Determination of the hydrogen sensitivity and depth resolution of medium-energy, time-of-flight, forward-recoil spectrometry

被引:3
|
作者
Arps, JH [1 ]
Weller, RA [1 ]
机构
[1] VANDERBILT UNIV,STN B,NASHVILLE,TN 37235
关键词
D O I
10.1016/S0168-583X(96)00458-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Medium energy time-of-flight forward recoil spectrometry has been developed recently as a complement to conventional ion beam analysis methods such as nuclear reaction analysis and elastic recoil detection. Here we report measurements of the minimum detectable surface concentration and near surface depth resolution for hydrogen by forward recoil spectrometry using a number of beam species and energies. The primary physical limitations encountered in these measurements are identified and discussed. Using an 810 keV Ar3+ beam, H on a carbon substrate can, in principle, be detected at areal densities as low as 1X10(13) H/cm(2). A 540 keV O2+ beam has been found to be a suitable choice for depth profiling of H in Si achieving a resolution of approximately 6 nm near the surface. Examples are given which demonstrate the utility of the technique for hydrogen profiling.
引用
收藏
页码:527 / 532
页数:6
相关论文
共 50 条
  • [21] Analysis technique for ultra shallow junction using medium energy ion scattering time-of-flight elastic recoil detection analysis
    Abo, Satoshi
    Pei, Ri
    Yuan, Yao Xin
    Wakaya, Fujio
    Takai, Mikio
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 (12-13) : 1192 - 1195
  • [22] Identification and determination of mycotoxins and food additives in feed by HPLC-high-resolution time-of-flight mass spectrometry
    Amelin, V. G.
    Timofeev, A. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (04) : 410 - 417
  • [23] Identification and determination of mycotoxins and food additives in feed by HPLC–high-resolution time-of-flight mass spectrometry
    V. G. Amelin
    A. A. Timofeev
    Journal of Analytical Chemistry, 2016, 71 : 410 - 417
  • [24] Quantitative hydrogen analysis through time of flight-elastic recoil detection analysis using medium energy ions
    Park, Kyungsu
    Kim, Jwa Soon
    An, Sung Yup
    Jung, Kwang Hwan
    Kim, Soobang
    Yu, Kyu-Sang
    Min, Won Ja
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 450 : 310 - 314
  • [25] Construction of high-resolution energy—time-of-flight spectrometer for determination of fission fragment mass distributions
    Chao Liu
    Shilong Liu
    Yi Yang
    Radiation Detection Technology and Methods, 2022, 6 : 102 - 110
  • [26] Are cluster ion analysis beams good choices for hydrogen depth profiling using time-of-flight secondary ion mass spectrometry?
    Zhu, Zihua
    Shutthanandan, Vaithiyalingam
    SURFACE AND INTERFACE ANALYSIS, 2012, 44 (01) : 89 - 93
  • [27] Determination of stimulants using gas chromatography/high-resolution time-of-flight mass spectrometry and a soft ionization source
    Lopez-Avila, Viorica
    Cooley, James
    Urdahl, Randall
    Thevis, Mario
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (23) : 2714 - 2724
  • [28] Determination of fat-soluble components in Danshen by high-resolution electrospray ionization time-of-flight mass spectrometry
    Yu, WJ
    He, J
    Shen, JC
    Wang, XR
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (04): : 621 - 623
  • [29] Sensitive multi-element profiling with high depth resolution enabled by time-of-flight recoil detection in transmission using pulsed keV ion beams
    Holenak, R.
    Lohmann, S.
    Primetzhofer, D.
    VACUUM, 2022, 204
  • [30] THE PHOTODISSOCIATION OF METHYL-IODIDE AT 229.4 NM - A DETERMINATION OF THE FRAGMENT RECOIL ANISOTROPY USING ENERGY-SELECTIVE ELECTRON-IMPACT IONIZATION AND TIME-OF-FLIGHT MASS-SPECTROMETRY
    PENN, SM
    HAYDEN, CC
    MUYSKENS, KJC
    CRIM, FF
    JOURNAL OF CHEMICAL PHYSICS, 1988, 89 (05): : 2909 - 2917