EVALUATION OF HEAT TRANSFER COEFFICIENTS IN VARIOUS AIR-CONDITIONING MODES BY USING THERMAL MANIKIN

被引:0
|
作者
Lee, Sihwan [1 ]
Nogami, Mai [1 ]
Yamaguchi, Satomi [1 ]
Kurabuchi, Takashi [1 ]
Ohira, Noboru [2 ]
机构
[1] Tokyo Univ Sci, Dept Architecture, Tokyo, Japan
[2] Tokyo Gas Co Ltd, Facil Engn Grp, Tokyo, Japan
关键词
PREDICTING FLUID-FLOW; FIELD CALCULATIONS; REATTACHING FLOWS; TURBULENCE MODEL;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Today, radiant floor heating systems are generally used for heating indoor environments of residential buildings. Radiant heating is physically comfortable and energy use largely differs compared to convective heating. It is believed that one reason for that is if there is an air flow, there is a difference in surface heat transfer of the human body. The heat transfer coefficient of the human body is an indispensable parameter to evaluate the indoor thermal environment, thermal comfort and heat loads in airconditioned and ventilated buildings. Measuring the heat transfer coefficient of the human body under various airconditioning conditions is rather difficult due to the multitude of factors, such as temporal changes in air temperature, airflow, cold draft, ventilation condition, storage effect, heat due to radiation, etc. Considering the above, in order to measure surface heat transfer precisely, an expensive thermal manikin or highly controlled environment laboratory is necessary. For this, recent developed computational fluid dynamics (CFD) are suitable. With the objectivity of prediction results and the degree of freedom of condition settings, they are able to become a beneficial investigative method. The purpose of this paper is to verify the heat transfer coefficient of the human body and operative temperature in various air-conditioning environments, such as radiant floor heating and convective air heating using numerical simulation for evaluation of energy saving possibility in residential buildings. First, we measure the heat transfer coefficient of the human body using a thermal manikin in an experimental chamber under natural convection conditions. Then, to confirm CFD calculation accuracy, heat transfer coefficient of the thermal manikin with a temperature difference is verified using an experimental chamber model. Second, we measure the heat transfer coefficient of the thermal manikin surface with CFD calculation to verify its characteristics under forced convection conditions. Finally, we evaluate the operative temperature in an air-conditioned room using computer fluid dynamics to propose the correlation relation in various air-conditioning modes for residential buildings. The measured results showed the heat transfer coefficient of the thermal manikin increased from temperature difference increase and air velocity. Furthermore, the results showed the radiant floor heating environment is more energy consumption efficient than a convective air heating environment.
引用
下载
收藏
页码:2289 / 2296
页数:8
相关论文
共 50 条
  • [1] Application of the thermal manikin for ventilation and air-conditioning system assessment
    Chludzinska, M.
    Mizielinski, B.
    Bogdan, A.
    ENVIRONMENTAL ENGINEERING III, 2010, : 121 - 126
  • [2] SYSTEM EVALUATION OF HEAT-PUMPS OPERATED IN BOTH HEATING AND AIR-CONDITIONING MODES
    SERGISON, J
    WICKS, F
    BECKER, M
    MULLIGAN, G
    YERAZUNIS, S
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (03): : 1012 - 1020
  • [3] THERMAL MODEL FOR EVALUATION OF SUBWAY VENTILATION AND AIR-CONDITIONING
    LASSOW, W
    SCHOCH, KF
    LUSTENADER, EL
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1972, IA 8 (04) : 504 - +
  • [4] Heat insulation in air-conditioning
    Heilman, RH
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1936, 28 : 782 - 786
  • [5] THERMAL PERFORMANCE ENHANCEMENT OF HEAT PIPE HEAT EXCHANGER IN THE AIR-CONDITIONING SYSTEM BY USING NANOFLUID
    Abdallah, Ayad S.
    Yasin, Nabil Jamil
    Ameen, Hani Aziz
    FRONTIERS IN HEAT AND MASS TRANSFER, 2022, 18
  • [6] Determination of convective and radiative heat transfer coefficients using 34-zones thermal manikin: Uncertainty and reproducibility evaluation
    Fojtlin, Milos
    Fiser, Jan
    Jicha, Miroslav
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 77 : 257 - 264
  • [7] Evaluation of the Prospects of using Solar Thermal Air-Conditioning Systems in Saudi Arabia
    Mazharul, Islam
    Muhammad, Ruhul Amin
    Farid, Nasir Ani
    MECHANICAL AND MATERIALS ENGINEERING, 2014, 554 : 271 - +
  • [8] Enhancement of the air quality and heat transfer rate of an air-conditioning system using a hybrid polypropylene nanofilter
    Haider, Adawiya J.
    Sukkar, Khalid A.
    Abdalsalam, Alyaa H.
    Ali, Adnan F.
    Jaber, Salah H.
    Ridha, Thaer T. Abdul
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 149 : 56 - 66
  • [9] Evaluation of combined heat and mass transfer effect on the thermoeconomic optimization of an air-conditioning rotary regenerator
    Jassim, Rahim K.
    Journal of Heat Transfer, 2003, 125 (04): : 724 - 733
  • [10] Match properties of heat transfer and coupled heat and mass transfer processes in air-conditioning system
    Zhang, Tao
    Liu, Xiao-Hua
    Zhang, Lun
    Jiang, Yi