Determination of thymol using HPLC-ED with glassy carbon paste electrode

被引:0
|
作者
Zima, Jiri [1 ]
Cienciala, Miroslava [1 ]
Barek, Jiri [1 ]
Moreira, Josino C. [2 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Sci, UNESCO Lab Environm Electrochem, Prague 12843, Czech Republic
[2] Fiocruz MS, CESTEH, BR-21045900 Rio De Janeiro, Brazil
来源
CHEMIA ANALITYCZNA | 2007年 / 52卷 / 06期
关键词
thymol; HPLC-ED; amperometric detection; glassy carbon paste electrode;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of glassy carbon electrodes (CPE) for the determination of tymol was studied. The amperometric detection with prior separation of tymol by HPLC is proposed. The optimum conditions have been found. The HPLC-ED limit of detection of tymol at + 1.1 V vs Ag/AgCl/3 mol L-1 KCl in the mobile phase consisting of diluted Britton-Robinson buffer pH 7-methanol 1:9 (v/v) was 2.9 x 10(-7) mol L-1 which was lower than that with UV detection at 276 ran. The repeatability of the new method for the determination of thymol using HPLC with amperometric detection, expressed as the relative standard deviation, was below 2% when the areas of the peaks were evaluated and below 5% when the peak heights were measured. The practial application of newly developed method of HPLC-FD determination was tested on samples of Septolete pastilles and thyme sirup.
引用
收藏
页码:1049 / 1057
页数:9
相关论文
共 50 条
  • [21] Xanthine oxidase modified glassy carbon paste electrode
    Anik, U
    Timur, S
    Wang, J
    Telefoncu, A
    ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (09) : 913 - 916
  • [22] Comparative Analysis of Antioxidative Activity of Flavonoids Using HPLC-ED and Photometric Assays
    Piszcz, Pawel
    Wozniak, Magdalena
    Asztemborska, Monika
    Glod, Bronislaw K.
    FOOD ANALYTICAL METHODS, 2014, 7 (07) : 1474 - 1480
  • [23] HPLC-ED of low-molecular weight brominated phenols and tetrabromobisphenol A using pretreated carbon fiber microelectrode
    Bartosova, Zdenka
    Jirovsky, David
    Riman, Daniel
    Halouzka, Vladimir
    Svidrnoch, Martin
    Hrbac, Jan
    TALANTA, 2014, 122 : 115 - 121
  • [24] Determination of sulfonamides in milk samples by HPLC with amperometric detection using a glassy carbon electrode modified with multiwalled carbon nanotubes
    Maria Bueno, Ana
    Maria Contento, Ana
    Rios, Angel
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (04) : 382 - 389
  • [25] A new sensitive voltammetric determination of thymol based on MnY nanozeolite modified carbon paste electrode using response surface methodology
    Aghamohseni, Behnaz
    Hassaninejad-Darzi, Seyed Karim
    Asadollahi-Baboli, Mohammad
    MICROCHEMICAL JOURNAL, 2019, 145 : 819 - 832
  • [26] Voltammetric Determination of an Anti-rheumatoid Drug Acemetacin on Graphite Flake Paste Electrode and Glassy Carbon Electrode
    Festinger, Natalia
    Smarzewska, Sylwia
    Mirceski, Valentin
    Ciesielski, Witold
    ELECTROANALYSIS, 2021, 33 (02) : 314 - 322
  • [27] Determination of gold using clay modified carbon paste electrode
    Navrátilová, Z
    Kula, P
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (04): : 369 - 372
  • [28] Determination of gold using clay modified carbon paste electrode
    Z. Navrátilová
    Petr Kula
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 369 - 372
  • [29] Voltammetric Oxidation and Determination of Atenolol Using a Carbon Paste Electrode
    Patil, Roopa H.
    Hegde, Rajesh N.
    Nandibewoor, S. T.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (23) : 10206 - 10210
  • [30] Electrochemical Oxidation and Determination of Nimesulide Using a Carbon Paste Electrode
    Malode, Shweta J.
    Nandibewoor, Sharanappa T.
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2013, 227 (01): : 73 - 87