Shear wave velocity of the healthy thyroid gland in children with acoustic radiation force impulse elastography

被引:13
|
作者
Bilgici, Meltem Ceyhan [1 ]
Saglam, Dilek [1 ]
Delibalta, Semra [1 ]
Yucel, Serap [1 ]
Tomak, Leman [2 ]
Elmali, Muzaffer [1 ]
机构
[1] Ondokuz Mayis Univ, Sch Med, Dept Radiol, TR-55270 Atakum, Samsun, Turkey
[2] Ondokuz Mayis Univ, Sch Med, Dept Biostat, TR-55270 Atakum, Samsun, Turkey
关键词
Acoustic radiation force impulse elastography; Children; Thyroid gland; Ultrasonography; DIFFERENTIAL-DIAGNOSIS; BENIGN; NODULES;
D O I
10.1007/s10396-017-0788-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Acoustic radiation force impulse imaging is a kind of shear wave elastography that can be used in children for differentiating thyroid pathologies. Possible changes in the healthy thyroid gland in children may create difficulties in the use of shear wave velocities (SWV) in thyroid pathologies. The aim of this study was to define the normal values of SWV for the healthy thyroid gland in children, elucidate the correlation of the SWV values with potential influencing factors, and evaluate intra-operator reproducibility of the SWV. Between January 2015 and December 2015, a total of 145 healthy children (81 girls, 64 boys; mean age, 10.5 +/- 3.14 years; range 6-17 years) were enrolled in the study. The SWV and volume of the thyroid gland were determined. The mean shear wave velocity of the thyroid gland was 1.22 +/- 0.20 m/s. There was no correlation between age and the mean SWV of the thyroid gland (Spearman Rho = 0.049, p = 0.556). There was also no correlation between the thyroid gland volume or BSA and the mean SWV. The only correlation detected was between BSA and total thyroid gland volume (p < 0.001). In the present study, the SWV of the healthy thyroid gland in children was determined. There was no correlation between the SWV of the thyroid gland and age, BSA, or thyroid gland volume.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 50 条
  • [41] Acoustic radiation force impulse imaging elastography is efficacious in detecting hepatic fibrosis in children
    Pico Aliaga, S. D.
    Muro Velilla, D.
    Garcia-Marti, G.
    Sanguesa Nebot, C.
    Marti-Bonmati, L.
    RADIOLOGIA, 2015, 57 (04): : 314 - 320
  • [42] Acoustic radiation force impulse (ARFI) elastography for the noninvasive diagnosis of liver fibrosis in children
    Hanquinet, Sylviane
    Rougemont, Anne-Laure
    Courvoisier, Delphine
    Rubbia-Brandt, Laura
    Mclin, Valerie
    Tempia, Michela
    Anooshiravani, Mehrak
    PEDIATRIC RADIOLOGY, 2013, 43 (05) : 545 - 551
  • [43] Acoustic radiation force impulse (ARFI) elastography for the noninvasive diagnosis of liver fibrosis in children
    Sylviane Hanquinet
    Anne‐Laure Rougemont
    Delphine Courvoisier
    Laura Rubbia-Brandt
    Valérie Mclin
    Michela Tempia
    Mehrak Anooshiravani
    Pediatric Radiology, 2013, 43 : 545 - 551
  • [44] Acoustic radiation force impulse (ARFI) elastography of kidneys in healthy adult cats: preliminary results
    Garcia, P. H. S.
    Feliciano, M. A. R.
    Carvalho, C. F.
    Crivellenti, L. Z.
    Maronezi, M. C.
    Almeida, V. T.
    Uscategui, R. R.
    Vicente, W. R. R.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2015, 56 (08) : 505 - 509
  • [45] Acoustic radiation force impulse (ARFI) elastography of the spleen in healthy adult cats - a preliminary study
    Feliciano, M. A. R.
    Maronezi, M. C.
    Crivellenti, L. Z.
    Crivellenti, S. B.
    Simoes, A. P. R.
    Brito, M. B. S.
    Garcia, P. H. S.
    Vicente, W. R. R.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2015, 56 (03) : 180 - 183
  • [46] Comparative study between two point Shear Wave Elastographic techniques: Acoustic Radiation Force Impulse (ARFI) elastography and ElastPQ
    Sporea, Ioan
    Bota, Simona
    Gradinaru-Tascau, Oana
    Sirli, Roxana
    Popescu, Alina
    MEDICAL ULTRASONOGRAPHY, 2014, 16 (04) : 309 - 314
  • [47] FACTORS THAT INFLUENCE KIDNEY SHEAR WAVE SPEED ASSESSED BY ACOUSTIC RADIATION FORCE IMPULSE ELASTOGRAPHY IN PATIENTS WITHOUT KIDNEY PATHOLOGY
    Bota, Simona
    Bob, Flaviu
    Sporea, Ioan
    Sirli, Roxana
    Popescu, Alina
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (01): : 1 - 6
  • [48] NON-INVASIVE EVALUATION OF LIVER FIBROSIS: 2-D SHEAR WAVE ELASTOGRAPHY, TRANSIENT ELASTOGRAPHY OR ACOUSTIC RADIATION FORCE IMPULSE IMAGING?
    Ozturker, Coskun
    Karagoz, Ergenekon
    Incedayi, Mehmet
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (12): : 3052 - 3052
  • [49] IS ACOUSTIC RADIATION FORCE IMPULSE ELASTOGRAPHY (ARFI) A REPRODUCIBLE METHOD?
    Bota, S.
    Sporea, I.
    Sirli, R.
    Popescu, A.
    Danila, M.
    Sendroiu, M.
    JOURNAL OF HEPATOLOGY, 2011, 54 : S129 - S129
  • [50] Evaluation of Acoustic Radiation Force Impulse Elastography for Liver Tumors
    Chiba, Mitsuru
    Goto, Takashi
    Miura, Kouichi
    Ohshima, Shigetoshi
    Shibuya, Tomomi
    Sato, Wataru
    Dohmen, Takahiro
    Yamada, Ikuhiro
    Kamada, Kentaro
    Kanata, Ryo
    Sakai, Toshitaka
    Sugimoto, Yuko
    Ohnishi, Hirohide
    GASTROENTEROLOGY, 2012, 142 (05) : S1004 - S1004