Automatic detection of stent struts with thick neointimal growth in intravascular optical coherence tomography image sequences

被引:25
|
作者
Xu, Chenyang [1 ]
Schmitt, Joseph M. [1 ]
Akasaka, Takashi [2 ]
Kubo, Takashi [2 ]
Huang, Kun [3 ]
机构
[1] Lightlab Imaging Inc, Westford, MA 01886 USA
[2] Wakayama Med Univ, Dept Cardiovasc Med, Wakayama, Japan
[3] Ohio State Univ, Dept Biomed Informat, Columbus, OH 43210 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 20期
基金
日本学术振兴会;
关键词
BALLOON ANGIOPLASTY; PLACEMENT;
D O I
10.1088/0031-9155/56/20/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To assist cardiologists investigating neointimal tissue growth on stents during follow-up with optical coherence tomography (OCT), we developed an automatic algorithm to locate deeply buried stent struts and to quantify the restenosis burden. The technique is based on an improved steerable filter for computing the local ridge strength and orientation. It also uses an ellipsoid fitting algorithm and continuity criteria to obtain globally optimal stent localization. The restenosis burden calculations were compared to manual assessment of OCT coronary artery image data obtained from in vivo human clinical studies. Compared to manual assessment by expert readers, the algorithm operated with > 97% accuracy in the measurement of mean and maximum restenosis burden. The results indicated that the technique yielded comparable accuracy in measuring restenosis burden, and significantly reduced user interaction time.
引用
收藏
页码:6665 / 6675
页数:11
相关论文
共 50 条
  • [41] Optical Coherence Tomography Assessment of Neointimal Coverage According to the Presence Or Absence Of Malapposed Struts After Drug-eluting Stent Implantation
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B184 - B184
  • [42] Automatic fibroatheroma identification in intravascular optical coherence tomography volumes
    Qifeng Yan
    Mengdi Xu
    Damon Wing Kee Wong
    Akira Taruya
    Atsushi Tanaka
    Jiang Liu
    Philip Wong
    Jun Cheng
    [J]. Journal of Ambient Intelligence and Humanized Computing, 2023, 14 : 15477 - 15483
  • [43] Automatic fibroatheroma identification in intravascular optical coherence tomography volumes
    Yan, Qifeng
    Xu, Mengdi
    Wong, Damon Wing Kee
    Taruya, Akira
    Tanaka, Atsushi
    Liu, Jiang
    Wong, Philip
    Cheng, Jun
    [J]. JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2019, 14 (11) : 15477 - 15483
  • [44] Automatic Volume Classification in Intravascular Optical Coherence Tomography Images
    Xu, Mengdi
    Cheng, Jun
    Lee, Jimmy Addison
    Wong, Damon Wing Kee
    Taruya, Akira
    Tanaka, Atsushi
    Foin, Nicolas
    Wong, Philip
    [J]. 2017 IEEE 2ND INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING (ICSIP), 2017, : 198 - 202
  • [45] Accuracy of Optical Coherence Tomography in the Evaluation of Neointimal Coverage After Stent Implantation
    Murata, Akira
    Wallace-Bradley, David
    Tellez, Armando
    Alviar, Carlos
    Aboodi, Michael
    Sheehy, Alexander
    Coleman, Leslie
    Perkins, Laura
    Nakazawa, Gaku
    Mintz, Gary
    Kaluza, Greg L.
    Virmani, Renu
    Granada, Juan F.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2010, 3 (01) : 76 - 84
  • [46] Approaches to segment stent area from intravascular optical coherence tomography
    Gaiarsa V.M.
    Cardenas D.
    Furuie S.S.
    [J]. Gaiarsa, Veronica Meyer (vmgaiarsa@gmail.com), 1600, Brazilian Society of Biomedical Engineering (33): : 11 - 20
  • [47] Automated measurement of stent strut coverage in intravascular optical coherence tomography
    Chi Young Ahn
    Byeong-Keuk Kim
    Myeong-Ki Hong
    Yangsoo Jang
    Jung Heo
    Chulmin Joo
    Jin Keun Seo
    [J]. Journal of the Korean Physical Society, 2015, 66 : 558 - 570
  • [48] Optical coherence tomography or intravascular ultrasound to optimize coronary stent implantation
    Alfonso, Fernando
    Prati, Francesco
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 (42) : 3148 - 3151
  • [49] Automated Measurement of Stent Strut Coverage in Intravascular Optical Coherence Tomography
    Ahn, Chi Young
    Kim, Byeong-Keuk
    Hong, Myeong-Ki
    Jang, Yangsoo
    Heo, Jung
    Joo, Chulmin
    Seo, Jin Keun
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (04) : 558 - 570
  • [50] Optical coherence tomography compared to intravascular ultrasound for detecting small degrees of neointimal hyperplasia
    Ikeno, F.
    Koizumi, T.
    Yeung, A. C.
    Fitzgerald, P. J.
    Fearon, W. F.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 580 - 580