ECF (electro-conjugate fluid) finger with bidirectional motion and its application to a flexible hand

被引:27
|
作者
Nagaoka, Tomonobu [1 ]
Mao, Zebing [2 ]
Takemura, Kenjiro [3 ]
Yokota, Shinichi [4 ]
Kim, Joon-Wan [4 ]
机构
[1] Tokyo Inst Technol, Interdisciplinary Grad Sch Sci & Engn, Dept Mechanomicro Engn, Tokyo, Japan
[2] Tokyo Inst Technol, Sch Engn, Dept Mech Engn, Tokyo, Japan
[3] Keio Univ, Dept Mech Engn, Tokyo, Japan
[4] Tokyo Inst Technol, IIR, Lab Future Interdisciplinary Res Sci & Technol FI, Midori Ku, J3-12,4259 Nagatsuta Cho, Yokohama, Kanagawa 2258503, Japan
基金
日本学术振兴会;
关键词
electro-conjugated fluid (ECF); microfinger; bidirectional motion; flexible microhand; ROBOT HAND;
D O I
10.1088/1361-665X/aaf49a
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we propose and develop an electro-conjugate fluid (ECF) finger with bidirectional motion and its application to a flexible hand. The finger is composed of a finger tube (5 mm in diameter) and a unit of ECF jet generators (5 x 7 x 8 mm(3)). The ECF is a kind of functional and dielectric fluid. Its jet flow is generated between two electrodes surrounded by the ECF under the high DC voltage. The ECF jet generator can be utilized as a hydraulic pressure source for the flexible finger tube and embedded in the finger. The flexible finger tube consists of two silicone rubber chambers whose cross-section is the shape of semi-circle along its axis. In the unit, there are two ECF jet generators, each of which has two pairs of needle-ring electrodes in parallel and which are connected to each other through the common line and placed to the opposite direction for the bidirectional motion of the ECF finger. One chamber of the finger expands due to the inner pressure generated by the ECF jet and the other one as an ECF container shrinks, causing the ECF finger to bend. The suitable parameters of the flexible finger tube are obtained by optimizing the cross-sectional shapes, the thickness of the partition and the fiber interval of the finger tube. Besides, the characteristics of the ECF finger including the displacement and self-generating force are investigated by experiments. The experimental results indicate that the proposed ECF finger can realize bidirectional motions with 9.2 mm in left-displacement and 6.4 mm in right-displacement and generate the maximum force: 6.6 mN. The final application of the ECF finger to a flexible hand also clearly shows the fingers are capable of grasping and releasing the object.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] DP-RE type micromotors using electro-conjugate fluid
    Yokota, Shinichi
    Kozuki, Hiroto
    Takemura, Kenjiro
    Edamura, Kazuya
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-10, 2007, : 1566 - +
  • [42] An SMA-driven micropump using electro-conjugate fluid jet cooling
    Yokota, S
    Yoshida, K
    Kawaue, T
    Otsubo, Y
    Edamura, K
    MECHATRONICS '98, 1998, : 453 - 458
  • [43] A microfluidic device integrated with a stretchable microporous membrane controlled by electro-conjugate fluid
    Otomo, Taiki
    Matsubara, Tatsuya
    Yoshida, Kazuhiro
    Kim, Deok-Ho
    Ikeuchi, Masashi
    Kim, Joon-wan
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 356
  • [44] Development and control of a micro artificial muscle cell using electro-conjugate fluid
    Takemura, Kenjiro
    Yokota, Shinichi
    Edamura, Kazuya
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 133 (02) : 493 - 499
  • [45] Design, fabrication and experimental investigation of a planar pump using electro-conjugate fluid
    Seo, Woo-Suk
    Yang, Soon-Young
    Lee, Byung-Ryong
    Ahn, Kyoung-Kwan
    Ham, Young-Bog
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2007, 21 (08) : 1320 - 1327
  • [46] Micro Actuators by Making Use of Jet Flows Due to Electro-Conjugate Fluid
    Yokota, Shinichi
    MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2008, 36 (04) : 330 - 345
  • [47] Design, fabrication and experimental investigation of a planar pump using electro-conjugate fluid
    Woo-Suk Seo
    Soon-Young Yang
    Byung-Ryong Lee
    Kyoung-Kwan Ahn
    Young-Bog Ham
    Journal of Mechanical Science and Technology, 2007, 21 : 1320 - 1327
  • [48] Numerical simulation of electro-conjugate fluid flow considering electric double layer
    Iijima, Yoshiki
    Hosoda, Kyohei
    Takemura, Kenjiro
    Fukagata, Koji
    Edamura, Kazuya
    MECHANICAL ENGINEERING JOURNAL, 2015, 2 (06):
  • [49] Active microvalve driven by electro-conjugate fluid jet flow with a hydraulic power source on a chip
    Matsubara T.
    Yoshida K.
    Kim J.-W.
    Journal of Micromechanics and Microengineering, 2020, 30 (10)
  • [50] A high performance planar pump using electro-conjugate fluid with improved electrode patterns
    Seo, Woo-Suk
    Yoshida, Kazuhiro
    Yokota, Shinichi
    Edamura, Kazuya
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 134 (02) : 606 - 614