Variability in echocardiographic measurements of left ventricular function in septic shock patients

被引:35
|
作者
De Geer, Lina [1 ,2 ]
Oscarsson, Anna [1 ,2 ]
Engvall, Jan [2 ,3 ]
机构
[1] Linkoping Univ, Dept Intens Care, Linkoping, Sweden
[2] Linkoping Univ, Dept Med & Hlth Sci, Linkoping, Sweden
[3] Linkoping Univ, Dept Clin Physiol, Linkoping, Sweden
关键词
Echocardiography; Heart failure; Intensive care; Interobserver reliability; Repeatability; Shock; Septic; SEVERE SEPSIS; DIASTOLIC FUNCTION; DOPPLER-ECHOCARDIOGRAPHY; EJECTION FRACTION; SYSTOLIC FUNCTION; SPECKLE-TRACKING; FILLING PRESSURE; CRITICALLY-ILL; RECOMMENDATIONS; DYSFUNCTION;
D O I
10.1186/s12947-015-0015-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Echocardiography is increasingly used for haemodynamic evaluation and titration of therapy in intensive care, warranting reliable and reproducible measurements. The aim of this study was to evaluate the observer dependence of echocardiographic findings of left ventricular (LV) diastolic and systolic dysfunction in patients with septic shock. Methods: Echocardiograms performed in 47 adult patients admitted with septic shock to a general intensive care unit (ICU) were independently evaluated by one cardiologist and one intensivist for the following signs: decreased diastolic tissue velocity of the base of the LV septum (e), increased early mitral inflow (E) to e ratio (E/e), decreased LV ejection fraction (EF) and decreased LV global longitudinal peak strain (GLPS). Diastolic dysfunction was defined as e <8.0 cm/s and/or E/e >= 15 and systolic dysfunction as EF <50% and/or GLPS > -15%. Ten randomly selected examinations were re-analysed two months later. Pearson's r was used to test the correlation and Bland-Altman plots to assess the agreement between observers. Kappa statistics were used to test the consistency between readers and intraclass correlation coefficients (ICC) for inter- and intraobserver variability. Results: In 44 patients (94%), image quality was sufficient for echocardiographic measurements. The agreement between observers was moderate (k = 0.60 for e, k = 0.50 for E/e and k = 0.60 for EF) to good (k = 0.71 for GLPS). Pearson's r was 0.76 for e, 0.85 for E/e, 0.78 for EF and 0.84 for GLPS (p < 0.001 for all four). The ICC between observers for e was very good (0.85; 95% confidence interval (CI) 0.73-0.92), good for E/e (0.70; 95% CI 0.45 - 0.84), very good for EF (0.87; 95% CI 0.77 - 0.93), excellent for GLPS (0.91; 95% CI 0.74 - 0.95), and very good for all measures repeated by one of the observers. On Bland-Altman analysis, the mean differences and 95% limits of agreement for e, E/e, EF and GLPS were -0.01 (0.04 - 0.07), 2.0 (-14.2 - 18.1), 0.86 (-16 - 14.3) and 0.04 (-5.04 - 5.12), respectively. Conclusions: Moderate observer-related differences in assessing LV dysfunction were seen. GLPS is the least user dependent and most reproducible echocardiographic measurement of LV function in septic shock.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Variability in echocardiographic measurements of left ventricular function in septic shock patients
    Lina De Geer
    Anna Oscarsson
    Jan Engvall
    Cardiovascular Ultrasound, 13
  • [2] Prognostic impact of left ventricular diastolic function in patients with septic shock
    Céline Gonzalez
    Emmanuelle Begot
    François Dalmay
    Nicolas Pichon
    Bruno François
    Anne-Laure Fedou
    Catherine Chapellas
    Antoine Galy
    Claire Mancia
    Thomas Daix
    Philippe Vignon
    Annals of Intensive Care, 6
  • [3] Prognostic impact of left ventricular diastolic function in patients with septic shock
    Gonzalez, Celine
    Begot, Emmanuelle
    Dalmay, Francois
    Pichon, Nicolas
    Francois, Bruno
    Fedou, Anne-Laure
    Chapellas, Catherine
    Galy, Antoine
    Mancia, Claire
    Daix, Thomas
    Vignon, Philippe
    ANNALS OF INTENSIVE CARE, 2016, 6
  • [4] Left ventricular systolic and diastolic function in septic shock
    Poelaert, J
    Declerck, C
    Vogelaers, D
    Colardyn, F
    Visser, CA
    INTENSIVE CARE MEDICINE, 1997, 23 (05) : 553 - 560
  • [5] Left ventricular systolic and diastolic function in septic shock
    J. Poelaert
    C. Declerck
    D. Vogelaers
    F. Colardyn
    C. A. Visser
    Intensive Care Medicine, 1997, 23 : 553 - 560
  • [6] LEFT VENTRICULAR SYSTOLIC FUNCTION AND SYSTOLIC ASYNCHRONY IN PATIENTS WITH SEPTIC SHOCK AND NORMAL LEFT VENTRICULAR EJECTION FRACTION
    Weng, Li
    Liu, Yongtai
    Zhou, Jianfang
    Guo, Xiaoxiao
    Peng, Jinmin
    Hu, Xiaoyun
    Fang, Quan
    Zhu, Wenling
    Li, Huijuan
    Du, Bin
    Zhang, Shuyang
    SHOCK, 2013, 40 (03): : 175 - 181
  • [7] Evaluation of left ventricular systolic function revisited in septic shock
    Xavier Repessé
    Cyril Charron
    Antoine Vieillard-Baron
    Critical Care, 17
  • [8] Evaluation of left ventricular systolic function revisited in septic shock
    Repesse, Xavier
    Charron, Cyril
    Vieillard-Baron, Antoine
    CRITICAL CARE, 2013, 17 (04):
  • [9] Left ventricular systolic performance, function and contractility in patients with severe sepsis or septic shock
    Chejtman, D.
    Hita, A.
    Baratta, S.
    Pratesi, P.
    Bilbao, J.
    Fernandez, H.
    Bernardez, D.
    Turri, D.
    CIRCULATION, 2008, 118 (12) : E424 - E424
  • [10] Echocardiographic assessment of left ventricular systolic function in neonatal calves with naturally occurring sepsis or septic shock due to diarrhea
    Naseri, Amir
    Sen, Ismail
    Turgut, Kursad
    Guzelbektes, Hasan
    Constable, Peter D.