Calibration of special relative humidity and temperature (RHT) sensors and evaluation and expression of uncertainty in the measurement

被引:0
|
作者
Singh, Bhikham [1 ]
Kishan, Hari [1 ]
Singh, Y. P. [1 ]
机构
[1] CSIR, Natl Phys Lab NPLI, New Delhi 110012, India
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reports the calibration of special type of relative humidity and temperature sensor, which gives the output in terms Of millivolts, measured by precision digital multimeter (DMM) to further estimation of relative humidity in,the range of 25 %RH to 95 %RH. The sensor has been calibrated against the standard aspirated psychrometer having a pair of matched dry and wet bulb quartz thermometers. The temperature of wet bulb thermometer is effectively depressed when a ventilated airflow is maintained at a speed more than 3 metre/second. The relative humidity of reference standard psychrometer is computed using psychrometric equation to relate with the output of the RH indicator under comparison. The paper also describes the details of estimation and expression of expanded uncertainty in the calibration of the sensor at measured relative humidity. A sufficient number of data were undertaken to evaluate the uncertainty at a confidence-level of approximately 95% for a normal probability distribution.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 50 条
  • [21] Calibration and validation processes for relative humidity measurement by a Hygrochron iButton
    Shin, Mirim
    Patton, Raymond
    Mahar, Trevor
    Ireland, Angus
    Swan, Paul
    Chow, Chin Moi
    PHYSIOLOGY & BEHAVIOR, 2017, 179 : 208 - 212
  • [22] Measurement uncertainty of piezoresistive beam-type humidity sensors
    Hoa, PLP
    Suchaneck, G
    Gerlach, G
    26TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY, CONFERENCE PROCEEDINGS: INTEGRATED MANAGEMENT OF ELECTRONIC MATERIALS PRODUCTION, 2003, : 408 - 411
  • [23] Integrated CMOS dew point sensors for relative humidity measurement
    Savalli, N
    Baglio, S
    Castorina, S
    Sacco, V
    Tringali, C
    SMART STRUCTURES AND MATERIALS 2004: SMART ELECTRONICS, MEMS, BIOMEMS AND NANOTECHNOLOGY, 2004, 5389 : 422 - 430
  • [24] Transistor temperature measurement for calibration of integrated temperature sensors
    Pertijs, MAP
    Huijsing, JH
    IMTC 2002: PROCEEDINGS OF THE 19TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 & 2, 2002, : 755 - 758
  • [25] Uncertainty of a calibration device for heat flux sensors - Uncertainty of the temperature difference
    Beerel, Joseph
    Bartz, Frederik
    Froehlich, Thomas
    TM-TECHNISCHES MESSEN, 2024, 91 (7-8) : 406 - 415
  • [26] Uncertainty of the Calibration of Paired Temperature Sensors for Heat Meters
    Erich Tegeler
    Dieter Heyer
    Bernd. R. L. Siebert
    International Journal of Thermophysics, 2008, 29 : 1174 - 1183
  • [27] Uncertainty of the calibration of paired temperature sensors for heat meters
    Tegeler, Erich
    Heyer, Dieter
    Siebert, Bernd. R. L.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (03) : 1174 - 1183
  • [28] Evaluation of Humidity Sensor Calibration Uncertainty by Monte Carlo Method
    Wei, M.
    Wen, C.
    Li, C.
    Miao, J.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2024, 39 (03): : 625 - 635
  • [29] Calibration of contact sensors for surface temperature measurement
    Bernhard, F
    Augustin, S
    Mammen, H
    Sommer, KD
    Tegeler, E
    Wagner, M
    Demisch, U
    Trageser, P
    TEMPERATURE '98, 1998, 1379 : 99 - 106
  • [30] Calibration of contact sensors for surface temperature measurement
    Reindl, L
    Scholl, G
    Ostertag, T
    Seisenberger, C
    Hornsteiner, J
    Pohl, A
    TEMPERATURE '98, 1998, 1379 : 93 - 98