Metasurface enabled on-chip double-beam scheme for SERF atomic magnetometer

被引:16
|
作者
Liang, Zihua [1 ,2 ]
Zhou, Binquan [2 ,3 ]
Lu, Jixi [2 ,3 ]
Liu, Ying [2 ,3 ]
Hu, Jinsheng [1 ,2 ]
Zhou, Peng [1 ,2 ]
Wang, Weiyi [2 ,3 ]
Liu, Lu [2 ,3 ]
Hu, Gen [2 ,3 ]
Ye, Mao [2 ,3 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[2] Beihang Hangzhou Innovat Inst Yuhang, Hangzhou 310023, Peoples R China
[3] Beihang Univ, Res Inst Frontier Sci, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
SERF atomic magnetometer; Metasurface; Double beam scheme; Biomagnetism measurement; METALENS;
D O I
10.1016/j.optcom.2022.128850
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Double-beam atomic magnetometer (AM) working in spin-exchange relaxation-free (SERF) regime is drawing growing attention due to high sensitivity (femtotesla-level) and non-intrusion characteristics. Nowadays, chip integration of AMs in pursuit of dramatical reduction in volume has become a major trend as it is especially favorable for future high-spatial-resolution biomagnetism imaging. While micro-fabricated vapor cell with only two transparent windows (due to planar nano fabrication processes) has become the major obstacle to achieve double-beam scheme on chip. In this study, an ultra-compact on-chip double-beam scheme based on emerging metasurface is proposed for SERF atomic magnetometer application. With in-surface incident both pump light and probe light, this planar device enables optical-path manipulation of linearly-polarized probe beam to precise intersect with pump beam. Our method supports angle manipulation of probe light up to 45 degrees with efficiencies reaching 70%. The device is designed with silicon nitride with thickness of 0.6 um, which can be directly fabricated on the transparent window of vapor cell through basic CMOS compatible processes. In addition, there are more advantages of this method including dramatic volume reduction and potential low-cost mass fabrication, which is promising for future applications including high-resolution biomagnetism imaging and portable atomic devices.
引用
收藏
页数:5
相关论文
共 45 条
  • [41] Ultra-broadband on-chip beam focusing enabled by GRIN metalens on silicon-on-insulator platform
    Shen, Jian
    Zhang, Yong
    Dong, Yihang
    Xu, Zihan
    Xu, Jian
    Quan, Xueling
    Zou, Xihua
    Su, Yikai
    NANOPHOTONICS, 2022, 11 (16) : 3603 - 3612
  • [42] Measurement of uranium isotope ratio in solid sample by laser ablation and double-beam diode laser atomic absorption
    Liu, HT
    Zhang, ZX
    Quentmeier, A
    Niemax, K
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (10) : 1244 - 1247
  • [43] Integrated optical rotation detection scheme for chip-scale atomic magnetometer empowered by silicon-rich SiNx metalens
    Hu, Jinsheng
    Liang, Zihua
    Zhou, Peng
    Liu, Lu
    Hu, Gen
    Du, Pengcheng
    Ye, Mao
    OPTICS LETTERS, 2024, 49 (12) : 3364 - 3367
  • [44] ON THE ACCURACY OF THE FLAME-ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF MAIN COMPONENTS .6. COMPARISON BETWEEN SINGLE-BEAM AND DOUBLE-BEAM MEASUREMENTS
    STEGLICH, F
    STAHLBERG, R
    LUFTER, M
    PAWLIK, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 322 (06): : 555 - 562
  • [45] COMPUTER-CONTROLLED GEOCHEMICAL ANALYSIS SYSTEM FOR USE WITH EXISTING PERKIN ELMER DOUBLE-BEAM ATOMIC-ABSORPTION SPECTROPHOTOMETERS
    BRISTOW, Q
    JOURNAL OF GEOCHEMICAL EXPLORATION, 1975, 4 (03) : 371 - 383