EVALUATION OF HEAT TRANSFER COEFFICIENTS IN VARIOUS AIR-CONDITIONING MODES BY USING THERMAL MANIKIN

被引:0
|
作者
Lee, Sihwan [1 ]
Nogami, Mai [1 ]
Yamaguchi, Satomi [1 ]
Kurabuchi, Takashi [1 ]
Ohira, Noboru [2 ]
机构
[1] Tokyo Univ Sci, Dept Architecture, Tokyo, Japan
[2] Tokyo Gas Co Ltd, Facil Engn Grp, Tokyo, Japan
关键词
PREDICTING FLUID-FLOW; FIELD CALCULATIONS; REATTACHING FLOWS; TURBULENCE MODEL;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Today, radiant floor heating systems are generally used for heating indoor environments of residential buildings. Radiant heating is physically comfortable and energy use largely differs compared to convective heating. It is believed that one reason for that is if there is an air flow, there is a difference in surface heat transfer of the human body. The heat transfer coefficient of the human body is an indispensable parameter to evaluate the indoor thermal environment, thermal comfort and heat loads in airconditioned and ventilated buildings. Measuring the heat transfer coefficient of the human body under various airconditioning conditions is rather difficult due to the multitude of factors, such as temporal changes in air temperature, airflow, cold draft, ventilation condition, storage effect, heat due to radiation, etc. Considering the above, in order to measure surface heat transfer precisely, an expensive thermal manikin or highly controlled environment laboratory is necessary. For this, recent developed computational fluid dynamics (CFD) are suitable. With the objectivity of prediction results and the degree of freedom of condition settings, they are able to become a beneficial investigative method. The purpose of this paper is to verify the heat transfer coefficient of the human body and operative temperature in various air-conditioning environments, such as radiant floor heating and convective air heating using numerical simulation for evaluation of energy saving possibility in residential buildings. First, we measure the heat transfer coefficient of the human body using a thermal manikin in an experimental chamber under natural convection conditions. Then, to confirm CFD calculation accuracy, heat transfer coefficient of the thermal manikin with a temperature difference is verified using an experimental chamber model. Second, we measure the heat transfer coefficient of the thermal manikin surface with CFD calculation to verify its characteristics under forced convection conditions. Finally, we evaluate the operative temperature in an air-conditioned room using computer fluid dynamics to propose the correlation relation in various air-conditioning modes for residential buildings. The measured results showed the heat transfer coefficient of the thermal manikin increased from temperature difference increase and air velocity. Furthermore, the results showed the radiant floor heating environment is more energy consumption efficient than a convective air heating environment.
引用
收藏
页码:2289 / 2296
页数:8
相关论文
共 50 条
  • [21] THERMAL ENVIRONMENT IN AN AIR-CONDITIONING LABORATORY
    Qiu, Lin
    Guo, Kui
    Wei, Lifeng
    Ren, Geng
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 909 - 914
  • [22] Heat transfer performance of flat heat pipe based on air-conditioning energy recovery
    Xiahou, Guowei
    Xie, Mingfu
    Kong, Fangming
    Yang, Caiyun
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2015, 46 (01): : 317 - 323
  • [23] LCCP Evaluation on Environmental Impact of Air-conditioning Cold and Heat Source
    Wang, Zhi Yong
    Wang, Han Qing
    Liu, Chang Rong
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 1789 - 1794
  • [24] Influence of the process and regeneration air conditions on the thermal performance of various desiccant air-conditioning systems
    Omar, Hani
    Sajjad, Uzair
    Hussain, Imtiyaz
    Bhat, Showkat Ahmad
    Sultan, Muhammad
    Ali, Hafiz Muhammad
    Hamid, Khalid
    Yan, Wei-Mon
    ENERGY CONVERSION AND MANAGEMENT-X, 2024, 22
  • [25] PERFORMANCE EVALUATION OF AIR-CONDITIONING UNITS
    ALBASSAM, E
    MAHESHWARI, GP
    RENEWABLE ENERGY, 1994, 4 (07) : 873 - 878
  • [26] Heat recovery in an air-conditioning system with air-to-air heat exchanger
    Papakostas, K. T.
    Kiosis, G. C.
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2015, 34 (3-4) : 221 - 231
  • [27] Heat recovery in an air-conditioning system with air-to-air heat exchanger
    Papakostas, K.T.
    Kiosis, G.C.
    International Journal of Sustainable Energy, 2015, 34 : 221 - 231
  • [28] Effect of Coolant Temperature on the Condensation Heat Transfer in Air-Conditioning and Refrigeration Applications
    Alhajeri, M. H.
    Koluib, A. M.
    Alajmi, R.
    Kalim, S. P.
    EXPERIMENTAL HEAT TRANSFER, 2009, 22 (01) : 58 - 72
  • [29] Influence of position and way of air-conditioning heat release on outdoor thermal environment
    Huang, H
    Ooka, R
    Kato, S
    Harayama, K
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 540 - 546
  • [30] Metal hydride heat pump and air-conditioning
    Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200030, China
    不详
    Taiyangneng Xuebao, 2006, 3 (314-320):