Variability in echocardiographic measurements of left ventricular function in septic shock patients

被引:35
|
作者
De Geer, Lina [1 ,2 ]
Oscarsson, Anna [1 ,2 ]
Engvall, Jan [2 ,3 ]
机构
[1] Linkoping Univ, Dept Intens Care, Linkoping, Sweden
[2] Linkoping Univ, Dept Med & Hlth Sci, Linkoping, Sweden
[3] Linkoping Univ, Dept Clin Physiol, Linkoping, Sweden
关键词
Echocardiography; Heart failure; Intensive care; Interobserver reliability; Repeatability; Shock; Septic; SEVERE SEPSIS; DIASTOLIC FUNCTION; DOPPLER-ECHOCARDIOGRAPHY; EJECTION FRACTION; SYSTOLIC FUNCTION; SPECKLE-TRACKING; FILLING PRESSURE; CRITICALLY-ILL; RECOMMENDATIONS; DYSFUNCTION;
D O I
10.1186/s12947-015-0015-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Echocardiography is increasingly used for haemodynamic evaluation and titration of therapy in intensive care, warranting reliable and reproducible measurements. The aim of this study was to evaluate the observer dependence of echocardiographic findings of left ventricular (LV) diastolic and systolic dysfunction in patients with septic shock. Methods: Echocardiograms performed in 47 adult patients admitted with septic shock to a general intensive care unit (ICU) were independently evaluated by one cardiologist and one intensivist for the following signs: decreased diastolic tissue velocity of the base of the LV septum (e), increased early mitral inflow (E) to e ratio (E/e), decreased LV ejection fraction (EF) and decreased LV global longitudinal peak strain (GLPS). Diastolic dysfunction was defined as e <8.0 cm/s and/or E/e >= 15 and systolic dysfunction as EF <50% and/or GLPS > -15%. Ten randomly selected examinations were re-analysed two months later. Pearson's r was used to test the correlation and Bland-Altman plots to assess the agreement between observers. Kappa statistics were used to test the consistency between readers and intraclass correlation coefficients (ICC) for inter- and intraobserver variability. Results: In 44 patients (94%), image quality was sufficient for echocardiographic measurements. The agreement between observers was moderate (k = 0.60 for e, k = 0.50 for E/e and k = 0.60 for EF) to good (k = 0.71 for GLPS). Pearson's r was 0.76 for e, 0.85 for E/e, 0.78 for EF and 0.84 for GLPS (p < 0.001 for all four). The ICC between observers for e was very good (0.85; 95% confidence interval (CI) 0.73-0.92), good for E/e (0.70; 95% CI 0.45 - 0.84), very good for EF (0.87; 95% CI 0.77 - 0.93), excellent for GLPS (0.91; 95% CI 0.74 - 0.95), and very good for all measures repeated by one of the observers. On Bland-Altman analysis, the mean differences and 95% limits of agreement for e, E/e, EF and GLPS were -0.01 (0.04 - 0.07), 2.0 (-14.2 - 18.1), 0.86 (-16 - 14.3) and 0.04 (-5.04 - 5.12), respectively. Conclusions: Moderate observer-related differences in assessing LV dysfunction were seen. GLPS is the least user dependent and most reproducible echocardiographic measurement of LV function in septic shock.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Left ventricular diastolic dysfunction is prevalent but not associated with mortality in patients with septic shock
    Vignon, Philippe
    Charron, Cyril
    Legras, Annick
    Musset, Frederique
    Slama, Michel
    Prat, Gwenael
    Silva, Stein
    Vandroux, David
    Mueller, Gregoire
    Levy, Bruno
    Boissier, Florence
    Evrard, Bruno
    Goudelin, Marine
    Mankikian, Stefan
    Nay, Mai-Anh
    Jabot, Julien
    Riu, Beatrice
    Bailly, Pierre
    Maizel, Julien
    Leger, Julie
    Vieillard-Baron, Antoine
    CRICS-TRIGGERSEP Network
    INTENSIVE CARE MEDICINE, 2025, 51 (01) : 94 - 105
  • [42] Vasopressin in Patients with Septic Shock and Dynamic Left Ventricular Outflow Tract Obstruction
    Balik, Martin
    Novotny, Adam
    Suk, Daniel
    Matousek, Vojtech
    Maly, Michal
    Brozek, Tomas
    Tavazzi, Guido
    CARDIOVASCULAR DRUGS AND THERAPY, 2020, 34 (05) : 685 - 688
  • [43] Echocardiographic assessment of left ventricular diastolic function in elderly hypertensive patients
    Takasaki, M
    Matsumoto, M
    Deng, YB
    CARDIOLOGY IN THE ELDERLY, 1996, 4 (5-6): : 185 - 189
  • [44] Doppler echocardiographic study of left ventricular diastolic function in hemodialysis patients
    Ben Khalfallah, A
    Ghodhbane, L
    Tlili, R
    Annabi, N
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2005, 98 (01): : 31 - 38
  • [45] LEFT-VENTRICULAR FUNCTION IN UREMIC PATIENTS IN HEMODIALYSIS - ECHOCARDIOGRAPHIC STUDY
    FERNANDEZ, PG
    FERRUFINO, O
    OLIVER, J
    CONESA, J
    CARBALLADA, AT
    GUTIERREZ, RS
    SICILIA, LS
    MEDICINA CLINICA, 1983, 80 (07): : 304 - 307
  • [46] ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR FUNCTION IN PATIENTS WITH CHRONIC UREMIA
    COHEN, MV
    DIAZ, P
    SCHEUER, J
    CLINICAL NEPHROLOGY, 1979, 12 (04) : 156 - 162
  • [47] RIGHT VENTRICULAR-FUNCTION IN SEPTIC SHOCK
    REUSE, C
    FRANK, N
    CONTEMPRE, B
    VINCENT, JL
    INTENSIVE CARE MEDICINE, 1988, 14 : 486 - 487
  • [48] Echocardiographic Assessment of Left Ventricular Systolic and Diastolic Functions in Dogs with Severe Sepsis and Septic Shock; Longitudinal Study
    Ince, Mehmet Ege
    Turgut, Kursad
    Naseri, Amir
    ANIMALS, 2021, 11 (07):
  • [49] Echocardiographic assessment of left ventricular systolic function
    Klaeboe, Lars Gunnar
    Edvardsen, Thor
    JOURNAL OF ECHOCARDIOGRAPHY, 2019, 17 (01) : 10 - 16
  • [50] The effect of ventricular pacing on measurements of left ventricular function: A comparison between echocardiographic methods and with radionuclide ventriculography
    Thackray, Simon D. R.
    Wright, Graham A.
    Witte, Klaus K. A.
    Nikitin, Nikolay P.
    Tweddel, Ann C.
    Clark, Andrew L.
    Cleland, John G. F.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (04): : 284 - 292