Comparison of Cytotechnologists' and Cytopathologists' ASCUS Rates Preimplementation and Postimplementation of the ThinPrep® Imaging System

被引:5
|
作者
Selvaggi, Suzanne M. [1 ]
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Dept Pathol & Lab Med, Madison, WI USA
关键词
ThinPrep (R) imaging system; Pap test screening; ASCUS rates; cytotechnologists; CYTOLOGY; IMPLEMENTATION;
D O I
10.1002/dc.23189
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BackgroundThe automated ThinPrep (R) Imaging System assists the cytotechnologists in the primary screening of ThinPrep (R) Pap Tests. This study compares the concordance of the cytotechnologists and cytopathologists in the interpretation of Pap Tests as Atypical Squamous Cells of Undetermined Significance (ASCUS) before and after implementation of the Imager in our laboratory. MethodsFrom January 1-December 31, 2011, 12,853 ThinPrep (R) Pap Tests were processed on a ThinPrep (R) 3000 Processor, stained by the Papanicolaou method and screened manually by the cytotechnologists. In 2012, 26,581 Pap Tests were processed on a ThinPrep (R) 3000 Processor, stained with the ThinPrep (R) Stain, screened on the Image Processor, and reviewed on a Review Scope by the cytotechnologists. All cases interpreted as ASCUS were sent to the cytopathologist for final review. ResultsOverall, 52% of the ASCUS Pap Tests were overcalled by the cytotechnologists on manual screening and 56% were overcalled by the cytotechnologists with use of the ThinPrep (R) Imaging System, as addressed by the cytopathologist as the final arbitrator. ConclusionIn this study, initial use of a new technology resulted in over interpretation of negative cases as ASCUS. Increased usage and familiarity with the System should lead to pre-Imager rates. Diagn. Cytopathol. 2015;43:105-107. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:105 / 107
页数:3
相关论文
共 23 条
  • [21] Increased rate of atypical squamous cells of undetermined significance and declining high-risk human papillomavirus rates following implementation of ThinPrep Imaging system (Imager)
    Ly, A.
    Beck, A. H.
    Kong, C. S.
    Pai, R. K.
    [J]. LABORATORY INVESTIGATION, 2008, 88 : 80A - 80A
  • [22] THE EFFECTIVENESS OF THE THINPREP IMAGING SYSTEM IN IDENTIFYING BIOPSY PROVEN HIGH GRADE GLANDULAR DISEASE: A COMPARISON OF SENSITIVITY, CELLULARITY AND MORPHOLOGIC FEATURES OBSERVED IN SPLIT SAMPLE COLLECTIONS
    Halford, J. Ross
    Perkins, G.
    Walker, K.
    Boost, T.
    [J]. ACTA CYTOLOGICA, 2010, 54 (03) : 481 - 481
  • [23] Comparison of prostate cancer detection rates between magnetic resonance imaging-targeted biopsy and transrectal ultrasound-guided biopsy according to Prostate Imaging Reporting and Data System in patients with PSA ≥4 ng/mL: a systematic review and meta-analysis
    Zhu, Kai
    Qin, Zhiqiang
    Xue, Jianxin
    Miao, Chenkui
    Tian, Ye
    Liu, Shouyong
    Zhu, Shenhao
    Gu, Qi
    Hou, Chao
    Xu, Aiming
    Yang, Jie
    Wang, Zengjun
    [J]. TRANSLATIONAL ANDROLOGY AND UROLOGY, 2019, 8 (06) : 741 - 753