Energy dissipation measurements in frequency-modulated scanning probe microscopy

被引:26
|
作者
Proksch, Roger [1 ]
Kalinin, Sergei V. [2 ]
机构
[1] Asylum Res, Santa Barbara, CA USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN USA
关键词
Crosstalk - Yttrium iron garnet - Frequency modulation - Energy dissipation - Iron alloys - Sodium chloride;
D O I
10.1088/0957-4484/21/45/455705
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Local dissipation measurements by scanning probe microscopy have attracted increasing interest as a method for probing energy losses and hysteretic phenomena due to magnetic, electrical, and structural transformations at the tip-surface junction. One challenge of this technique is the lack of a standard for ensuring quantification of the dissipation signal. In the following, we explored magnetic dissipation imaging of an yttrium-iron garnet (YIG) sample, using a number of similar but not identical cantilever probes. Typical frequency-dependent dispersion of the actuator-probe assembly commonly approached +/- 1 part in 10(3) Hz(-1), much larger than the minimum detectable level of +/- 1 part in 10(5) Hz(-1). This cantilever-dependent behavior results in a strong crosstalk between the conservative (frequency) and dissipative channels. This crosstalk was very apparent in the YIG dissipation images and in fact should be an inherent feature of single-frequency heterodyne detection schemes. It may also be a common effect in other dissipation imaging, even down to the atomic level, and in particular may be a significant issue when there are correlations between the conservative and dissipative components. On the other hand, we present a simple method for correcting for this effect. This correction technique resulted in self-consistent results for the YIG dissipation measurements and would presumably be effective for other systems as well.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] TENSOMETRIC FREQUENCY-MODULATED OSCILLATOR
    YURASOV, EP
    MEASUREMENT TECHNIQUES-USSR, 1970, (02): : 303 - &
  • [32] RESOLUTION OF A FREQUENCY-MODULATED REFLECTOMETER
    LEVIN, MM
    MEASUREMENT TECHNIQUES, 1972, 15 (08) : 1213 - 1214
  • [33] PITCH OF FREQUENCY-MODULATED SINUSOIDS
    MCCLELLAND, KD
    BRANDT, JF
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1969, 45 (06): : 1489 - +
  • [34] PITCH OF FREQUENCY-MODULATED SIGNALS
    RITSMA, RJ
    ENGEL, FL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1964, 36 (09): : 1637 - &
  • [35] Measurement techniques with frequency-modulated probe light for proximity and tactile combo sensor
    Umeki N.
    Nozawa A.
    Okuyama M.
    Noma H.
    Abe T.
    Sohgawa M.
    IEEJ Transactions on Sensors and Micromachines, 2017, 137 (05) : 146 - 150
  • [36] Low-frequency vibration measurements in harsh environments using a frequency-modulated interferometer
    Vu, Tung Thanh
    Hoang, Tu Anh
    Pham, Quang Duc
    AIP ADVANCES, 2024, 14 (05)
  • [37] Ultralow Dissipation Patterned Silicon Nanowire Arrays for Scanning Probe Microscopy
    Sahafi, Pardis
    Rose, William
    Jordan, Andrew
    Yager, Ben
    Pisciteli, Michele
    Budakian, Ram
    NANO LETTERS, 2020, 20 (01) : 218 - 223
  • [38] Frequency-modulated ratchet with autoresonance
    D. V. Makarov
    E. V. Sosedko
    M. Yu. Uleysky
    The European Physical Journal B, 2010, 73 : 571 - 579
  • [39] Numerical analysis of single-point spectroscopy curves used in photo-carrier dynamics measurements by Kelvin probe force microscopy under frequency-modulated excitation
    Garrillo, Pablo A. Fernandez
    Grevin, Benjamin
    Borowik, Lukasz
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2018, 9 : 1834 - 1843
  • [40] Noncontact microrheology at acoustic frequencies using frequency-modulated atomic force microscopy
    Gavara N.
    Chadwick R.S.
    Nature Methods, 2010, 7 (8) : 650 - 654