Expression of p63 immunostaining in liquid-based cytology (BD SurePath) of breast fine-needle aspiration

被引:5
|
作者
Osugi, Masumi [1 ]
Kinoshita, Kosei [1 ]
Sugita, Atsuro [1 ]
Kito, Katsumi [1 ]
Maeda, Toshiharu [1 ]
机构
[1] Ehime Prefectural Cent Hosp, Dept Pathol, 83 Kasuga Cho, Matsuyama, Ehime 7900024, Japan
关键词
breast pitfall; fine-needle aspiration cytology; liquid-based cytology; myoepithelial cell; p63; immunocytochemistry; MYOEPITHELIAL CELLS; MARKER; LESIONS;
D O I
10.1002/dc.24041
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Methods We performed p63 immunostaining to detect myoepithelial cells on BD SurePath liquid-based cytology (LBC) slides and examined whether this improved the diagnostic accuracy in breast fine-needle aspiration cytology (FNAC). We examined the diagnostic accuracy using the LBC-p63 immunostaining slides of 298 lesions obtained from July 2010 to August 2016. Results Conclusion We defined the cutoff values for malignancy as follows: (1) the percentage of p63+ cluster was <30%, (2) the percentage of p63+ single cells in cell clusters was <3%, (3) the number of p63+ single cells in the background was <20 when the total number of the cell clusters was <100, or the number was <120 when the total number was >= 100. The malignant lesions showed significantly lower values than the benign lesions in the percentage of p63+ clusters, the percentage of p63+ single cells in the clusters, and the number of p63+ single cells in the background (P < .001). The diagnostic values obtained only by Papanicolaou staining vs the improved values with LBC-p63 immunostaining slides were as follows. Sensitivity, 88.3% to 99.0%; specificity, 89.1% to 99.0%; positive predictive value, 94.8% to 99.5%; negative predictive value, 77.4% to 97.8%; diagnostic accuracy, 88.6% to 99.0%, respectively. The diagnostic accuracy of breast FNAC was significantly improved by adding LBC-p63 immunostaining.
引用
收藏
页码:845 / 852
页数:8
相关论文
共 50 条
  • [21] Mediastinal hydatidosis: Fine needle aspiration and liquid-based cytology
    Muralidaran, C.
    Gupta, N.
    Behera, D.
    Rajwanshi, A.
    CYTOPATHOLOGY, 2017, 28 (06) : 558 - 559
  • [22] p63 Immunocytochemistry assists in the diagnosis of problematic breast lesions on fine needle aspiration cytology (FNA)
    Harton, AM
    Wang, HH
    Schnitt, SJ
    Jacobs, TW
    MODERN PATHOLOGY, 2003, 16 (01) : 68A - 68A
  • [23] p63 immunocytochemistry assists in the diagnosis of problematic breast lesions on fine needle aspiration cytology (FNA)
    Harton, AM
    Wang, HH
    Schnitt, SJ
    Jacobs, TW
    LABORATORY INVESTIGATION, 2003, 83 (01) : 68A - 68A
  • [24] Discomfort with fine-needle aspiration cytology of the breast
    Blennerhassett, M
    LANCET, 2001, 357 (9258): : 805 - 805
  • [25] FINE-NEEDLE ASPIRATION CYTOLOGY IN BREAST LUMPS
    MARCACCIO, MJ
    OBRIEN, SE
    CHEN, VSM
    CANADIAN JOURNAL OF SURGERY, 1986, 29 (06) : 405 - 407
  • [26] Comparison of liquid-based preparation and conventional smear of fine-needle aspiration cytology of lymph node
    Singh, Priya
    Rohilla, Manish
    Dey, Pranab
    JOURNAL OF CYTOLOGY, 2016, 33 (04) : 187 - 191
  • [27] The Role of Fine-needle Aspiration Performed with Liquid-based Cytology in the Surgical Management of Thyroid Lesions
    Ardito, Guglielmo
    Rossi, Esther Diana
    Revelli, Luca
    Moschella, Francesca
    Giustozzi, Erica
    Fadda, Guido
    Marzola, Maria Cristina
    Rubello, Domenico
    IN VIVO, 2010, 24 (03): : 333 - 337
  • [28] Primary pure squamous cell carcinoma of the breast diagnosed by fine-needle aspiration cytology:: A case study using liquid-based cytology
    Vera-Alvarez, J.
    Garcia-Prats, M. D.
    Marigil-Gomez, M.
    Abascal-Agorreta, M.
    Lopez-Lopez, J. I.
    Ramon-Cajal, J. M.
    DIAGNOSTIC CYTOPATHOLOGY, 2007, 35 (07) : 429 - 432
  • [29] Endobronchial ultrasound-guided fine-needle aspiration and liquid-based thin-layer cytology
    Wallace, W. A. H.
    Monaghan, H. M.
    Salter, D. M.
    Gibbons, M. A.
    Skwarski, K. M.
    JOURNAL OF CLINICAL PATHOLOGY, 2007, 60 (04) : 388 - 391
  • [30] Utility of manual liquid-based cytology and conventional smears in the evaluation of various fine-needle aspiration samples
    Arul, P.
    JOURNAL OF CYTOLOGY, 2016, 33 (04) : 177 - 181