Pulsed current gradient power supply for microcoil magnetic resonance Imaging

被引:5
|
作者
Seeber, DA
Hoftiezer, JH
Pennington, CH
机构
[1] IGC Med Advances Inc, Milwaukee, WI 53226 USA
[2] Ohio State Univ, Dept Phys, Columbus, OH 43210 USA
来源
CONCEPTS IN MAGNETIC RESONANCE | 2002年 / 15卷 / 03期
关键词
microcoils; magnetic resonance imaging; gradient power supply;
D O I
10.1002/cmr.10038
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Magnetic resonance imaging (MRI) microscopy requires very strong gradients (>10 T/m) that can be rapidly switched between positive and negative gradient fields. A gradient power supply is presented that is capable of pulsing a custom built triaxial microcoil gradient system to an excess of 15 T/m (and as high as 50 T/m), representing pulsed currents in excess of 150 A into loads of similar to200 mOmega (gradient coil plus cables). The gradient power supply is switchable (from positive to negative gradient fields) within a time of similar to10 Vs. An H-bridge design, consisting of four metal-oxide semiconductor field-effect transistors (MOSFETs), is used for changing both the current and magnetic field gradient directions. In series with the H bridge is an additional MOSFET that is optimized to be a voltage-controlled (adjustable) resistor to send the current through the gradient coils. Because MOSFETS require special driving circuits to overcome parasitic capacitances, the MOSFET fundamental design parameters are also presented to complete the circuit schematics. The gradient power supply presented allows for the high gradient fields required for microcoil MRI of small samples. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:189 / 200
页数:12
相关论文
共 50 条
  • [1] Triaxial magnetic field gradient system for microcoil magnetic resonance imaging
    Seeber, DA
    Hoftiezer, JH
    Daniel, WB
    Rutgers, MA
    Pennington, CH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (11): : 4263 - 4272
  • [2] Resonant power supply for Magnetic Resonance Imaging gradient drivers
    Sabaté, J
    Schutten, M
    Li, QM
    Wirth, WF
    PESC'03: 2003 IEEE 34TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1815 - 1820
  • [3] Noise performance of a precision pulsed electromagnet power supply for magnetic resonance imaging
    Matter, Nathaniel I.
    Chronik, Blaine
    Pauly, John M.
    Macovski, Albert
    Conolly, Steven M.
    Scott, Greig C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (01) : 75 - 86
  • [4] Stripe Sensor Tomography and Application to Microcoil Magnetic Resonance Imaging
    Ibrahim, Fatima
    Barbie, Mladen
    Druzgalski, Christopher
    PAHCE: 2009 PAN AMERICAN HEALTH CARE EXCHANGES, 2009, : 143 - 143
  • [5] Planar microcoil-based magnetic resonance imaging of cells
    Massin, C
    Eroglu, S
    Vincent, F
    Gimi, BS
    Besse, PA
    Magin, RL
    Popovic, RS
    BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 967 - 970
  • [6] Power supply for pulsed magnets with magnetic energy recovery current switch
    Takaku, T
    Isobe, T
    Narushima, J
    Shimada, R
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 1794 - 1797
  • [7] Pulsed gradient spin echo nuclear magnetic resonance imaging of diffusion in granular flow
    Seymour, JD
    Caprihan, A
    Altobelli, SA
    Fukushima, E
    PHYSICAL REVIEW LETTERS, 2000, 84 (02) : 266 - 269
  • [8] In vitro detection of apoptosis using oscillating and pulsed gradient diffusion magnetic resonance imaging
    Portnoy, S.
    Fichtner, N. D.
    Dziegielewski, C.
    Stanisz, M. P.
    Stanisz, G. J.
    NMR IN BIOMEDICINE, 2014, 27 (04) : 371 - 380
  • [9] Resolution Improvement in a High-Power Magnetic Resonance Imaging Gradient Power Amplifier
    Zeng, Keqiu
    Popovic, Jelena
    Rietveld, Gert
    Mao, Saijun
    Yu, Hui
    Wang, Liguo
    Liu, Kun
    Zhou, Zhiding
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (09) : 10594 - 10608
  • [10] Microcoil nuclear magnetic resonance spectroscopy
    Webb, AG
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (05) : 892 - 903