Real-time implementation of ring based saturated core fault current limiter to improve fault ride through capability of DFIG system

被引:3
|
作者
Tripathi, Prashant Mani [1 ]
Chatterjee, Kalyan [1 ]
机构
[1] Indian Inst Technol ISM, Dept Elect Engn, Dhanbad, Jharkhand, India
关键词
Doubly fed induction generator (DFIG); Fault ride-through (FRT); Fault current limiter (FCL); Saturated core fault current limiter (SCFCL); FED INDUCTION GENERATOR; LOW-VOLTAGE RIDE; STABILITY ENHANCEMENT; POWER-SYSTEM;
D O I
10.1016/j.ijepes.2021.107040
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Enhancement of fault ride-through (FRT) capability in doubly-fed induction generator (DFIG) system is presented in this paper. The saturated core fault current limiter (SCFCL) works on the behaviour of magnetic field induction theory. It is composed of the ferromagnetic core with three limb construction, where both side limbs are surrounded with AC coil and middle limb with DC coil. For the application of restrictive fault, the ideal SCFCL can work for only low-power rating machines. But for the machine higher power rating, the ideal SCFCL has a drawback of developing heat across the limbs, which can damage the insulation of the coils. To overcome this glitch, the embedding of the copper ring across center limb and using forced-air cooling in SCFCL is used. This ring-based SCFCL (RSCFCL) is placed across the stator of DFIG system, which helps in minimizing fault current during any grid disturbances. Having low impedance during normal condition, it can be located permanently in the system without disturbing its stability. The feasibility of ideal SCFCL and RSCFCL is validated by studying the characteristics using thermal radiation under normal and fault conditions. The use of infrared imaging helps to monitor the thermographic patterns of the core on several conditions. The performance of RSCFCL is analyzed with the help of experimental setup and real-time simulator OPAL-RT 4510. Also, to check its effectiveness, it is used for FRT capability in the DFIG system application.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Controllable DC-link fault current limiter augmentation with DC chopper to improve fault ride-through of DFIG (vol 11, pg 313, 2016)
    Jalilian, Amin
    Naderi, Seyed Behzad
    Negnevitsky, Michael
    Hagh, Mehrdad Tarafdar
    Muttaqi, Kashem M.
    IET RENEWABLE POWER GENERATION, 2017, 11 (08) : 1304 - 1304
  • [32] A Dynamic Multi-Cell FCL to Improve the Fault Ride through Capability of DFIG-Based Wind Farms
    Shafiee, M. R.
    Kartijkolaie, H. Shahbabaei
    Firouzi, M.
    Mobayen, S.
    Fekih, A.
    ENERGIES, 2020, 13 (22)
  • [33] Improving Fault Ride-Through Capability of DFIG Connected Wind Turbine System: A Review
    Aga, Julekhabi M.
    Jadhav, H. T.
    2013 INTERNATIONAL CONFERENCE ON POWER, ENERGY AND CONTROL (ICPEC), 2013, : 613 - 618
  • [34] Fault Analysis of VSC-HVDC System with Saturated Iron-Core Superconductive Fault Current Limiter
    Li, Bo Tong
    Jia, Jian Fei
    Li, Bin
    Zhang, Yun Ke
    2015 IEEE INTERNATIONAL CONFERENCE ON APPLIED SUPERCONDUCTIVITY AND ELECTROMAGNETIC DEVICES (ASEMD), 2015, : 388 - 390
  • [35] A Novel Three Limb Topology of a Saturated Core Fault Current Limiter in HVBC System
    Zhou, H.
    Yuan, J.
    Wei, L.
    Gan, P.
    Chen, F.
    Zhong, Y.
    Tian, C.
    Chen, B.
    Gao, Y.
    Muramatsu, K.
    2018 IEEE INTERNATIONAL MAGNETIC CONFERENCE (INTERMAG), 2018,
  • [36] Fault-Ride Through Capability Enhancement of DFIG-Based Wind Turbines by SFCL
    Abdellatif, Walid S. E.
    Alaboudy, Ali H. Kasem
    Azmy, Ahmed M.
    2018 TWENTIETH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2018, : 1104 - 1109
  • [37] PHIL Experimentation on Fault Ride Through Behavior of Doubly Fed Induction Generator Based Wind System in the Presence of Fault Current Limiter
    Gururaj, M., V
    Padhy, Narayana Prasad
    2018 IEEMA ENGINEER INFINITE CONFERENCE (ETECHNXT), 2018,
  • [38] Enhancing Low-Voltage Ride-Through Capability and Smoothing Output Power of DFIG With a Superconducting Fault-Current Limiter-Magnetic Energy Storage System
    Guo, Wenyong
    Xiao, Liye
    Dai, Shaotao
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (02) : 277 - 295
  • [39] Application of superconducting fault current limiter to an offshore substation for low voltage ride through (LVRT) capability enhancement
    Moon, Won-Sik
    Huh, Jae-Sun
    Kim, Jin-Seok
    Jo, Ara
    Kim, Jae-Chul
    ICIC Express Letters, 2015, 9 (11): : 3135 - 3141
  • [40] Low-Voltage Ride through Capability Augmentation of DFIG-Based Wind Farms Using Series-Parallel Resonance-Type Fault Current Limiter
    Ul Haque, Md. Yah-Ya
    Hasan, Jakir
    Islam, Md. Rashidul
    Islam, Md. Rabiul
    WIND, 2021, 1 (01): : 20 - 43