An Artificial Lens Capsule with a Lens Radial Stretching System Mimicking Dynamic Eye Focusing

被引:3
|
作者
Wei, Huidong [1 ,2 ]
Wolffsohn, James S. [1 ]
Gomes de Oliveira, Otavio [2 ]
Davies, Leon N. [1 ]
机构
[1] Aston Univ, Coll Hlth & Life Sci, Birmingham B4 7ET, W Midlands, England
[2] Rayner Intraocular Lenses Ltd, Worthing BN14 8AQ, England
关键词
presbyopia; accommodation; AIOL; ALC; LRSS; HUMAN CILIARY MUSCLE; MECHANICAL-PROPERTIES; ELASTIC-CONSTANTS; ACCOMMODATION; AGE; SHAPE; FORCE; RESTORATION; MEMBRANE; LOCATION;
D O I
10.3390/polym13203552
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Presbyopia is a common eye disorder among aged people which is attributed to the loss of accommodation of the crystalline lens due to the increasing stiffness. One of the potential techniques to correct presbyopia involves removing the lens substance inside the capsule and replacing it with an artificial lens. The development of such devices, e.g., accommodating intraocular lenses (AIOLs), relies on the understanding of the biomechanical behaviour of the lens capsule and the essential design verification ex vivo. To mimic the eye's dynamic focusing ability (accommodation), an artificial lens capsule (ALC), from silicone rubber accompanied by a lens radial stretching system (LRSS) was developed. The ALC was manufactured to offer a dimension and deforming behaviour replicating the human lens capsule. The LRSS was calibrated to provide a radial stretch simulating the change of diameter of capsules during accommodating process. The biomechanical function of the ALC was addressed by studying its evolution behaviour and reaction force under multiaxial stretch from the LRSS. The study highlighted the convenience of this application by performing preliminary tests on prototypes of ophthalmic devices (e.g., AIOLs) to restore accommodation.</p>
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Improvement of the Scanning Performance of the Extended Hemispherical Integrated Lens Antenna Using a Double Lens Focusing System
    Nguyen, N. T.
    Boriskin, A. V.
    Le Coq, L.
    Sauleau, R.
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2016, 64 (08) : 3698 - 3702
  • [42] Human Anterior Lens Capsule as an Artificial Descemet Membrane Substrate in Corneal Surgery
    Kopsachilis, N.
    Welge-Luessen, U.
    Kruse, F. E.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [43] IMPLANTATION OF A POSTERIOR CHAMBER ARTIFICIAL LENS SUTURED TO THE IRIS IN THE ABSENCE OF POSTERIOR CAPSULE
    COLIN, J
    DESCHAMPS, F
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 1992, 15 (03): : 227 - 227
  • [44] ISOELECTRIC FOCUSING OF LENS CRYSTALLINS IN THIN-LAYER POLYACRYLAMIDE GELS - METHOD FOR DETECTION OF SOLUBLE PROTEINS IN EYE LENS EXTRACTS
    BOURS, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1971, 60 (02): : 225 - &
  • [45] Acoustic vortex-based dynamic lens for light focusing and steering
    Hu, Chia-Wen
    Hsieh, Zong-Han
    Huang, Chung-Han
    Li, Meng-Lin
    Yeh, Chih-Kuang
    [J]. Optics Letters, 2024, 49 (21) : 6341 - 6344
  • [46] THE MECHANISM ALIGNING THE LENS WITH THE REST OF THE OPTICAL SYSTEM OF THE EYE
    COULOMBRE, JL
    COULOMBRE, AJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY, 1964, 3 (04): : 478 - 478
  • [47] Design on internal focusing optical system with zoom lens of freeform
    Jiang T.
    Feng H.
    Li Q.
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2021, 50 (04):
  • [48] Lens-based collection system for a proximity focusing RICH
    Pestotnik, R
    Bizjak, I
    Gorisek, A
    Korpar, S
    Krizan, P
    Staric, M
    Stanovnik, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3): : 237 - 239
  • [49] RADIAL ION-BEAM FOCUSING IN A MAGNETIC ANALYZER WITH INHOMOGENEOUS FIELD AND ELECTROSTATIC LENS
    KUZEMA, AS
    ZINCHENKO, NS
    SAVIN, OR
    [J]. ZHURNAL TEKHNICHESKOI FIZIKI, 1977, 47 (11): : 2368 - 2371
  • [50] LENS EPITHELIAL-CELL ADHESION TO LENS CAPSULE - A MODEL SYSTEM FOR CELL BASEMENT-MEMBRANE INTERACTION
    CAMMARATA, PR
    SPIRO, RG
    [J]. JOURNAL OF CELLULAR PHYSIOLOGY, 1982, 113 (02) : 273 - 280