Assessment of Breathing Parameters Using an Inertial Measurement Unit (IMU)-Based System

被引:45
|
作者
Cesareo, Ambra [1 ]
Previtali, Ylenia [1 ]
Biffi, Emilia [2 ]
Aliverti, Andrea [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
[2] IRCCS E Medea, Bioengn Lab, Inst Sci, I-23842 Bosisio Parini, Lecco, Italy
关键词
principal component analysis; biomedical signal processing; wearable biomedical sensors; wireless sensor network; respiratory monitoring; optoelectronic plethysmography; FALSE DISCOVERY RATE; OPTOELECTRONIC PLETHYSMOGRAPHY; RESPIRATORY RATE; CHEST-WALL; RIB CAGE; ACCELEROMETER; VOLUME; VARIABLES;
D O I
10.3390/s19010088
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Breathing frequency (f(B)) is an important vital sign that-if appropriately monitored-may help to predict clinical adverse events. Inertial sensors open the door to the development of low-cost, wearable, and easy-to-use breathing-monitoring systems. The present paper proposes a new posture-independent processing algorithm for breath-by-breath extraction of breathing temporal parameters from chest-wall inclination change signals measured using inertial measurement units. An important step of the processing algorithm is dimension reduction (DR) that allows the extraction of a single respiratory signal starting from 4-component quaternion data. Three different DR methods are proposed and compared in terms of accuracy of breathing temporal parameter estimation, in a group of healthy subjects, considering different breathing patterns and different postures; optoelectronic plethysmography was used as reference system. In this study, we found that the method based on PCA-fusion of the four quaternion components provided the best f(B) estimation performance in terms of mean absolute errors (<2 breaths/min), correlation (r > 0.963) and Bland-Altman Analysis, outperforming the other two methods, based on the selection of a single quaternion component, identified on the basis of spectral analysis; particularly, in supine position, results provided by PCA-based method were even better than those obtained with the ideal quaternion component, determined a posteriori as the one providing the minimum estimation error. The proposed algorithm and system were able to successfully reconstruct the respiration-induced movement, and to accurately determine the respiratory rate in an automatic, position-independent manner.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Convolutional Neural Network for Driving Maneuver Identification Based on Inertial Measurement Unit (IMU) and Global Positioning System (GPS)
    Ahmed, Mobyen Uddin
    Begum, Shahina
    FRONTIERS IN SUSTAINABLE CITIES, 2020, 2
  • [22] A Position Tracking Experiment of Mobile Robot with Inertial Measurement Unit (IMU)
    Wongwirat, Olarn
    Chaiyarat, Chutchai
    INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2010), 2010, : 304 - 308
  • [23] Honeywell gun-hard inertial measurement unit (IMU) development
    Karnick, D
    Ballas, G
    Koland, L
    Secord, M
    Braman, T
    PLANS 2004: POSITION LOCATION AND NAVIGATION SYMPOSIUM, 2004, : 49 - 55
  • [24] Honeywell Gun-hard Inertial Measurement Unit (IMU) Development
    Karnick, Drew
    Troske, Terry
    Secord, Mike
    Hanson, Tim
    Braman, Todd
    MacGugan, Doug
    Kourepenis, Tony
    PROCEEDINGS OF THE 2007 NATIONAL TECHNICAL MEETING OF THE INSTITUTE OF NAVIGATION - NTM 2007, 2007, : 718 - 724
  • [25] High-precision inertial measurement unit IMU-5000
    Korkishko, Yu. N.
    Fedorov, V. A.
    Prilutskiy, V. E.
    Ponomarev, V. G.
    Fedorov, I. V.
    Kostritskii, S. M.
    Morev, I. V.
    Obuhovich, D. V.
    Prilutskiy, S. V.
    Zuev, A. I.
    Varnakov, V. K.
    2018 5TH IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS & SYSTEMS (INERTIAL 2018), 2018, : 33 - 36
  • [26] Fabricated Components Hoisting Activity Recognition and Collision Analysis Based on Inertial Measurement Unit IMU
    Wang, Chen
    Yu, Liangcheng
    Kassem, Mukhtar A.
    Yap, Jeffrey Boon Hui
    Wang, Mengyi
    Ali, Kherun Nita
    BUILDINGS, 2022, 12 (07)
  • [27] A Foot-Mounted Inertial Measurement Unit (IMU) Positioning Algorithm Based on Magnetic Constraint
    Wang, Yan
    Li, Xin
    Zou, Jiaheng
    SENSORS, 2018, 18 (03):
  • [28] Quantitative Assessment of Parkinsonian Tremor Based on an Inertial Measurement Unit
    Dai, Houde
    Zhang, Pengyue
    Lueth, Tim C.
    SENSORS, 2015, 15 (10) : 25055 - 25071
  • [29] Quantitative assessment of parkinsonian bradykinesia based on an inertial measurement unit
    Dai, Houde
    Lin, Haijun
    Lueth, Tim C.
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [30] Quantitative assessment of parkinsonian bradykinesia based on an inertial measurement unit
    Houde Dai
    Haijun Lin
    Tim C Lueth
    BioMedical Engineering OnLine, 14