Functionalized Magnetic Force Enhances Magnetic Nanoparticle Guidance: From Simulation to Crossing of the Blood-Brain Barrier In Vivo

被引:6
|
作者
Do, Ton Duc [1 ]
Ul Amin, Faiz [2 ]
Noh, Yeongil [3 ,4 ]
Kim, Myeong Ok [2 ]
Yoon, Jungwon [3 ,4 ]
机构
[1] Nazarbayev Univ, Sch Sci & Technol, Dept Robot & Mechatron, Astana Z05H0P9, Astana, Kazakhstan
[2] Gyeongsang Natl Univ, Dept Biol & Appl Life Sci, Jinju 660701, South Korea
[3] Gyeongsang Natl Univ, Sch Mech & Aerosp Engn, Jinju 660701, South Korea
[4] Gyeongsang Natl Univ, ReCAPT, Jinju 660701, South Korea
基金
新加坡国家研究基金会;
关键词
Blood-brain barrier (BBB); electromagnetic actuation system; in vivo experiment; mice; simulation; targeted drug delivery; FIELD;
D O I
10.1109/TMAG.2015.2513601
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent studies, we introduced the concept of functionalized magnetic force as a method to prevent nanoparticles from sticking to vessel walls caused by extensive simulation and in vitro experiments involving a Y-shaped channel. In this paper, we further investigated the effectiveness of the functionalized magnetic force with a realistic 3-D vessel through simulations. For the simulations, we considered a more realistic continuous injection of particles with different magnetic forces and frequencies. Based on the results from our simulation studies, we performed in vivo mice experiments to evaluate the effectiveness of using a functionalized magnetic force to aid magnetic nanoparticles (MNPs) in crossing the blood-brain barrier (BBB). To implement the functionalized magnetic force, we developed an electromagnetic actuator regulated by a programmable direct current power supply. Our results indicate that a functionalized magnetic field (FMF) can effectively prevent MNPs from sticking, and also guide them across the BBB. We used 770 nm fluorescent carboxyl MNPs in this paper. Following intravenous administration of MNPs into mice, we applied an external magnetic field to mediate transport of the MNPs across the BBB and into the brain. Furthermore, we evaluated the differential effects of FMFs (0.25, 0.5, and 1 Hz) and constant magnetic fields (CMFs) on the transport of MNPs across the BBB. Our results showed that an FMF is more effective than a CMF in the transport and uptake of MNPs across the BBB in mice. In particular, applying an FMF with a 3 A current and 0.5 Hz frequency mediated the greatest transport and uptake of MNPs across the BBB in mice.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Targeted Delivery of Magnetic Nanoparticle-Bound Azidothymidine 5′-Triphosphate Across the Blood-Brain Barrier.
    Saiyed, Z. M.
    Gandhi, N. H.
    Nair, M. N.
    JOURNAL OF NEUROIMMUNE PHARMACOLOGY, 2010, 5 : S53 - S53
  • [22] Nanoparticles enhance brain delivery of blood-brain barrier-impermeable probes for in vivo optical and magnetic resonance imaging
    Koffie, Robert M.
    Farrar, Christian T.
    Saidi, Laiq-Jan
    William, Christopher M.
    Hyman, Bradley T.
    Spires-Jones, Tara L.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (46) : 18837 - 18842
  • [23] Nanoparticle crossing of blood-brain barrier: a road to new therapeutic approaches to central nervous system diseases
    Cena, Valentin
    Jativa, Pablo
    NANOMEDICINE, 2018, 13 (13) : 1513 - 1516
  • [24] Validation of In Vivo Magnetic Resonance Imaging Blood-Brain Barrier Permeability Measurements by Comparison With Gold Standard Histology
    Hoffmann, Angelika
    Bredno, Joerg
    Wendland, Michael F.
    Derugin, Nikita
    Hom, Jason
    Schuster, Tibor
    Su, Hua
    Ohara, Peter T.
    Young, William L.
    Wintermark, Max
    STROKE, 2011, 42 (07) : 2054 - 2060
  • [25] Quantitative assessment of in vivo Focused Ultrasound induced Blood-Brain Barrier Opening using Magnetic Resonance Imaging
    Samiotaki, G.
    Vlachos, F.
    Choi, J. J.
    Tung, Y. S.
    Konofagou, E. E.
    2010 IEEE 36TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2010,
  • [26] Nanoparticle-based in vivo investigation on blood-brain barrier permeability following ischemia and reperfusion
    Yang, CS
    Chang, CH
    Tsai, PJ
    Chen, WY
    Tseng, FG
    Lo, LW
    ANALYTICAL CHEMISTRY, 2004, 76 (15) : 4465 - 4471
  • [27] Contrast-Enhanced In Vivo Magnetic Resonance Microscopy of the Mouse Brain Enabled by Noninvasive Opening of the Blood-Brain Barrier With Ultrasound
    Howles, Gabriel P.
    Bing, Kristin F.
    Qi, Yi
    Rosenzweig, Stephen J.
    Nightingale, Kathryn R.
    Johnson, G. Allan
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (04) : 995 - 1004
  • [28] Elucidating the Inability of Functionalized Nanoparticles to Cross the Blood-Brain Barrier and Target Specific Cells in Vivo
    Naidu, Priya S. R.
    Gavriel, Nikolas
    Gray, Chloe G. G.
    Bartlett, Carole A.
    Toomey, Lillian M.
    Kretzmann, Jessica A.
    Patalwala, Diana
    McGonigle, Terence
    Denham, Eleanor
    Hee, Charmaine
    Ho, Diwei
    Taylor, Nicolas L.
    Norret, Marck
    Smith, Nicole M.
    Dunlop, Sarah A.
    Iyer, K. Swaminathan
    Fitzgerald, Melinda
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (25) : 22085 - 22095
  • [29] Protein-functionalized nanoparticles derived from end-functional polymers and polymer prodrugs for crossing the blood-brain barrier
    Cox, Alysia
    Vinciguerra, Daniele
    Re, Francesca
    Dal Magro, Roberta
    Mura, Simona
    Masserini, Massimo
    Couvreur, Patrick
    Nicolas, Julien
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2019, 142 : 70 - 82
  • [30] DOES MAGNETIC-RESONANCE IMAGING COMPROMISE INTEGRITY OF THE BLOOD-BRAIN BARRIER
    PRESTON, E
    BUTLER, K
    HAAS, N
    NEUROSCIENCE LETTERS, 1989, 101 (01) : 46 - 50