
    CRANSTOUN, SD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1402 - 1402