Variability in the analysis of 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry: The devil is in the detail

被引:52
|
作者
Couchman, Lewis [1 ]
Benton, Christopher M. [1 ]
Moniz, Cajetan F. [1 ]
机构
[1] Kings Coll Hosp NHS Fdn Trust, Dept Clin Biochem, London SE5 9RS, England
关键词
25-Hydroxyvitamin D; LC-MS/MS; Standardisation; DEQAS; VITAMIN-D STATUS; CIRCULATING; 25-HYDROXYVITAMIN-D; SAMPLE PREPARATION; LC-MS/MS; D ASSAYS; ACCURACY; SERUM; BIOANALYSIS; METABOLITES; INFANTS;
D O I
10.1016/j.cca.2012.04.003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is increasingly used in clinical laboratories for the analysis of 25-hydroxyvitamin D (25OHD), but measurement is not straightforward. Importantly. LC-MS/MS is not a single technique: variables in sample preparation, chromatography and ionisation/fragmentation should each be considered. Methods: We analysed results from a survey organised by the international Vitamin D External Quality Assessment Scheme (DEQAS), to determine the influence of such variables on the results for two DEQAS distributions. Results: 65 laboratories returned questionnaires. 346 (57%) individual results were from laboratories using electrospray ionisation (ESI), and 259 (43%) from laboratories using atmospheric pressure chemical ionisation (APCI). Although the mean ratio of results was not significantly different between ESI and APCI (P = 0.5828), there was greater variation (P<0.0001) in results obtained by laboratories using ESI. Greater variation (P<0.05) was also observed between results from laboratories monitoring non-specific water-loss transitions. Only 3 laboratories (5%) could resolve the isobaric metabolite 3-epi-25OHD(3) from 25OHD(3). Conclusions: There are many variables to consider when using LC-MS/MS, including assay standardisation/calibration, chromatography and MS conditions. MS/MS alone cannot distinguish isobaric metabolites such as 3-epi-25OHD(3). Interference can also occur if non-specific transitions are used. Laboratories should always subscribe to an EQA scheme for 25OHD analysis. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1239 / 1243
页数:5
相关论文
共 50 条
  • [31] Rapid Analysis of 25-Hydroxyvitamin D2 and D3 by Liquid Chromatography-Tandem Mass Spectrometry and Association of Vitamin D and Parathyroid Hormone Concentrations in Healthy Adults
    Kushnir, Mark M.
    Ray, Julie A.
    Rockwood, Alan L.
    Roberts, William L.
    La'ulu, Sonia L.
    Whittington, JoDell E.
    Meikle, A. Wayne
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2010, 134 (01) : 148 - 156
  • [33] A simple automated solid-phase extraction procedure for measurement of 25-hydroxyvitamin D3 and D2 by liquid chromatography-tandem mass spectrometry
    Knox, Susan
    Harris, John
    Calton, Lisa
    Wallace, A. Michael
    ANNALS OF CLINICAL BIOCHEMISTRY, 2009, 46 : 226 - 230
  • [34] Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method
    Chen, Huiping
    McCoy, Leslie F.
    Schleicher, Rosemary L.
    Pfeiffer, Christine M.
    CLINICA CHIMICA ACTA, 2008, 391 (1-2) : 6 - 12
  • [35] Analysis of vitamin D metabolites by liquid chromatography-tandem mass spectrometry
    van den Ouweland, Johannes M. W.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 84 : 117 - 130
  • [36] Measurement of serum 3-epi-25-hydroxyvitamin D3, 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in infant, paediatric and adolescent populations of Korea using ultra-performance liquid chromatography-tandem mass spectrometry
    Cho, Sung E.
    Kim, Sollip
    Kim, Young D.
    Lee, Hyojung
    Seo, Dong H.
    Song, Junghan
    Um, Tae H.
    Cho, Chong R.
    Kim, Nam H.
    Hwang, Jong H.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2017, 54 (05) : 530 - 538
  • [37] Use of a common standard improves the performance of liquid chromatography-tandem mass spectrometry methods for serum 25-hydroxyvitamin-D
    Carter, Graham D.
    Jones, Julia C.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2009, 46 : 79 - 81
  • [38] Simultaneous quantification of 25-hydroxyvitamin D3-3-sulfate and 25-hydroxyvitamin D3-3-glucuronide in human serum and plasma using liquid chromatography-tandem mass spectrometry coupled with DAPTAD-derivatization
    Gao, Chunying
    Bergagnini-Kolev, Mackenzie C.
    Liao, Michael Z.
    Wang, Zhican
    Wong, Timothy
    Calamia, Justina C.
    Lin, Yvonne S.
    Mao, Qingcheng
    Thummel, Kenneth E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1060 : 158 - 165
  • [39] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [40] Removal of 3-Epi-25-Hydroxyvitamin D3 Interference by Liquid Chromatography-Tandem Mass Spectrometry Is Not Required for the Measurement of 25-Hydroxyvitamin D3 in Patients Older than 2 Years
    Wright, Michael J. P.
    Halsall, David J.
    Keevil, Brian G.
    CLINICAL CHEMISTRY, 2012, 58 (12) : 1719 - 1720