ECF (electro-conjugate fluid) finger with bidirectional motion and its application to a flexible hand

被引:27
|
作者
Nagaoka, Tomonobu [1 ]
Mao, Zebing [2 ]
Takemura, Kenjiro [3 ]
Yokota, Shinichi [4 ]
Kim, Joon-Wan [4 ]
机构
[1] Tokyo Inst Technol, Interdisciplinary Grad Sch Sci & Engn, Dept Mechanomicro Engn, Tokyo, Japan
[2] Tokyo Inst Technol, Sch Engn, Dept Mech Engn, Tokyo, Japan
[3] Keio Univ, Dept Mech Engn, Tokyo, Japan
[4] Tokyo Inst Technol, IIR, Lab Future Interdisciplinary Res Sci & Technol FI, Midori Ku, J3-12,4259 Nagatsuta Cho, Yokohama, Kanagawa 2258503, Japan
基金
日本学术振兴会;
关键词
electro-conjugated fluid (ECF); microfinger; bidirectional motion; flexible microhand; ROBOT HAND;
D O I
10.1088/1361-665X/aaf49a
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we propose and develop an electro-conjugate fluid (ECF) finger with bidirectional motion and its application to a flexible hand. The finger is composed of a finger tube (5 mm in diameter) and a unit of ECF jet generators (5 x 7 x 8 mm(3)). The ECF is a kind of functional and dielectric fluid. Its jet flow is generated between two electrodes surrounded by the ECF under the high DC voltage. The ECF jet generator can be utilized as a hydraulic pressure source for the flexible finger tube and embedded in the finger. The flexible finger tube consists of two silicone rubber chambers whose cross-section is the shape of semi-circle along its axis. In the unit, there are two ECF jet generators, each of which has two pairs of needle-ring electrodes in parallel and which are connected to each other through the common line and placed to the opposite direction for the bidirectional motion of the ECF finger. One chamber of the finger expands due to the inner pressure generated by the ECF jet and the other one as an ECF container shrinks, causing the ECF finger to bend. The suitable parameters of the flexible finger tube are obtained by optimizing the cross-sectional shapes, the thickness of the partition and the fiber interval of the finger tube. Besides, the characteristics of the ECF finger including the displacement and self-generating force are investigated by experiments. The experimental results indicate that the proposed ECF finger can realize bidirectional motions with 9.2 mm in left-displacement and 6.4 mm in right-displacement and generate the maximum force: 6.6 mN. The final application of the ECF finger to a flexible hand also clearly shows the fingers are capable of grasping and releasing the object.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Development of MEMS-fabricated bidirectional ECF (electro-conjugate fluid) micropumps
    Matsubara, Tatsuya
    Huy Hoang Huynh
    Yoshida, Kazuhiro
    Kim, Joon-wan
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 295 : 317 - 323
  • [2] Robot Finger Using Electro-Conjugate Fluid
    Yamaguchi, Akihiro
    Takemura, Kenjiro
    Yokota, Shinichi
    Edamura, Kazuya
    ADVANCED ROBOTICS, 2012, 26 (8-9) : 861 - 876
  • [3] A Robot Hand Using Electro-conjugate Fluid
    Yamaguchi, Akihiro
    Takemura, Kenjiro
    Yokota, Shinichi
    Edamura, Kazuya
    2011 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2011,
  • [4] A robot hand using electro-conjugate fluid
    Yamaguchi, Akihiro
    Takemura, Kenjiro
    Yokota, Shinichi
    Edamura, Kazuya
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 170 (1-2) : 139 - 146
  • [5] High-Integration Micromotor Using Electro-Conjugate Fluid (ECF)
    Yokota, Shinichi
    Kawamura, Kiyomi
    Takemura, Kenjiro
    Edamura, Kazuya
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2005, 17 (02) : 142 - 148
  • [6] Active sorting of droplets by using an ECF (Electro-conjugate Fluid) micropump
    Mao, Zebing
    Yoshida, Kazuhiro
    Kim, Joon-wan
    SENSORS AND ACTUATORS A-PHYSICAL, 2020, 303
  • [7] Comprehending electro-conjugate fluid (ECF) jets by using the Onsager effect
    Kim, Joon-wan
    Tanabe, Yusuke
    Yokota, Shinichi
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 295 : 266 - 273
  • [8] Control of a novel flexible finger using electro-conjugate fluid with built-in angle sensor
    Mori, Kento
    Yamaguchi, Akihiro
    Takemura, Kenjiro
    Yokota, Shinichi
    Edamura, Kazuya
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 183 : 75 - 83
  • [9] Soft fiber-reinforced bending finger with three chambers actuated by ECF (electro-conjugate fluid) pumps
    Mao, Zebing
    Nagaoka, Tomonobu
    Yokota, Shinichi
    Kim, Joon-wan
    SENSORS AND ACTUATORS A-PHYSICAL, 2020, 310
  • [10] A droplet-generator-on-a-chip actuated by ECF (electro-conjugate fluid) micropumps
    Zebing Mao
    Kazuhiro Yoshida
    Joon-wan Kim
    Microfluidics and Nanofluidics, 2019, 23